Sloan 3082675

Sloan Regal 186 Exposed Manual Urinal Flushometer (Model 3082675) Instruction Manual

For models: Regal 186, 3082675

1. Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of the Sloan Regal 186 Exposed Manual Urinal Flushometer, Model 3082675. This flushometer is designed for commercial urinal applications, featuring a 1.0 GPF (Gallons Per Flush) manual flush valve with a non-hold-open handle. It is ADA compliant and constructed with high copper, low zinc brass castings for dezincification resistance, ensuring durability and hygienic operation.

2. Informació de seguretat

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage or injury.

3. Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació.

4. Configuració i instal·lació

This section outlines the general steps for installing the flushometer. Refer to detailed plumbing diagrams for specific configurations.

4.1. Prepare Water Supply

  1. Turn off the main water supply to the fixture.
  2. Flush the urinal to relieve any remaining water pressure.
  3. Ensure the water supply pipe is properly sized (typically 1-1/2" X 3/4" X 9" for the sweat kit).

4.2. Install Bak-Chek Angle Stop

  1. Thread the 3/4" I.P.S. screwdriver Bak-Chek angle stop onto the water supply pipe.
  2. Use pipe sealant or Teflon tape on threads to ensure a watertight seal.
  3. Apretar bé, però no apretar massa.

4.3. Mount Wall Flange

  1. Position the cast wall flange over the angle stop.
  2. Secure the wall flange to the wall using appropriate fasteners (not included) and the provided set screw.

4.4. Connect Flushometer Body

  1. Attach the flushometer body to the angle stop.
  2. Connect the vacuum breaker flush connection to the urinal's top spud.
  3. Assegureu-vos que totes les connexions estiguin estancades i estan ben segellades.
  4. Install the sweat solder adapter and cover tube as required for your specific plumbing setup.

4.5. Comprovacions finals

  1. Enceneu lentament el subministrament d'aigua principal.
  2. Comproveu totes les connexions per detectar fuites.
  3. Adjust the control stop plug to regulate water flow as needed.

5. Instruccions de funcionament

The Sloan Regal 186 Flushometer features a simple manual operation.

5.1. Flushing the Urinal

  1. Locate the ADA compliant metal oscillating non-hold-open handle on the flushometer.
  2. Push the handle down firmly and release. The non-hold-open design ensures a consistent 1.0 GPF flush, promoting water conservation.
  3. The flushometer will automatically reset after the flush cycle is complete.

6. Manteniment

Regular maintenance ensures optimal performance and longevity of your flushometer.

6.1. Neteja

  1. Clean the exterior of the flushometer with a mild, non-abrasive cleaner and a soft cloth.
  2. Avoid using harsh chemicals or abrasive pads, as these can damage the polished chrome finish.

6.2. Diaphragm and Gasket Inspection

  1. Periodically inspect the diaphragm and other internal gaskets for wear or damage.
  2. If leaks or inconsistent flushing occur, these components may need replacement. Refer to Sloan's official service guides for detailed replacement procedures.

6.3. Control Stop Adjustment

  1. The control stop plug allows for adjustment of water flow. If the flush volume is too low or too high, use a screwdriver to adjust the control stop.
  2. Turn clockwise to decrease flow, counter-clockwise to increase flow. Adjust incrementally until desired flush is achieved.

7. Solució De Problemes

This section addresses common issues you might encounter with your flushometer.

ProblemaCausa possibleSolució
Flushometer does not flushWater supply turned off; Clogged internal components; Handle mechanism issue.Check water supply valve; Inspect and clean diaphragm/bypass; Check handle assembly for obstructions.
Continuous flushing or slow closingWorn or damaged diaphragm; Debris in bypass hole; Improperly seated components.Replace diaphragm; Clean bypass hole; Reassemble components correctly.
Insufficient flush volumeControl stop not fully open; Low water pressure; Partially clogged inlet.Adjust control stop to increase flow; Check building water pressure; Inspect and clean inlet screen.
Fuites de connexionsLoose connections; Damaged gaskets/seals; Improperly applied sealant.Tighten connections; Replace worn gaskets/seals; Reapply pipe sealant correctly.

If troubleshooting steps do not resolve the issue, contact Sloan customer support or a qualified plumber.

8. Especificacions

CaracterísticaDetall
Número de model3082675
Volum de ras1.0 GPF (galons per descàrrega)
AcabarCrom polit
MaterialBrass (High copper, low zinc castings)
Connexió de l'aparellTop Spud
Tipus de mànecManual, Non-Hold-Open, ADA Compliant Metal Oscillating
Trencador de buitInclòs
Angle Stop3/4" I.P.S. Screwdriver Bak-Chek
Dimensions (aprox.)1 x 2 x 3 polzades (dimensions del producte)
Pes de l'article6 lliures
CertificacióADA

9. Garantia i assistència

9.1. Informació de la garantia

The Sloan Regal 186 Exposed Manual Urinal Flushometer (Model 3082675) comes with a Garantia limitada d'3 any. This warranty covers defects in materials and workmanship under normal use and service. For full details regarding warranty coverage, limitations, and claims, please refer to the official Sloan warranty documentation or contact Sloan customer support.

9.2. Atenció al client

For technical assistance, replacement parts, or warranty inquiries, please contact Sloan customer support. Visit the official Sloan weblloc web per obtenir informació de contacte i recursos addicionals.

Note: Always provide your product model number (3082675) when contacting support for faster service.