1. Introducció
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Ingersoll Rand 2545K10-P Electric Stationary Air Compressor. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and to prevent personal injury or equipment damage.
2. Informació de seguretat
ADVERTÈNCIA: Si no es segueixen aquestes instruccions de seguretat, es poden produir lesions greus o la mort.
- Desconnecteu sempre l'alimentació abans de realitzar qualsevol manteniment o servei.
- Ensure the compressor is installed in a well-ventilated area to prevent overheating.
- Do not operate the compressor if any parts are damaged or missing.
- Wear appropriate personal protective equipment (PPE) such as eye protection and hearing protection.
- No dirigiu mai aire comprimit cap a vosaltres mateixos ni cap a altres persones.
- Ensure all electrical connections comply with local codes and are properly grounded. The unit requires 230 Volts.
- Regularly inspect the pressure relief valve and tank for signs of corrosion or damage.
3. Producte acabatview
The Ingersoll Rand 2545K10-P is a Type-30 electric-driven, two-stage stationary air compressor designed for heavy shop or industrial use. It delivers reliable performance for various applications including automotive service, fleet maintenance, machine shops, and manufacturing lines. This premium package includes a low oil level switch, an aftercooler, and an automatic tank drain for enhanced functionality and longevity.

Figure 1: Ingersoll Rand 2545K10-P Electric Stationary Air Compressor. This image displays the full compressor unit, highlighting the motor, pump assembly, control panel, and the large vertical air receiver tank with the Ingersoll Rand logo.
4. Configuració
- Desembalatge i inspecció: Carefully remove the compressor from its packaging. Inspect for any shipping damage. Report any damage immediately to the carrier and supplier.
- Ubicació: Place the compressor on a level, stable surface capable of supporting its weight (approximately 1104 pounds). Ensure adequate clearance around the unit for ventilation and maintenance access. Avoid areas with excessive dust or moisture.
- Connexió elèctrica: This compressor requires a 230 Volt, corded electric power source. A qualified electrician must perform all electrical wiring to ensure compliance with local electrical codes and proper grounding. Verify the power supply matches the compressor's requirements before connection.
- Comprovacions inicials: Before first use, check the oil level in the pump. The compressor is typically shipped with oil, but verification is crucial. Refer to the oil sight glass or dipstick.
5. Instruccions de funcionament
- Arrencada del compressor: Ensure all connections are secure and the power supply is connected. Turn the main power switch to the 'ON' position. The compressor will start automatically when the tank pressure drops below the cut-in pressure setting.
- Supervisió de l'operació: Observe the pressure gauge to monitor tank pressure. The compressor is designed to automatically shut off when the maximum pressure (175 PSI) is reached and restart when pressure drops.
- Apagat automàtic: The compressor features an automatic shut-off mechanism to prevent over-pressurization and to conserve energy.
- Apagant: To turn off the compressor, switch the main power switch to the 'OFF' position. It is recommended to drain any accumulated moisture from the air tank after each use or at least daily.
6. Manteniment
Regular maintenance is crucial for the longevity and efficient operation of your air compressor.
- Diari: Drain moisture from the air receiver tank using the automatic tank drain or manual valve. Check the oil level.
- Setmanal/Mensual: Inspect air filters, belts, and hoses for wear or damage. Clean or replace air filters as needed.
- Quarterly/Annually: Change compressor oil. Inspect the pressure relief valve. Check all fasteners for tightness.
For comprehensive maintenance, consider using the Maintenance Kit: 15920081.
7. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El compressor no arrenca | No power, tripped breaker, low oil level switch activated | Check power supply, reset breaker, check and add oil if necessary |
| Baixa pressió d'aire | Air leak, clogged air filter, worn piston rings | Locate and fix leaks, clean/replace air filter, consult service technician |
| Excés de soroll o vibració | Loose components, worn bearings, improper installation | Tighten fasteners, consult service technician for internal issues |
| El compressor funciona contínuament | Pressure switch malfunction, air leak | Inspect pressure switch, check for air leaks |
For issues not listed or if solutions do not resolve the problem, contact customer support.
8. Especificacions
| Característica | Detall |
|---|---|
| Marca | Ingersoll Rand |
| Nom del model | 2545K10-P |
| Número de model de l'article | 45465978 |
| Voltage | 230 Volts |
| Font d'alimentació | Elèctric amb cable |
| Potència màxima | 10 cavalls de potència |
| Potència del motor | 10 cavalls de potència |
| Capacitat de cabal d'aire | 35 peus cúbics per minut (CFM) |
| Pressió màxima | 175 PSI |
| Pes de l'article | 1104 lliures |
| Dimensions del paquet | 82 x 44 x 32 polzades |
| Usos recomanats | Industrial |
| Característiques especials | Automatic Shut-Off, Aftercooler, Automatic Tank Drain, Low Oil Level Switch |
| Components inclosos | Compressor d'aire |
| UPC | 400545000204, 678384659789 |
| Número de part | 958892 |
| Data de primera disponibilitat | 1 de febrer de 2007 |
9. Informació de la garantia
The standard warranty on the reciprocating pump is 1 year. This warranty can be extended to 2 years with the use of the 2yr Warranty Start Up kit (#6131992), which is sold separately. For detailed warranty terms and conditions, please refer to the documentation provided with your purchase or contact Ingersoll Rand customer support.
Optional protection plans are available for purchase, including 3-Year and 4-Year plans, offering extended coverage beyond the manufacturer's warranty.
10. Suport i contacte
If you require technical assistance, have questions regarding operation or maintenance, or need to order replacement parts, please contact Ingersoll Rand customer support. Ensure you have your model number (2545K10-P) and serial number ready when contacting support.
For additional resources and product information, visit the official Ingersoll Rand weblloc.