Testboy Testavit Schuki 2K

Testboy Testavit Schuki 2K Socket Tester with RCD Test

Model: Testavit Schuki 2K | Brand: Testboy

1. Introducció i finalview

The Testavit Schuki 2K is a compact and reliable socket tester designed for quick and safe verification of 230V electrical outlets. It integrates an RCD (Residual Current Device) test function with adjustable nominal residual current settings, making it an essential tool for electricians and DIY enthusiasts. This manual provides detailed instructions for the proper use and maintenance of your device.

Testboy Testavit Schuki 2K Socket Tester

Image 1.1: The Testboy Testavit Schuki 2K socket tester, showing its compact design and integrated plug.

2. Informació de seguretat

Always prioritize safety when working with electrical systems. This device is designed for testing live circuits; therefore, extreme caution must be exercised. Failure to follow safety guidelines can result in electric shock, injury, or damage to property.

  • Llegiu aquest manual d’instruccions a fons abans d’utilitzar-lo.
  • Ensure the device is in good condition. Do not use if it appears damaged.
  • This device is compliant with IEC 61010-1 standards.
  • Always wear appropriate personal protective equipment (PPE) when performing electrical tests.
  • Do not attempt to open or repair the device. Refer to qualified personnel for service.
  • Comproveu el voltage of the circuit before testing to ensure it matches the device's specifications (230V AC).

3. Característiques del producte

The Testavit Schuki 2K offers several key features for comprehensive socket testing:

  • Advanced System: Equipped with a cable and earthed plug, allowing easy checking of sockets in 230V systems, including those in hard-to-reach locations.
  • RCD Test Function: Perform RCD tests with an adjustable nominal residual current. Selectable settings include 10 mA, 30 mA, 100 mA, 300 mA, or 500 mA.
  • Qualitat i seguretat: All Testboy devices undergo stringent quality and safety tests in the company's production facility.
  • Disseny compacte: Its small and ergonomic size ensures comfortable handling and easy storage in any toolbox.
  • Funcionament sense bateries: The device is powered directly by the circuit being tested, eliminating the need for batteries.

4. Components i controls

Familiarize yourself with the different parts and controls of the Testavit Schuki 2K:

  • Indicadors LED: Multiple LEDs display the status of Phase (L1/PH), Earth (PE/SL), and Neutral (N/MP) connections.
  • RCD Current Selector Dial (S1): Used to select the desired nominal residual current for the RCD test (10mA, 30mA, 100mA, 300mA, 500mA, OFF).
  • RCD Test Button (T): Initiates the RCD test.
  • Test Button (TEST): Used for specific wiring tests.
  • Earthed Plug: Connects the device to the socket under test.
Close-up of Testboy Testavit Schuki 2K controls

Imatge 4.1: Primer pla view of the LED indicators, RCD current selector dial, and test buttons on the Testavit Schuki 2K.

5. Configuració

Setting up the Testavit Schuki 2K is straightforward:

  1. Ensure the socket to be tested is live and operating at 230V AC.
  2. Visually inspect the Testavit Schuki 2K for any signs of damage.
  3. Plug the device's earthed plug firmly into the socket you wish to test.
  4. The device will immediately begin to indicate the wiring status via its LED display.
Testboy Testavit Schuki 2K plugged into a wall socket

Image 5.1: The Testavit Schuki 2K plugged into a standard wall socket, ready for testing.

6. Instruccions de funcionament

6.1. Socket Wiring Test

Once plugged into a 230V socket, the device's LEDs will illuminate to indicate the wiring status. Refer to the legend on the device for specific interpretations. Common indications include:

  • Cablejat correcte: All LEDs illuminate in a specific pattern (refer to device markings).
  • Missing Earth: A specific LED pattern indicates the absence of an earth connection.
  • Reversed Phase/Neutral: Another pattern indicates incorrect phase and neutral connections.
  • Missing Phase or Neutral: Specific LEDs will not illuminate.

Always consult the detailed legend on the device itself for precise interpretation of the LED patterns for various fault conditions.

6.2. RCD (Residual Current Device) Test

The RCD test function verifies the proper operation of the residual current device protecting the circuit.

  1. Plug the Testavit Schuki 2K into the socket.
  2. Rotate the RCD Current Selector Dial (S1) to the desired nominal residual current setting (e.g., 30 mA).
  3. Press and hold the red RCD Test Button (T).
  4. Observe the RCD (circuit breaker) in your electrical panel. A functional RCD should trip (switch off) within a short period (typically less than 200ms).
  5. If the RCD trips, it indicates that the RCD is functioning correctly at the selected current. Reset the RCD at your electrical panel.
  6. If the RCD does not trip, it indicates a potential fault with the RCD or the wiring. Do not use the circuit and consult a qualified electrician.
  7. After testing, return the RCD Current Selector Dial (S1) to the "OFF" position.
Close-up of Testboy Testavit Schuki 2K RCD test section

Imatge 6.1: Detallada view of the RCD current selector dial and the red RCD test button.

7. Manteniment

The Testavit Schuki 2K requires minimal maintenance to ensure its longevity and accurate operation.

  • Neteja: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.
  • Emmagatzematge: Store the device in a dry, cool place, away from direct sunlight and extreme temperatures. Keep it in its original packaging or a protective case when not in use.
  • Inspecció: Periodically inspect the cable and plug for any signs of wear, cuts, or damage. If any damage is found, discontinue use immediately.
  • There are no user-serviceable parts inside the Testavit Schuki 2K. Any repairs should only be performed by authorized service personnel.

8. Solució De Problemes

If you encounter issues with your Testavit Schuki 2K, consider the following:

ProblemaCausa possibleSolució
No LEDs illuminate when plugged in.No power to the socket; device is faulty.Check the circuit breaker for the socket. Test the socket with another known working appliance. If still no lights, the device may be faulty.
Incorrect wiring indicated (e.g., missing earth).Actual wiring fault in the socket.Do not use the socket. Consult a qualified electrician to inspect and repair the wiring.
RCD does not trip during test.Faulty RCD; incorrect RCD current setting; no earth connection.Ensure the RCD current selector is not on "OFF". Verify socket wiring (especially earth). If the RCD still doesn't trip, it may be faulty and requires inspection by a qualified electrician.
Device appears damaged.Dany físic.Discontinue use immediately. Do not attempt to repair. Contact Testboy customer support.

9. Especificacions

EspecificacióValor
MarcaNoi de prova
Número de modelTestavit Schuki 2K
Font d'alimentacióElectrical power with cable (no batteries required)
EstilCompacte
ColorGris
Dimensions de l'article (L x A x A)15.5 x 9 x 5.5 centímetres
Vol operatiu mínimtage230 Volts AC (VAC)
Volum de funcionament màximtage230 Volts
Norma de complimentIEC 61010-1
Tipus de mesuraOhmmeter or Multimeter (for internal functions)
Disponibilitat de recanvis a la UE1 any
País d'origenXina

10. Garantia i Suport

Testboy products are manufactured to high-quality standards. This product comes with a stated EU spare parts availability of 1 year. For warranty claims, technical support, or service inquiries, please contact Testboy customer service through their official channels. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.