1. Introducció
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Eltako ESR12NP-230V+UC Impulse Switch. Please read these instructions carefully before use and retain them for future reference. The Eltako ESR12NP-230V+UC is an electronic impulse switch designed for controlling lighting circuits, featuring a return delay, continuous light function, and a warning signal before switch-off.
2. Instruccions de seguretat
Avís: Electrical installation should only be performed by a qualified electrician. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect power at the main circuit breaker before performing any installation or maintenance.
- Assegureu-vos que el subministrament voltage matches the specifications of the device (230V).
- No feu servir el dispositiu si està danyat.
- Protegiu el dispositiu de la humitat i les temperatures extremes.
- Observeu tots els codis i regulacions elèctriques locals i nacionals.
3. Producte acabatview
The Eltako ESR12NP-230V+UC is a sophisticated impulse switch utilizing hybrid technology, combining the benefits of wear-free electronic control with a high-performance special relay. It is designed for efficient and quiet operation in various lighting control applications, particularly in stairwells or common areas where timed lighting is required.

Figura 1: Davant view of the Eltako ESR12NP-230V+UC impulse switch, showing the control knob and terminals. This device is designed for DIN rail mounting.
Les característiques clau inclouen:
- Electronic control with return delay.
- Warning before switch-off and continuous light function.
- Low standby power consumption (only 0.5 W).
- Zero-crossing switching for contact and lamp protection, extending the lifespan of energy-saving lamps.
- Galvanically isolated universal control voltage.
- Very low operating noise.
- Adjustable return delay time from 2 to 120 minutes.
- Indicador LED de control.
4. Configuració i instal·lació
The ESR12NP-230V+UC is designed for DIN rail mounting within an electrical distribution board. Ensure adequate space and ventilation according to local regulations.
4.1 Muntatge
- The device has a width of 1 module unit and a mounting depth of 58 mm.
- Snap the impulse switch onto a standard 35mm DIN rail in your electrical panel.
- Assegureu-vos que estigui ben subjectat.
4.2 Cablejat
Refer to the wiring diagram provided with the product packaging for specific connection details. General wiring principles are as follows:
- Connect the main power supply (230V) to the designated input terminals.
- Connect the lighting circuit (load) to the output terminals. The device features one normally open contact.
- Connect control buttons (pushbuttons) to the control input terminals. The control voltage és 230V.
- The device supports a flash lamp current of up to 150 mA at 230V control input, independent of the ignition voltage.
- Ensure all connections are tight and correctly insulated.
5. Instruccions de funcionament
5.1 Basic Operation (Impulse Function)
- Press a connected pushbutton briefly to turn on the light.
- The light will remain on for the set delay time.
- To turn off the light prematurely, press the pushbutton again briefly.
5.2 Setting the Return Delay Time
The return delay time can be precisely adjusted from 2 to 120 minutes using the rotary knob on the front of the device. Rotate the knob to select the desired duration. The scale is marked in minutes.
5.3 Continuous Light Function
To activate continuous light, press and hold the pushbutton for approximately 3 seconds. The light will remain on until manually switched off or until a maximum duration (e.g., 3 hours, depending on specific model configuration) is reached.
5.4 Warning Before Switch-Off
Before the light automatically switches off at the end of the set delay or continuous light period, the control LED will flash (e.g., after 15 minutes with a locked button, or as a warning for the impending switch-off). This provides a visual alert to users.
5.5 Power Failure Behavior
In the event of a power supply failure, the device is designed to default to the "off" state for safety.
6. Manteniment
The Eltako ESR12NP-230V+UC impulse switch is designed for long-term, maintenance-free operation. However, periodic checks are recommended:
- Neteja: Assegureu-vos que el dispositiu estigui lliure de pols i brutícia. Feu servir un drap sec i suau per netejar-lo. No utilitzeu netejadors líquids.
- Inspecció: Periodically inspect the wiring connections for tightness and signs of wear or damage.
- Prova de funcionalitat: Occasionally test the impulse and delay functions to ensure proper operation.
For any repairs, contact qualified personnel or Eltako customer support.
7. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| La llum no s’encén. | No power supply; faulty wiring; defective pushbutton; device malfunction. | Check main circuit breaker. Verify all wiring connections. Test pushbutton. If issues persist, consult a qualified electrician. |
| La llum no s'apaga. | Delay time set too long; continuous light function active; faulty pushbutton; device malfunction. | Check delay time setting. Briefly press pushbutton to cancel continuous light. Test pushbutton. If issues persist, consult a qualified electrician. |
| Control LED not working. | Sense alimentació; mal funcionament del dispositiu. | Check power supply. If power is present and device functions otherwise, the LED may be faulty. |
| El dispositiu fa un soroll estrany. | Problema amb el component intern. | Disconnect power immediately and contact a qualified electrician or Eltako support. |
8. Especificacions tècniques
| Característica | Especificació |
|---|---|
| Marca | Eltako |
| Número de model | 2000386 |
| Mode de funcionament | ON-OFF |
| Corrent nominal | 230 Amperes (Note: This likely refers to the maximum switching current, not continuous operating current of the device itself) |
| Vol. Operatiutage | 230 Volts |
| Tipus de contacte | Normalment obert (Based on feature bullets, contradicting 'Normally Closed' in specifications list) |
| Tipus de connexió | DIN |
| Tipus de canvi | Rotativa |
| Tipus de terminal | Button (Pushbutton) |
| Material | Plàstic |
| Tipus de circuit | 2-posicions |
| Tipus de muntatge | Muntatge sobre carril DIN |
| Tipus d'actuador | Pulsador |
| Nombre de llocs | 1 |
| Tipus de controlador | Anella |
| Mètode de control | Toca |
| Protocol de comunicació | DIN |
| Wattage | 3680 W |
| Color | Blau |
| Nombre d'unitats | 1 |
| Nombre d'elements | 1 |
| Material de contacte | Acer inoxidable |
| Classificació de protecció internacional | IP54 |
| Compliment | CE |
| Disponibilitat de recanvis a la UE | 1 any |
| GTIN | 04010312107928 |
| Fabricant | Eltako |
| ASIN | B000UWEXH4 |
Nota: Les especificacions estan subjectes a canvis sense previ avís. Consulteu sempre l'etiqueta del producte per obtenir la informació més precisa.
9. Garantia i Suport
9.1 Informació de la garantia
Eltako products are covered by a standard manufacturer's warranty against defects in materials and workmanship. The specific duration and terms of the warranty may vary by region. Please retain your proof of purchase for warranty claims. For detailed warranty information, refer to the documentation included with your product or visit the official Eltako weblloc.
9.2 Atenció al client
If you encounter any issues or have questions regarding the installation, operation, or maintenance of your Eltako ESR12NP-230V+UC Impulse Switch, please contact your retailer or the official Eltako customer support. Contact details can typically be found on the manufacturer's weblloc o embalatge del producte.