VOLTCRAFT K204D
VOLTCRAFT K204-200 Temperature Measurement Device User Manual
Model: K204D
Introducció
The VOLTCRAFT K204-200 is a high-precision temperature measurement device designed for professional applications. It features a wide measurement range from -200 °C to +1370 °C and includes an RS-232 interface for data transfer to a computer. With an integrated memory capacity of 16,000 measurement values, it is suitable for long-term process monitoring and data logging.
Informació de seguretat
Si us plau, llegiu i comprengui totes les instruccions de seguretat abans de fer servir el dispositiu. Si no segueix aquestes instruccions, pot patir lesions o danys al dispositiu.
- Always use the device within its specified temperature range.
- No exposeu el dispositiu a temperatures extremes, humitat o llum solar directa.
- Ensure proper battery installation and replacement.
- Eviteu deixar caure el dispositiu o sotmetre-lo a forts impactes.
- No intenteu desmuntar ni modificar el dispositiu. Encarregueu tot el manteniment a personal qualificat.
- Mantingueu el dispositiu lluny dels nens.
Contingut del paquet
Carefully unpack the device and check for the following components:
- VOLTCRAFT K204-200 Temperature Measurement Device (1 unit)
- K-type Thermocouple Probes (quantity may vary based on kit)
- RS-232 Data Cable
- Software CD (for data transfer and analysis)
- Manual d'usuari

Image: The VOLTCRAFT K204-200 kit, including the device, probes, and accessories, neatly packed in its carrying case.
Dispositiu acabatview
Familiarize yourself with the main components and controls of your VOLTCRAFT K204-200.

Imatge: Frontal view of the VOLTCRAFT K204-200, highlighting the display and button layout.
- Pantalla LCD: Shows temperature readings, units, and various indicators.
- Botó d'encesa: Encén/apaga el dispositiu.
- Botó REL: Relative measurement function.
- Botó HOLD: Congela la lectura actual a la pantalla.
- AVG/MAX/MIN Button: Cycles through average, maximum, and minimum recorded temperatures.
- Botó TIMER: Activa la funció de temporitzador.
- Botó °C/°F: Toggles between Celsius and Fahrenheit units.

Imatge: Lateral view of the VOLTCRAFT K204-200, showing the DC 9V power input and RS-232 data port.
- Thermocouple Inputs (T1, T2, T3, T4): Ports for connecting K-type thermocouple probes.
- Entrada DC 9V: Per a font d'alimentació externa.
- Port RS-232: Per connectar-se a un ordinador per transferir dades.
Configuració
- Instal·lació de la bateria:
Obriu la tapa del compartiment de la bateria a la part posterior del dispositiu. Introduïu una bateria de 9 V, assegurant-vos de la polaritat correcta. Tanqueu la tapa de manera segura.

Imatge: Part posterior view of the device with the battery compartment open, illustrating battery insertion.
- Connecting Thermocouple Probes:
Connect the K-type thermocouple probes to the designated input ports (T1, T2, T3, T4) on the top of the device. Ensure a firm connection.
- Engegada inicial:
Press the Power button to turn on the device. The display will illuminate and show the current temperature readings from the connected probes.
- Software Installation (for Data Logging):
Insert the provided software CD into your computer's CD/DVD drive and follow the on-screen instructions to install the data logging software. This software is required to utilize the RS-232 interface and transfer recorded data.
Instruccions de funcionament
- Mesura bàsica:
After powering on, the device will automatically display the temperature from the connected probes. Ensure probes are properly placed at the measurement point.
- Canvi d'unitats de temperatura (°C/°F):
Premeu el botó ° C / ° F button to toggle between Celsius and Fahrenheit temperature scales.
- Funció de retenció de dades:
Premeu el botó MANTENIM button to freeze the current temperature reading on the display. Press it again to release and resume live readings.
- Maximum, Minimum, and Average Readings:
Premeu el botó AVG/MAX/MIN button repeatedly to cycle through the average, maximum, and minimum temperature values recorded since the device was powered on or the function was reset.
- Mesura relativa (REL):
Premeu el botó REL button to set the current reading as a reference point. Subsequent readings will be displayed as a deviation from this reference.
- Funció de temporitzador:
Premeu el botó TEMPORIZADOR button to activate the built-in timer. Refer to the software manual for detailed instructions on configuring and using the timer for specific measurement intervals.
- Data Logging (16,000 Values):
The device can store up to 16,000 measurement values. To initiate data logging and transfer data to your computer, connect the device via the RS-232 port and use the installed software. Consult the software's user manual for detailed instructions on setting up logging parameters and exporting data.
Manteniment
- Neteja:
Netegeu l'exterior del dispositiu amb un drap suau iamp drap. No utilitzeu productes de neteja abrasius ni dissolvents. Assegureu-vos que el dispositiu estigui sec abans de guardar-lo o utilitzar-lo el proper cop.
- Substitució de la bateria:
When the low battery indicator appears on the display, replace the 9V battery as described in the Setup section. Dispose of old batteries responsibly.
- Emmagatzematge:
When not in use for extended periods, remove the battery to prevent leakage. Store the device in its original carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El dispositiu no s'encén. | Bateria morta o instal·lada incorrectament. | Comproveu la polaritat de la pila o substituïu-la per una pila nova de 9 V. |
| Lectures de temperatura inexactes. | Probe not properly connected or damaged; incorrect probe type. | Ensure probes are securely connected. Verify that K-type probes are used. Replace damaged probes. |
| Data transfer to PC fails. | RS-232 cable not connected; software not installed or configured correctly. | Check cable connection. Reinstall software and refer to its manual for setup. |
| Display shows "OL" or "--- ". | Temperature is out of range or probe is open circuit. | Ensure temperature is within -200 °C to +1370 °C. Check probe for damage. |
Especificacions
| Característica | Detall |
|---|---|
| Número de model | K204D |
| Interval de mesura | -200 ° C a +1370 ° C (-328 ° F a +2498 ° F) |
| Tipus de sonda | Termopar tipus K |
| Canals | 4 |
| Data Logger Capacity | 16,000 measurement values |
| Connectivitat | RS-232 |
| Tipus de visualització | Digital |
| Font d'alimentació | Bateria de 9 V |
| Material exterior | Plàstic |
| Dimensions del producte (L x A x A) | 18.4 x 6.4 x 3 cm (7.24 x 2.52 x 1.18 polzades) |
| Pes | 180 grams (0.4 lliures) |
| País d'origen | França |
Garantia i Suport
VOLTCRAFT provides a 1-year availability for spare parts for the K204-200 device. For technical support, warranty claims, or service inquiries, please contact your local VOLTCRAFT distributor or visit the official VOLTCRAFT weblloc per obtenir informació de contacte.
Si us plau, conserveu el comprovant de compra per a qualsevol reclamació de garantia.