Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of the White-Rodgers Fan Control Center, Model 90-118E. This device is designed to manage fan operations in heating, ventilation, and air conditioning (HVAC) systems. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.
Informació de seguretat
ADVERTÈNCIA: Risc de descàrrega elèctrica. Desconnecteu l'alimentació abans de la instal·lació o el manteniment.
- Installation must be performed by a qualified technician in accordance with all local and national electrical codes.
- Ensure the power supply to the HVAC system is completely disconnected before beginning any work.
- Verify all wiring connections are secure and correct to prevent damage to the unit or system.
- No utilitzeu la unitat si alguna part està danyada.
Producte acabatview
The White-Rodgers Fan Control Center 90-118E is a robust component designed for reliable fan control. Key features include:
- Plug-in style relay: Facilitates easy field replacement.
- Pre-stripped, color-coded leads: Simplifica les connexions de cablejat.
- Five combination screw/solder terminals: Per a baix voltagcablejat.
- Standard double-throw relays: Capable of handling both one and two-speed motors.
- Mounting design: Suitable for a 4-inch electrical box.

Figura 1: White-Rodgers Fan Control Center 90-118E. This image shows the control center from an angled perspective, highlighting the metal mounting plate, the central transformer component, and the pre-stripped, color-coded wires neatly bundled and connected to the terminal block.
Instal·lació
Eines necessàries:
- Tornavís (Phillips i/o de punta plana)
- Pelafils/talladors
- Multímetre (per a la verificació)
Passos d'instal·lació:
- Desconnecteu l'alimentació: Turn off the main power supply to the HVAC system at the circuit breaker. Verify power is off using a multimeter.
- Remove Existing Unit (if applicable): Carefully disconnect and remove the old fan control center, noting all wiring connections.
- Mount the New Unit: The 90-118E is designed for mounting in a standard 4-inch electrical box. Secure the unit using appropriate screws.
- Connexions de cable: Connect the pre-stripped, color-coded leads to the corresponding terminals in your HVAC system. Refer to your specific HVAC system's wiring diagram for accurate connections. The unit features five combination screw/solder terminals for low voltagcablejat.
- Relay Installation: The plug-in style relay should be securely seated in its receptacle.
- Verifica les connexions: Double-check all wiring connections for tightness and correctness.
- Restaura l'alimentació: Once all connections are verified, restore power to the HVAC system.
Funcionament
The White-Rodgers Fan Control Center 90-118E operates automatically as an integral part of your HVAC system. It receives signals from the thermostat or other control devices to activate and deactivate the fan motor. Its primary function is to provide reliable switching for fan operations, supporting both single and two-speed motors.
- Upon receiving a call for fan operation (e.g., from a thermostat), the internal relay will energize, closing the appropriate contacts to power the fan motor.
- When the call for fan operation ceases, the relay de-energizes, opening the contacts and turning off the fan motor.
- The double-throw relay design allows for flexible control of different fan motor types and speeds, depending on the system's configuration.
Manteniment
The White-Rodgers Fan Control Center 90-118E is designed for minimal maintenance. Regular inspection by a qualified technician is recommended as part of routine HVAC system checks.
- Inspecció anual: During annual HVAC system servicing, have a technician inspect the control center for any signs of wear, corrosion, or loose connections.
- Neteja: Ensure the unit is free from dust and debris. Use a soft, dry brush or compressed air for cleaning. Do not use liquid cleaners.
- Relay Replacement: The plug-in style relay is designed for easy replacement if it fails. Ensure power is disconnected before attempting to replace the relay.
Resolució de problemes
If you experience issues with your fan control center, refer to the following common troubleshooting steps. For complex issues, contact a qualified HVAC technician.
- El ventilador no s'encén:
- Check if the main power supply to the HVAC system is on.
- Verify the thermostat is calling for fan operation.
- Inspeccioneu les connexions del cablejat per detectar si hi ha fluïdesa o danys.
- Test the relay for continuity (requires a multimeter and electrical knowledge).
- Fan Running Continuously:
- Check if the thermostat is stuck in the "Fan ON" position.
- The relay contacts may be fused closed. The relay may need replacement.
- Intermittent Fan Operation:
- Connexions de cablejat soltes.
- Faulty relay or control board in the HVAC system.
- No Vol baixtage (24V) Output:
- Check the primary 120V input to the control center.
- The internal transformer may be faulty.
Especificacions
| Característica | Especificació |
|---|---|
| Número de model | 90-118E |
| Primary VAC | 120 V |
| Secondary VAC | 24 V |
| Tipus de connector | Endoll |
| Tipus de contacte | Normally Open (SPNO/SPNC) |
| Tipus de muntatge | Plug In Mount (for 4-inch box) |
| Mode d'operació | Automàtic |
| Bobina Voltage | 24 Volts |
| Vol. de commutació màximatage | 24 Volts |
| Dimensions del producte | 1 x 1 x 1 polzades (aproximadament) |
| Pes de l'article | 1.98 lliures (aproximadament) |
| Fabricant | Rodgers blancs |
| País de fabricació | Estats Units |
Garantia i Suport
For warranty information and technical support, please refer to the official White-Rodgers weblloc web o poseu-vos en contacte amb el servei d'atenció al client. Conserveu el rebut de compra per a reclamacions de garantia.
White-Rodgers Customer Service: Visit Emerson.com/contact-us (White-Rodgers is an Emerson brand)