1. Introducció

The MANHATTAN Digital Power Supply Tester, Model 101530, is a diagnostic tool designed to quickly and accurately test the functionality of ATX computer power supply units (PSUs). It supports 20-pin and 24-pin ATX connectors, as well as various peripheral connectors, providing real-time voltage readings and indicating potential faults with audible alarms. This manual provides essential information for the safe and effective use of your power supply tester.

2. Informació de seguretat

  • Always ensure the power supply unit is disconnected from the main power outlet before connecting or disconnecting the tester.
  • Do not attempt to open or modify the tester. There are no user-serviceable parts inside.
  • Avoid exposing the tester to moisture, extreme temperatures, or direct sunlight.
  • Handle the connectors carefully to prevent bending pins or damaging the ports.
  • Use the tester only for its intended purpose: testing computer power supply units.

3. Contingut del paquet

Verifiqueu que el vostre paquet conté el següent article:

  • MANHATTAN Digital Power Supply Tester (Model 101530)
MANHATTAN Digital Power Supply Tester, front view

Imatge: Frontal view of the MANHATTAN Digital Power Supply Tester, showing the LCD screen and various connectors.

4. Característiques del producte

The MANHATTAN Digital Power Supply Tester offers the following features:

  • Compatibilitat: Supports ATX 20-pin and 24-pin power supply units.
  • Connector Support: Includes ports for 4-pin, 6-pin, and 8-pin CPU connectors, 4-pin FDD (Floppy Disk Drive), 4-pin Molex (HDD), and SATA power connectors.
  • Pantalla LCD digital: Proporciona vol en temps realtage readings for +12V, -12V, +5V, +3.3V, and +5VSB (Standby Voltagi).
  • PG Value Display: Shows the Power Good (PG) signal value in milliseconds.
  • Voltage Presence LEDs: Indicators for +12V, +5V, and +3.3V.
  • Alarmes sonores: Alerts the user to detected voltage faults or out-of-specification PG values.
  • Construcció duradora: Features an aluminum casing per a una major durabilitat.

5. Configuració i connexió

Follow these steps to connect the power supply tester:

  1. Ensure PSU is Off: Before connecting the tester, ensure the power supply unit is completely powered off and disconnected from the AC mains power outlet.
  2. Connect Main ATX Connector: Plug the 20-pin or 24-pin ATX connector from the power supply into the corresponding port on the tester. Ensure it is firmly seated.
  3. Connect Other Connectors (Optional): Connect any other power supply connectors you wish to test (e.g., 4-pin Molex, SATA, 4-pin/6-pin/8-pin CPU, FDD) into their respective ports on the tester. It is recommended to connect at least one peripheral connector (like a Molex or SATA) in addition to the main ATX connector for a comprehensive test.
  4. Engegar la font d'alimentació: Once all desired connectors are securely attached to the tester, connect the power supply unit to the AC mains power outlet and switch it on.
MANHATTAN Digital Power Supply Tester with display showing voltage lectures

Image: The MANHATTAN Digital Power Supply Tester with its LCD display active, showing various voltage readings and the Power Good (PG) value.

6. Instruccions de funcionament

Upon powering on the PSU, the tester's LCD display will illuminate and show the voltage readings for the connected lines. The voltage presence LEDs will also light up.

6.1. Lectura de la pantalla

  • Voltage Lectures: The display will show the measured voltages for +12V, -12V, +5V, +3.3V, and +5VSB.
  • Power Good (PG) Value: The PG value, typically displayed in milliseconds (ms), indicates the time it takes for the power supply to stabilize its output voltages after being turned on. A normal PG value is usually between 100ms and 500ms.
  • Indicadors LED: The LEDs for +12V, +5V, and +3.3V will light up if these voltagsón presents.

6.2. Interpretació de resultats

The tester will emit an audible alarm and flash the corresponding voltage reading if any voltage is outside its acceptable tolerance range or if the PG value is out of specification (e.g., too low or too high).

Table 1: Standard ATX Voltage Toleràncies
Voltage FerrocarrilVolum nominaltageRang acceptable
+12V+12.00V+11.40V a +12.60V
-12V-12.00V-10.80V a -13.20V
+5V+5.00V+4.75V a +5.25V
+3.3V+3.30V+3.135V a +3.465V
+5VSB (Standby)+5.00V+4.75V a +5.25V

If any reading falls outside these ranges, or if the PG value is abnormal, the power supply may be faulty and should be replaced.

7. Manteniment

  • Neteja: Use a soft, dry cloth to clean the exterior of the tester. Do not use liquid cleaners or solvents.
  • Emmagatzematge: Store the tester in a cool, dry place, away from direct sunlight and extreme temperatures. Protect the exposed pins of the FDD connector to prevent bending.
  • No hi ha peces reparables per l'usuari: The device does not require internal maintenance. Any attempt to open the casing anul·larà la garantia.

8. Solució De Problemes

If you encounter issues with your MANHATTAN Digital Power Supply Tester, refer to the following common problems and solutions:

  • Sense pantalla/Sense alimentació:
    • Ensure the main 20-pin or 24-pin ATX connector is fully seated in the tester.
    • Verify that the power supply unit is connected to an active AC outlet and is switched on.
    • Test the power supply with a known working power supply unit if available, or test the outlet with another device.
  • Audible Alarm Sounds:
    • An alarm indicates a voltage reading is outside the acceptable tolerance range or the PG value is incorrect. Refer to Table 1 for acceptable voltagrangs e.
    • Note which voltage rail is flashing on the display; this indicates the problematic line.
    • If an alarm persists, the power supply unit is likely faulty and requires replacement.
  • Lectures inconsistents:
    • Ensure all connectors are clean and free of debris.
    • Reconnect all cables firmly. Loose connections can lead to inaccurate readings.
    • If possible, test the power supply unit in a different environment to rule out external electrical interference.

9. Especificacions

CaracterísticaDetall
Número de model101530
Connectors compatiblesATX 20-pin, ATX 24-pin, 4-pin CPU, 6-pin CPU, 8-pin CPU, 4-pin FDD, 4-pin Molex, SATA
Voltage Interval de prova+12V, -12V, +5V, +3.3V, +5VSB
PG Value Range100ms - 500ms (typical)
MostraLCD
IndicadorsLEDs for +12V, +5V, +3.3V; Audible alarm
Dimensions del producte7.6 x 6.1 x 0.8 polzades (19.3 x 15.5 x 2.0 cm)
Pes de l'article4 unces (113 grams)
FabricantProductes Manhattan

10. Garantia i Suport

MANHATTAN products are designed to provide reliable performance. This product may be covered by a Garantia de per vida, as indicated on some product packaging. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official MANHATTAN weblloc.

For technical support, product information, or warranty claims, please contact MANHATTAN customer service through their official website or the contact information provided with your product. Please have your model number (101530) and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.