1. Informació important de seguretat

Please read and understand all instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage. Retain this manual for future reference.

  • Seguretat elèctrica: Ensure power supply is disconnected before any installation or maintenance. All electrical wiring must be performed by a qualified electrician and comply with local codes and regulations.
  • Seguretat de pressió: This pump operates under pressure. Ensure all connections are secure and leak-free before operation.
  • Seguretat de temperatura: The pump handles fluids up to +130°C (266°F) and short-term up to +140°C (284°F). Exercise caution to avoid burns from hot surfaces or fluids.
  • Instal·lació: This pump is designed for hydronic circulating applications. Do not use for purposes other than its intended use.

2. Producte acabatview

The Wilo Top S 2 x 40 is a wet rotor hydronics circulating pump designed for residential and light commercial applications. It features a robust construction from stainless steel, polypropylene, and metal-impregnated carbon, ensuring durability and efficient performance. This model includes a two-speed motor for manual capacity adjustment.

Wilo Top S 2 x 40 Circulating Pump

Figura 1: Wilo Top S 2 x 40 Wet Rotor Hydronics Circulating Pump. This image displays the main unit of the circulating pump, highlighting its compact design and connection points.

Característiques principals:

  • Wet rotor, seal-less design for quiet and maintenance-free operation.
  • Two pre-selectable speed stages for manual capacity adjustment.
  • Constructed from stainless steel, polypropylene, and metal-impregnated carbon for durability.
  • Cataphoretic coated pump housing for enhanced corrosion resistance.
  • Permitted temperature range: -20°C to +130°C (short-term to +140°C).
  • Pump communication based on simple plug technology for reliable retrofitting.

3. Instal·lació i configuració

Proper installation is crucial for the safe and efficient operation of your Wilo circulating pump. It is highly recommended that installation be performed by a qualified professional.

3.1 Comprovacions prèvies a la instal·lació:

  • Verify that the pump's voltage (115-Volt) matches your electrical supply.
  • Ensure the installation location is suitable, providing adequate space for maintenance and ventilation.
  • Confirm that the system piping is clean and free of debris.

3.2 Mechanical Installation:

  • The pump requires 4 Bolt 2-Inch HV flanges (not included) for connection to the piping system. Ensure these flanges are correctly sized and installed.
  • Install the pump in a horizontal position with the motor shaft horizontal to prevent air pockets and ensure proper lubrication.
  • Use appropriate gaskets and tighten flange bolts evenly to prevent leaks.
  • Support the pump and piping adequately to prevent strain on the connections.

3.3 Connexió elèctrica:

  • All electrical work must comply with national and local electrical codes.
  • Connect the pump to a dedicated, properly fused electrical circuit.
  • Assegureu-vos de posar a terra correctament la bomba.
  • Consulteu el diagrama de cablejat que s'inclou amb la bomba per obtenir detalls específics de connexió.

4. Instruccions de funcionament

Once installed and electrically connected, the Wilo Top S 2 x 40 pump is ready for operation.

4.1 Posada en marxa inicial:

  • Before starting, ensure the system is filled with fluid and properly vented to remove any air.
  • Open all necessary valves in the system.
  • Apply power to the pump. The pump should start circulating fluid.
  • Comproveu si hi ha sorolls o vibracions inusuals.

4.2 Speed Adjustment:

The Wilo Top S 2 x 40 features two pre-selectable speed stages. These can be adjusted manually to optimize flow rate and energy consumption for your specific hydronic system requirements. Consult your system design for the appropriate speed setting.

4.3 Funcionament normal:

The pump is designed for continuous operation within its specified temperature range of -20°C to +130°C. Monitor the system for consistent performance and absence of leaks.

5. Manteniment

The Wilo Top S 2 x 40 wet rotor design is largely maintenance-free. However, periodic checks are recommended to ensure optimal performance and longevity.

5.1 Regular Checks:

  • Inspecció visual: Periodically inspect the pump for any signs of leaks, corrosion, or damage to the housing or electrical connections.
  • Soroll i vibració: Listen for any unusual noises or excessive vibrations, which could indicate a problem.
  • Pressió del sistema: Ensure the system pressure remains within the recommended operating range.

5.2 Neteja:

Keep the exterior of the pump clean and free of dust and debris to ensure proper heat dissipation.

5.3 Winterization:

If the pump is installed in an unheated area subject to freezing temperatures, ensure the system is properly drained or protected with antifreeze to prevent damage.

6. Solució De Problemes

This section provides solutions to common issues you might encounter with your Wilo circulating pump. For complex problems, contact a qualified technician.

ProblemaCausa possibleSolució
La bomba no arrencaSense font d'alimentació
Motor incapat
Cablejat incorrecte
Comproveu el disjuntor/fusible
Poseu-vos en contacte amb el tècnic de servei
Verify wiring with diagram
Baix cabalAire al sistema
Partially closed valves
Clogged impeller/piping
Configuració de velocitat incorrecta
Sistema de ventilació
Open all valves
Inspect and clean system
Ajusta la configuració de velocitat
Excés de soroll/vibracióAire al sistema
Muntatge solt
Foreign object in pump
Vent system thoroughly
Premeu els cargols de muntatge
Poseu-vos en contacte amb el tècnic de servei
Fuita a les connexionsLoose flange bolts
Junta danyada
Tighten bolts evenly
Substituïu la junta

7. Especificacions

Detailed technical specifications for the Wilo Top S 2 x 40 Circulating Pump, Model 2067579.

AtributValor
Número de model2067579
FabricantWilo
Pes de l'article45.8 lliures
Dimensions del paquet18.9 x 16 x 13 polzades
MaterialPolypropylene, Stainless Steel
Font d'alimentacióAC/DC
Voltage115 Volts
Quantitat de paquet d'articles1
Permitted Temperature Range-20°C to +130°C (short-term to +140°C)
Shutoff Head40 peus
Flange RequirementUses 4 Bolt 2-Inch HV flanges (not included)

8. Garantia i Suport

8.1 Informació sobre la garantia:

Wilo Commercial Building Services products, including this circulating pump, come with a Garantia limitada d'2 any from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. Please retain your proof of purchase for warranty claims.

8.2 Atenció al client:

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Wilo customer service. Have your pump model number (2067579) and date of purchase ready when contacting support.

You can find contact information for Wilo customer service on their official weblloc web o a través del vostre distribuïdor local.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.