1. Introducció i finalview
The EPEVER MT52 Remote Meter is designed to work with EPEVER solar charge controllers that feature RS485 communication. It allows users to monitor the controller's real-time working status and program various parameters.
Característiques principals:
- Fàcil d'instal·lar i operar.
- Real-time display of fault alarms.
- Locally reading of real-time parameters.
- Powered directly by the controller.
- Equipped with an RJ45 communication port.

Visual representation of the MT52's main features.
2. Instruccions de seguretat importants
Please read and follow these instructions carefully to ensure safe operation and prevent damage to the device.
- Inspect the MT52 thoroughly upon delivery. Report any damage to the shipping company or manufacturer immediately.
- Read all instructions and cautions in this manual before installation.
- Keep the MT52 away from rain, direct exposure, severe dust, vibrations, corrosive gases, and intense electromagnetic interference.
- Prevent water from entering the remote meter.
- The remote meter contains no user-serviceable parts. Do not disassemble or attempt to repair it.
3. Instal·lació
3.1. Frame Mount Dimensions
The following diagram illustrates the dimensions for frame mounting the MT52 remote meter.

Davant i posterior views of the MT52 with key components labeled.

Davant i darrere views of the MT52 remote meter and its mounting frame.
| Paràmetre mecànic | Paràmetre |
|---|---|
| Dimensió global | 114 mm x 114 mm x 48.2 mm |
| Dimensió de muntatge | 84 mm x 84 mm |
| Dimensió del forat del cargol | Φ5 |
3.2. Muntatge a la paret
- Pas 1: Localitzeu i perforeu forats per als cargols segons la dimensió de muntatge del marc de la base i instal·leu els cargols d'expansió de plàstic.
- Pas 2: Fix the frame with four ST4.2×3 self-tapping cross recessed pan head screws.
- Pas 3: Use four M4×8 pan head screws to mount the MT52 panel on the frame.
- Pas 4: Munteu els quatre taps de rosca associats als forats dels cargols.

Illustrations for wall mounting the MT52 remote meter.
3.3. Mounting on the Panel Surface
- Pas 1: Localitzeu i perforar els forats dels cargols en funció de la mida d'instal·lació de la superfície.
- Pas 2: Use four M4×8 cross recessed pan head screws with M4 nuts to mount the MT52 panel onto the surface.
- Pas 3: Munteu els quatre taps de cargol blancs associats als forats dels cargols.

Illustrations for panel surface mounting the MT52 remote meter.
Nota: Tingueu en compte l'espai de connexió/desconnexió i la longitud del cable de comunicació durant la instal·lació.
4. Product Features (Physical Description)
4.1. Davant View

Front detallat view of the MT52 remote meter, highlighting the display screen, failure indicator, communication indicator, and buttons.
4.2. Enrere View

Part posterior detallada view of the MT52 remote meter, showing the RJ45 interface.
| Mòdul | Funció |
|---|---|
| Indicador de fallada | Flashes when a fault occurs. Refer to the controller's user manual for detailed fault information. |
| Indicador de comunicació | Indicates the communication status between the MT52 and the connected controller. |
| Pantalla de visualització | Interfície home-màquina. |
5. Funcionament
5.1. Botons
The MT52 features six buttons: ESC, Left, Up, Down, Right, and OK. Their functions are described below:

Flowchart illustrating the operation of the MT52 remote meter's buttons for navigation and parameter modification.
- The default entry page is the browse mode.
- Premeu el botó OK button and input the correct password to enter modification mode.
- Ús Esquerra i D'acord botons per moure el cursor.
- Ús Up i Avall buttons to modify parameter values.
- Premeu OK to confirm changes and ESC cancel·lar.
5.2. Menú principal
Entra al menú principal prement ESC. Ús Up i Avall buttons to select menu items, and OK or ESC to enter or exit pages.

Flowchart showing the main menu structure of the MT52 remote meter.
- Seguiment
- Informació del dispositiu.
- Prova de funcionament
- Control Paràgraf.
- Conjunt de càrrega
- Paràgraf del dispositiu
- Dispositiu PSW.
- Restabliment de fàbrica
- Informació de fallada.
- Metre Paràgraf.
5.3. Monitorització en temps real
The real-time monitoring section provides 13 pages of data. Navigate using the Up i Avall buttons to move between rows, and Esquerra or D'acord buttons to move along a row.

First part of the real-time monitoring screens, showing charge/discharge energy and battery status.

Second part of the real-time monitoring screens, showing PV, controller, and load status.
| Nom | Pantalla LCD | Instrucció |
|---|---|---|
| Icones de dia i de nit | 🌙 / ☀️ | Night / Day (Day when PV voltage > 1 V) |
| Icona de corrent de càrrega | ≫≫≫ | Dynamically running when there is a charge current. |
| Icona de la bateria | 🔋 | Dynamically displayed battery capacity. Shows ❌ when over-discharged. |
| Icones d'estat de la bateria | 😊 / 😐 / 😠 | Volum de bateria normaltage / Battery under voltage / Battery over-discharge |
| Carrega la icona actual | ≫≫≫ | Dynamically running when there is a discharge current. |
| Icona d'estat de càrrega | 💡 / 🔌 | Load On / Load Off. In Manual Mode, press OK to switch load. |
| Valors de volum i corrent de PV | e.g., 17.5V 15.2A | Mostra el volum PVtage i valors actuals. |
| Battery vol. and cur. values | e.g., 13.8V 5.2A | Mostra el volum de la bateriatage i valors actuals. |
| Load vol. and cur. values | e.g., 13.8V 10.0A | Mostra el volum de càrregatage i valors actuals. |
5.4. Informació del dispositiu
This page displays the connected controller's parameters.
| Paràmetre | Valor |
|---|---|
| Rate.Vol | 12 V |
| Char.Cur | 10.0A |
| Disc.Cur | 2.6A |
Consells operatius:
- Ús Up i Avall buttons to browse pages.
5.5. Prova de funcionament
A load switch test can be performed to check if the load output is normal. This test does not affect the actual load settings. The solar controller will exit test mode upon exiting this page.
Prova de funcionament
LS****B: OFF
Consells operatius:
- Enter the page and input the correct password.
- Ús Up i Avall buttons to modify the On/Off status.
- Premeu OK per confirmar i ESC cancel·lar.
5.6. Control Parameter
Browse and modify the control parameters of the solar controller. Refer to the control parameters table for the scope of modification.

Flowchart illustrating the control parameter modification process.
5.6.1. Tipus de bateria
Supported battery types include Sealed, Gel, Flooded, Lithium (LiFePO4, Li(NiCoMn)O2), and User-defined.
| Sèrie de productes | Tipus de bateria | Tipus d'interfície | Comunicació |
|---|---|---|---|
| LS-B, GM-N, VS-BN, Tracer-BN | Lead-acid battery, user define | RJ45 | RS485 |
| iTracer-AD/ND | Lead-acid battery, user define | 3.81-4P | |
| Tracer-BP, Tracer-CPN | Bateria de plom-àcid, bateria de liti, definida per l'usuari | Port impermeable RS485 | |
| Tracer-AN (10A~40A), Tracer-AN(50A~100A), Tracer-AN G3, TRIRON, XTRA-N, XTRA-N G3 | Bateria de plom-àcid, bateria de liti, definida per l'usuari | RJ45 |
Nota:
- When the MT52 is connected with different devices, the configurable battery types are listed in the table above. For detailed battery types and setting methods, refer to chapter 4.6 Control parameter in the full manual.
- No instal·leu l'MT52 en una situació amb fortes interferències electromagnètiques.
- The MT52 comes standard with an RS485 communication cable (CC-RS485-RS485-200U). If connecting to a controller with a non-standard RJ45 interface, purchase an appropriate communication cable in advance.
5.6.2. Parameters of Batt. AH, Temp Comp. Coeff and Rated Voltage
| Paràmetre | Per defecte | Interval |
|---|---|---|
| Capacitat de la bateria (AH) | 200 Ah | 1 a 9999 Ah |
| Temp Comp. Coeff (Temperature compensation coefficient) | -3mV°C/2V | 0 to -9mV/°C/2V |
| Voltage | Automàtic | Automàtic/12V/24V/36V/48V |
Nota:
- When the battery type is selected as a lithium battery, the "Temp Comp. Coeff" and "Rated Voltage" cannot be set. The software automatically enables the protection function of "Low temperature prohibits charge and discharge."
5.6.3. Bateria Voltage Parameters (12V/25°C)
Double values for 24V systems, multiply by 4 for 48V systems.
| Configuració de la càrrega de la bateria | Segellat | Gel | Inundat | Usuari |
|---|---|---|---|---|
| Més de voltagi desconnectar voltage | 16.0 V | 16.0 V | 16.0 V | 9~17V |
| Límit de càrrega voltage | 15.0 V | 15.0 V | 15.0 V | 9~17V |
| Més de voltagi reconnectar voltage | 15.0 V | 15.0 V | 15.0 V | 9~17V |
| Equalitzar el volum de càrregatage | 14.6 V | --- | 14.8 V | 9~17V |
| Augmentar la càrrega voltage | 14.4 V | 14.2 V | 14.6 V | 9~17V |
| Volum de càrrega flotanttage | 13.8 V | 13.8 V | 13.8 V | 9~17V |
| Volum de càrrega de reconnexió impulsivatage | 13.2 V | 13.2 V | 13.2 V | 9~17V |
| Vol baixtagi reconnectar voltage | 12.6 V | 12.6 V | 12.6 V | 9~17V |
| Sota el voltage warning reconnect voltage | 12.2 V | 12.2 V | 12.2 V | 9~17V |
| Sota el voltage advertència voltage | 12.0 V | 12.0 V | 12.0 V | 9~17V |
| Vol baixtagi desconnectar voltage | 11.1 V | 11.1 V | 11.1 V | 9~17V |
| Límit de descàrrega voltage | 10.6 V | 10.6 V | 10.6 V | 9~17V |
| Igualar la durada | 120 min | --- | 120 min | 0 ~ 180 min |
| Augmenta la durada | 120 min | 120 min | 120 min | 10 ~ 180 min |
Logic for User-defined Battery Voltage Paràmetres:
- Més del voltage Desconnectar Voltage > Límit de càrrega Voltage ≥ Equalitzar Volum de càrregatage ≥ Augment del volum de càrregatage ≥ Volum de càrrega flotanttage > Boost Reconnect Vol. de càrregatage.
- Més del voltage Desconnectar Voltage > Over Voltage Reconnect Voltage.
- Volum baixtage Reconnect Voltage > Vol baixtage Desconnectar Voltage ≥ Límit de descàrrega Voltage.
- Sota el voltage Warning Reconnect Voltage > Sota el voltage Advertència Voltage ≥ Límit de descàrrega Voltage.
- Boost Reconnect Vol. de càrregatage > Vol baixtage Reconnect Voltage.
5.6.4. Lithium Battery Voltage Paràmetres
For LFP4S, parameters under "User" battery type are 9~17V. Multiply by 2 for LFP8S, and by 4 for LFP15S/LFP16S.
| Paràmetres de la bateria | LFP4S | LFP8S | LFP15S | LFP16S | Usuari |
|---|---|---|---|---|---|
| Més de voltagi desconnectar voltage | 14.8 V | 29.6 V | 55.5 V | 59.2 V | 9~17V |
| Límit de càrrega voltage | 14.6 V | 29.2 V | 54.7 V | 58.4 V | 9~17V |
| Més de voltagi reconnectar voltage | 14.6 V | 29.2 V | 54.7 V | 58.4 V | 9~17V |
| Equalitzar el volum de càrregatage | 14.5 V | 29.0 V | 54.3 V | 58.0 V | 9~17V |
| Augmentar la càrrega voltage | 14.5 V | 29.0 V | 54.3 V | 58.0 V | 9~17V |
| Volum de càrrega flotanttage | 13.8 V | 27.6 V | 51.7 V | 55.2 V | 9~17V |
| Augmenta el volum de càrrega de reconnexiótage | 13.2 V | 26.4 V | 49.5 V | 52.8 V | 9~17V |
| Vol baixtagi reconnectar voltage | 12.8 V | 25.6 V | 48.0 V | 51.2 V | 9~17V |
| Sota el voltage warning reconnect voltage | 12.2 V | 24.4 V | 45.7 V | 48.8 V | 9~17V |
| Sota el voltage advertència voltage | 12.0 V | 24.0 V | 45.0 V | 48.0 V | 9~17V |
| Vol baixtagi desconnectar voltage | 11.1 V | 22.2 V | 41.6 V | 44.4 V | 9~17V |
| Límit de descàrrega voltage | 11.0 V | 22.0 V | 41.2 V | 44.0 V | 9~17V |
Logic for User-defined Lithium Battery Voltage Paràmetres:
- Més del voltage Desconnectar Voltage > Protecció de sobrecàrrega Voltage (BMS) + 0.2V.
- Més del voltage Desconnectar Voltage > Over Voltage Reconnect Voltage = Límit de càrrega Voltage ≥ Equalitzar Volum de càrregatage = Volum de càrrega boosttage ≥ Volum de càrrega flotanttage > Boost Reconnect Vol. de càrregatage.
- Volum baixtage Reconnect Voltage > Vol baixtage Desconnectar Voltage ≥ Límit de descàrrega Voltage.
- Sota el voltage Warning Reconnect Voltage > Sota el voltage Advertència Voltage ≥ Límit de descàrrega Voltage.
- Boost Reconnect Vol. de càrregatage > Vol baixtage Reconnect Voltage.
- Volum baixtage Desconnectar Voltage ≥ Protecció de sobredescàrrega Voltage (BMS) + 0.2V.
5.7. Configuració de càrrega
This page allows setting the four load working modes of the connected solar controller: Manual, Light on/off, Light on + timer, and Time control.

Flowchart showing the different load working modes and their settings.
5.7.1. Control manual
| Mode | Introduccions |
|---|---|
| ON | La càrrega està activada si la capacitat de la bateria és suficient i no es produeixen condicions anormals. |
| OFF | La càrrega està apagada tot el temps. |
5.7.2. Llum Encès/Apagat
| Mode | Introduccions |
|---|---|
| Light On voltage (llindar nocturn) | The load output is automatically turned on when: 1. The PV input voltage és inferior al volum de llum activadatage. 2. La capacitat de la bateria és suficient. 3. No es produeixen condicions anormals. |
| Llum apagada voltage (llindar del dia) | Quan l'entrada PV voltage és més alt que el volum de llum apagadatage, la sortida de càrrega es desactiva automàticament. |
| Temps de retard | The confirmation time for the light signal. If the light signal voltage continua coincidint amb el volum de llum encès/apagattage during this period (0~99mins), the controller will perform corresponding actions. |
5.7.3. Light On + Timer

Diagram illustrating the Light On+Timer load control mode.
| Paràmetre | Descripció |
|---|---|
| Temps de treball 1 (T1) | Load working period after light control turns on the load. |
| Temps de treball 2 (T2) | Load working period before light control turns off the load. |
| De nit | Total night-time by calculation (≥3h). If any working time is set as "0," it means to stop working. The real working time of T2 depends on the night-time and the length of T1, T2. |
5.7.4. Control del temps
| Paràmetre | Descripció |
|---|---|
| Temps de treball 1 (T1) | Controls the on/off time of the load through real-time clock mode. This is the compulsory load working time interval. |
| Temps de treball 2 (T2) | Realizes the dual timer function of the load control through real-time clock mode. This is optional. |
5.8. Paràmetre del dispositiu
Check and modify the meter's model, software, and hardware version, as well as switch pages and backlight settings.
Metre Paràgraf.
Type: MT52
Versió: V1.00+V1.00
Metre Paràgraf.
Sw-Pàgines: 000S
Bklight: 020S
AudiAlam: OFF
Nota:
- The bigger the connection device's ID value, the longer the communication identification interval will be (maximum <6 minutes).
- Per obtenir instruccions detallades sobre els paràmetres del dispositiu, consulteu el manual del controlador solar corresponent.
- To enter the language selection page, long-press Esquerra + Up + Avall + D'acord at the same time on any page.
| Tipus | Notes |
|---|---|
| Ver | Solar controller's software and hardware version numbers. |
| ID | Solar controller's communication ID numbers. |
| Bklight | Solar controller's LCD backlight. |
| Mes-Dia-Any H: M: D | Solar controller's internal clock. |
| Sw-Pàgines | Set the automatic switching interval for the real-time monitoring pages (0~120S). |
| BKlight | Set the LCD backlight time (0~999S). |
| LangSel. | Canvia l'idioma de visualització entre xinès i anglès. |
5.9. Device Password
The solar controller's password can be modified via the device password page. This 6-digit password is required to enter modification modes for "Control parameter," "Load setting," "Device parameter," "Device password," and "Factory reset" pages.
Dispositiu PSW
OriPsw:xxxxxx
NewPsw:xxxxxx
Note: The default password of the solar charge controller is "000000".
5.10. Restabliment de fàbrica
The solar charger controller's default parameters can be restored via the Factory reset page. This includes "Control parameter," "Load setting," "Charge mode," and "Device password." The factory default password is "000000".
Restabliment de fàbrica
Sí No
6. Troubleshooting (Failure Information)
The solar controller's failure information can be checked via the Failure Information page (up to 15 messages). Once failures are resolved, the corresponding information will be automatically cleared.
Informació de fallada
1.Over voltage
2.Over load
3.Short circuit
| Tipus de fallada | Pantalla LCD | Instruccions |
|---|---|---|
| Errors del dispositiu de càrrega | Carregueu MOS-Short | El MOSFET del controlador de càrrega està en curtcircuit. |
| Circuit de càrrega | El circuit de càrrega està en curtcircuit. | |
| Càrrega O. cur. | El circuit de càrrega està sobre corrent. | |
| Entrada O. cur. | Entrada O. cur. | The PV input current exceeds the rated current. |
| RPP curt | The MOSFET of the reverse polarity protection (RPP) is short-circuited. | |
| Pausa RPP | Pausa RPP | The MOSFET of the reverse polarity protection (RPP) breaks. |
| Char. MOS-Short | Char. MOS-Short | El MOSFET del controlador de càrrega està en curtcircuit. |
| Sense alimentació d'entrada | Sense alimentació d'entrada | The input power is not connected successfully. |
| Volum d'entrada alt | Volum d'entrada alt | El volum d’entradatage és molt alta. |
| Input vol. Low | Input vol. Low | El volum d’entradatage és molt baixa. |
| Falla del controlador | Controlador de temperatura O. | El controlador té sobretemperatura. |
| Falla de comunicació | Com. Temps mort | La comunicació és el temps d'espera. |
| Fallades de la bateria | Bat. O. Alta temperatura. | La bateria té una temperatura excessiva. |
| Batt. O. Lo. Temp. | La bateria té una temperatura massa baixa. | |
| Batt. I. R. Eorr | The internal resistance of the battery is in error. | |
| Volum nominal Err. | El voltage està equivocat. | |
| Bat. OVD | La bateria voltage supera el volum superiortagvol. de desconnexió electrònica (OVD)tage valor. | |
| Bat. UVW | La bateria voltage és inferior al vol inferiortagvol. d'avís electrònic (UVW)tage valor. | |
| Bat. LVD | Bat. LVD | La bateria voltage és inferior al vol baixtagvol. de desconnexió (LVD)tage valor. |
| Bat. Err | Bat. Err | El tipus de bateria és incorrecte. |
7. Especificacions tècniques
| Paràmetre | Valor |
|---|---|
| Autoconsum | Il·luminació de fons activada <23mA |
| Il·luminació de fons desactivada <15mA |
| Paràmetre | Valor |
|---|---|
| Dimensió de la placa frontal | 98mm × 98mm |
| Dimensió del marc | 114mm × 114mm |
| Port de comunicació | RJ45 |
| Cable de comunicació (m) | Standard: 2m, Longest: 50 m |
| Pes net | Paquet simple: 0.23 Kg |
| Paquet estàndard: 0.32 kg |
| Paràmetre | Valor |
|---|---|
| Temperatura ambiental | -20°C~+70°C |
7.1. RJ45 Pin Definition

Diagram illustrating the pin definitions for the RJ45 communication cable.
| Pin núm. | Definició |
|---|---|
| 1 | +5~12V Power input |
| 2 | +5~12V Power input |
| 3 | RS485-B |
| 4 | RS485-B |
| 5 | RS485-A |
| 6 | RS485-A |
| 7 | GND |
| 8 | GND |
7.2. Appendix Dimensions

Diagram showing the overall and mounting dimensions of the MT52 remote meter (Unit: mm).
8. Consells d'usuari
- Comprovació de compatibilitat: Abans de la compraasing or connecting, always verify that your EPEVER solar charge controller model is listed as compatible with the MT52. Compatible models include LS-B, GM-N, VS-BN, Tracer-BN, iTracer-AD/ND, Tracer-BP, Tracer-CPN, Tracer-AN series, TRIRON, and XTRA-N series. If you have models like Epever Duoracer or MPPT Dual Battery DR2210N, confirm their RS485 communication and compatibility with the MT52.
- Longitud del cable: While the standard communication cable is 2m, the MT52 supports up to 50m. Ensure you use an appropriate cable length for your installation to avoid signal degradation.
- Seguretat de contrasenya: Remember the default password "000000" for accessing modification modes. Change it if necessary for enhanced security.
9. Garantia i Suport
Procediment de manteniment
If you encounter a fault, first refer to this user manual or contact after-sales personnel for troubleshooting. If factory maintenance is confirmed, send the product to the company via express delivery, prepay the shipping cost, and provide the purchase invoice as proof of warranty.
To facilitate quick warranty service, include the model number, usage environment data, and a detailed description of the fault with the returned product. This information is crucial for addressing your repair needs.
The manufacturer is not responsible for damages caused by improper use or failure to follow this user manual. Maintenance costs incurred during the process will be borne by the customer if the damage is due to misuse.
For the complete and official user manual, please refer to the PDF document: EPEVER MT52 User Manual (PDF)
