Eaton OS310U-W-K

Eaton OS310U-W-K Motion Sensor Switch User Manual

Model: OS310U-W-K

1. Introducció

The Eaton OS310U-W-K is a motion-activated occupancy sensor wall switch designed to automatically control lighting based on room occupancy. This device enhances energy efficiency by turning lights on when a person enters a room and off after a selectable time delay once the room is vacated. It is compatible with a wide range of lighting loads, including incandescent, magnetic low voltage (MLV), electronic low voltage (ELV), fluorescent, compact fluorescent (CFL), and LED lights, as well as motors up to 1/6 HP.

This manual provides detailed instructions for the safe installation, operation, and maintenance of your Eaton OS310U-W-K motion sensor switch.

2. Informació de seguretat

ADVERTIMENT: To avoid fire, shock, or death; turn off power at the circuit breaker or fuse box and test that the power is off before wiring. All wiring must be performed in accordance with national and local electrical codes.

  • Desconnecteu sempre l'alimentació a l'interruptor automàtic abans de la instal·lació o el manteniment.
  • A neutral wire is required for the installation of this device. Verify your switch box wiring includes a neutral wire before proceeding.
  • Aquest dispositiu només està dissenyat per a ús interior.
  • Do not use with dimmable fluorescent fixtures unless specifically rated for occupancy sensor control.
  • Si teniu dubtes sobre alguna part del procés d'instal·lació, consulteu un electricista qualificat.

3. Característiques del producte

  • Funcionament automàtic: Lights turn on automatically upon motion detection and off after a set delay.
  • Compatibilitat versàtil: Works with incandescent, MLV, ELV, fluorescent, CFL, and LED lighting loads, as well as 1/6 HP motors.
  • Àmplia cobertura: Ofereix un camp de 180 graus de view and up to 1000 square feet of major motion coverage.
  • Flexible Wiring: Supports both single-pole and 3-way wiring configurations.
  • Retard de temps ajustable: Selectable time delays of 5 seconds (test mode), 5 minutes (factory default), 15 minutes, and 30 minutes.
  • Ambient Light Override: Prevents lights from turning on if sufficient natural light is present.
  • Integrated Nightlight: Selectable on/off LED nightlight with press-and-hold dimming function.
  • Walk-in-Delay Feature: Shortens the time delay when motion is detected briefly, saving energy.
  • Modes de funcionament: Toggle between auto-on/auto-off or manual-on/auto-off modes.
  • Funció de bypass: Allows the sensor to operate as a traditional manual on/off switch.
  • Indicador LED: Green LED indicates load status, acts as a locator light in the dark, and blinks upon motion detection.
  • Decorator Style: Includes a mid-size decorator wall plate.

4. Configuració i instal·lació

The Eaton OS310U-W-K is designed to fit into a standard wall box and replaces a traditional light or fan switch. Installation requires a neutral wire. If your existing switch box does not have a neutral wire, consult an electrician.

4.1 Requisits de cablejat

  • Cables necessaris: Ground, Hot (Line), Load, and Neutral.
  • 3-Way Configuration: For 3-way operation, an additional traveler wire is needed. Note that 3-way wiring for this sensor switch differs from standard 3-way switches; the wiring is effectively in parallel. Refer to the detailed wiring diagram provided with your product packaging for specific instructions.
  • The device comes with 6-inch pre-stripped #14 AWG wire leads for connection.

4.2 Passos d'instal·lació

  1. Apagueu l'alimentació: A l'interruptor automàtic o a la caixa de fusibles, desconnecteu l'alimentació de la ubicació de l'interruptor. Verifiqueu que l'alimentació estigui apagada utilitzant un voltimetre.tage provador.
  2. Treure l'interruptor antic: Carefully remove the existing wall plate and switch from the wall box. Disconnect the wires from the old switch, noting their connections.
  3. Identificar els cables: Identify the Line (Hot), Load, Neutral, and Ground wires in the wall box. The neutral wire is typically white.
  4. Connecta el nou interruptor: Connect the wires from the Eaton OS310U-W-K switch to the corresponding wires in the wall box using wire nuts. Ensure all connections are secure.
    • Connect the green wire from the sensor to the bare copper or green ground wire in the wall box.
    • Connect the black wire from the sensor to the Line (Hot) wire.
    • Connect the red wire from the sensor to the Load wire (to the light fixture).
    • Connect the white wire from the sensor to the Neutral wire.
    • For 3-way installations, refer to the specific wiring diagram provided with the product.
  5. Interruptor de muntatge: Carefully fold the wires into the wall box and secure the switch to the wall box with the provided screws.
  6. Instal·leu la placa de paret: Attach the decorator mid-size wall plate.
  7. Restaura l'alimentació: Torneu a encendre l'alimentació al disjuntor.
Eaton OS310U-W-K Motion Sensor Switch, White

Image of the Eaton OS310U-W-K motion sensor switch in white, showing its decorator style and push-button interface.

5. Instruccions de funcionament

5.1 Automatic Operation (Occupancy Mode)

In this mode, the lights will automatically turn on when motion is detected and turn off after the set time delay once the room is vacant. This is the default operating mode.

5.2 Manual-On / Auto-Off Mode (Vacancy Mode)

To switch to manual-on/auto-off mode, press and hold the main switch button for a few seconds until the indicator light changes. In this mode, you must manually turn on the lights by pressing the switch button. The lights will then automatically turn off after the set time delay when no motion is detected.

5.3 Bypass Feature (Traditional Switch Mode)

The bypass feature allows the sensor to function as a traditional manual on/manual off switch, ignoring motion detection. Consult the product's detailed instructions for how to activate and deactivate this mode, typically involving a specific press-and-hold sequence.

5.4 Funció de llum nocturna

The integrated LED nightlight can be turned on or off and its brightness adjusted. Press and hold the nightlight button (if separate) or a specific section of the main button to dim the nightlight. The nightlight provides a locator light in the dark.

5.5 indicador LED

A green LED on the switch indicates the load status (lights on/off). It also serves as a locator light in dark conditions and blinks to signal motion detection.

6. Paràmetres de configuració

The Eaton OS310U-W-K offers several adjustable settings to customize its operation. These settings are typically accessed by removing the wall plate and adjusting small dials or switches on the device itself.

6.1 Time Delay Adjustment

The time delay determines how long the lights remain on after the last detected motion. Available settings include:

  • 5 seconds (Test Mode)
  • 5 minutes (Factory Default)
  • 15 minuts
  • 30 minuts

6.2 Ambient Light Override

This setting allows you to prevent the lights from turning on automatically if there is sufficient natural light in the room. This feature helps conserve energy by ensuring lights are only activated when truly needed.

6.3 Walk-in-Delay

The walk-in-delay feature intelligently shortens the time delay if motion is detected only briefly, further optimizing energy savings.

7. Manteniment

The Eaton OS310U-W-K motion sensor switch requires minimal maintenance.

  • Neteja: To clean the device, gently wipe the surface with a soft, damp drap. No utilitzeu netejadors abrasius, dissolvents ni productes químics agressius, ja que poden danyar l'acabat o els components interns.
  • Inspecció: Periodically inspect the switch and wall plate for any signs of damage or loose connections. If any issues are found, turn off power at the circuit breaker and address them or consult a qualified electrician.

8. Solució De Problemes

If you encounter issues with your Eaton OS310U-W-K motion sensor switch, refer to the following common problems and solutions:

Problema Causa possible Solució
Els llums no s'encenen amb moviment.
  • L'alimentació està apagada.
  • Cablejat incorrecte.
  • Ambient light override is active and room is too bright.
  • Sensor lens is obstructed.
  • Switch is in manual-on mode.
  • Comproveu l'interruptor.
  • Verify wiring connections (Line, Load, Neutral, Ground).
  • Adjust ambient light setting or test in darker conditions.
  • Elimineu qualsevol obstrucció de la lent del sensor.
  • Switch to auto-on/auto-off mode.
Els llums no s'apaguen.
  • Moviment continu detectat.
  • El retard de temps s'ha configurat massa llarg.
  • Faulty wiring or device.
  • Ensure no constant motion sources are within sensor range.
  • Adjust time delay to a shorter setting.
  • Recheck wiring. If problem persists, contact support.
Switch is difficult to fit into wall box.
  • Bulky wiring or small wall box.
  • Carefully arrange wires to maximize space. Ensure all connections are secure and compact.
Nightlight not working or dimming.
  • Nightlight feature is off.
  • Funcionament incorrecte.
  • Activate the nightlight feature.
  • Use the press-and-hold function to adjust brightness.

9. Especificacions

Característica Especificació
Número de model OS310U-W-K
Vol. Operatiutage 120 Vca, 60 Hz
Wat màxtage 1000 W
Valoració actual 8.3 A
Càrregues compatibles Incandescent, Magnetic Low-Voltage, Electronic Low-Voltage, Fluorescent, Compact Fluorescent (CFL), LED, Motors up to 1/6 HP
Camp de View 180 graus
Àrea de cobertura Up to 1000 sq ft (major motion)
Configuració de retard de temps 5 seconds (test), 5 minutes, 15 minutes, 30 minutes
Temperatura de funcionament De 32 °F a 104 °F (de 0 °C a 40 °C)
Material Polycarbonate (housing), Copper (contact)
Dimensions (L x A x A) 34 x 26.4 x 29.6 cm (approximate, as per item dimensions)
Certificacions cULus listed, Nom certified, California Title 24 Compliant
Cablejat Single-pole or 3-way, Neutral required, 6-inch pre-stripped #14 AWG wire leads

10. Garantia i Suport

10.1 Garantia del fabricant

Eaton products are backed by a manufacturer's warranty. Please refer to the warranty information included with your product packaging or visit the official Eaton weblloc web per obtenir més informació sobre els termes, les condicions i la durada de la garantia.

10.2 Suport tècnic

For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact Eaton customer support. Contact information can typically be found on the product packaging, the Eaton website, or by searching for 'Eaton Electrical Support'.

When contacting support, please have your product model number (OS310U-W-K) and purchase date available.

© 2023 Eaton Corporation. All rights reserved.

Aquest manual només té finalitats informatives i està subjecte a canvis sense previ avís.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.