Fluke TL175

Manual d'usuari dels cables de prova Fluke TL175 TwistGuard

Model: TL175

1. Introducció

The Fluke TL175 TwistGuard Test Leads are designed for electrical measurement applications, offering enhanced safety and versatility. These test leads feature an adjustable tip shroud mechanism and a WearGuard lead wire wear indication system, ensuring reliable performance and user safety across various measurement environments. They are compatible with all instruments that accept standard 4mm shrouded banana plugs.

2. Informació de seguretat

WARNING: To prevent possible electrical shock, fire, or personal injury:

  • Always use the test leads with the appropriate safety category rating for the measurement environment.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged or if the inner contrasting color of the WearGuard system is exposed.
  • Ensure the test lead tips are fully inserted into the measurement device.
  • No apliqueu més del volum nominaltage, as marked on the test leads.
  • Keep fingers behind the finger guards on the probes during measurements.
  • Tingueu precaució quan treballeu amb voltagper sobre de 30 V CA RMS, 42 V pic o 60 V CC. Aquests voltagsuposen un risc de xoc.

3. Característiques del producte

  • TwistGuard Extendable Tip Shroud: Patented design allows users to twist the probe handle to extend or retract the tip shroud, reducing tip exposure for higher safety categories (CAT III, CAT IV) and providing full tip exposure for lower categories (CAT II).
  • WearGuard Lead Wire Indication: Each test lead features two layers of silicone insulation. If the outer layer is nicked or scuffed, the inner contrasting color becomes visible, indicating the need for replacement.
  • Double Insulated Silicone Leads: Designed to withstand high temperatures and maintain flexibility in cold conditions.
  • Extra-Heavy Duty Strain Relief: Reinforced strain relief on both probe-end and plug-end for enhanced durability, tested beyond 30,000 bends.
  • Universal Input Plugs: Compatible with all instruments that accept standard 4mm shrouded banana plugs.
  • Removable 4mm Lantern Tips: Includes removable tips that thread onto the lead tip for versatile connections.
Fluke TL175 TwistGuard Test Leads

Figura 1: Mésview of Fluke TL175 TwistGuard Test Leads, showing the red and black leads with their respective probe tips and banana plugs.

4. Configuració i instal·lació

  1. Inspect Leads: Before connecting, visually inspect both test leads for any signs of damage, cuts, or exposed inner insulation. If damage is found, replace the leads immediately.
  2. Connectar a l'instrument: Insert the shrouded banana plugs (black for common, red for voltage/current) firmly into the corresponding input jacks of your multimeter or test instrument. Ensure a secure connection.
    Fluke TL175 Test Leads connected to a multimeter

    Figure 2: Fluke TL175 Test Leads properly connected to a digital multimeter.

  3. Adjust TwistGuard Shroud: The TwistGuard feature allows you to adjust the exposed tip length.
    • For CAT II measurements (e.g., wall outlets), twist the probe handle to fully expose the 19mm tip.
    • For CAT III or CAT IV measurements (e.g., circuit breaker panels, main service), twist the probe handle to retract the shroud, exposing only the 4mm tip for increased safety.
      Hand demonstrating the TwistGuard feature on a Fluke TL175 test lead

      Figure 3: A hand twisting the probe handle to adjust the TwistGuard tip shroud.

  4. Attach Lantern Tips (Optional): If your application requires a different connection type, the included 4mm lantern tips can be threaded onto the probe tips.

5. Instruccions de funcionament

Once properly connected and adjusted, the Fluke TL175 Test Leads function as standard test probes for your electrical measurements. Always refer to your multimeter's instruction manual for specific measurement procedures.

  • Voltage Mesura: Seleccioneu el vol adequattage range on your multimeter. Ensure the TwistGuard shroud is set for the correct safety category. Place the black probe on the common or ground point and the red probe on the point to be measured.
  • Mesura actual: For current measurements, ensure the red lead is connected to the correct current input jack on your multimeter (e.g., 10A or mA). The circuit must be broken to insert the meter in series.
  • Resistance/Continuity: Select the resistance or continuity function. The leads can be used to test circuit continuity or component resistance.
Fluke TL175 Test Lead being used to measure in a circuit breaker panel

Figure 4: Using a Fluke TL175 Test Lead in a circuit breaker panel, demonstrating a CAT IV application with the shroud retracted.

Fluke TL175 Test Leads being used to test an electrical outlet

Figure 5: Fluke TL175 Test Leads used to test an electrical outlet, suitable for CAT II applications with tips fully exposed.

6. Manteniment

  • Neteja: Clean the test leads with a damp drap i detergent suau. No utilitzeu netejadors abrasius ni dissolvents.
  • Inspecció: Regularly inspect the leads for any signs of wear or damage, especially the WearGuard insulation. If the inner contrasting color is exposed, the leads are compromised and should be replaced to maintain safety.
  • Emmagatzematge: Store the test leads in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid sharp bends or kinks in the cables.

7. Solució De Problemes

  • Sense lectura o lectura intermitent:
    • Ensure the banana plugs are fully inserted into the multimeter.
    • Check for visible damage to the lead insulation or connectors.
    • Perform a continuity test on the leads themselves by touching the tips together. If no continuity, the leads may be internally broken and require replacement.
  • Lectures inexactes:
    • Verify the multimeter is set to the correct function and range.
    • Ensure the test lead tips are making good contact with the circuit points.
    • Check for corrosion or dirt on the probe tips or banana plugs.

8. Especificacions

CaracterísticaEspecificació
Número de modelTL175
Classificació de seguretatCAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum, Pollution Degree 2
Exposed Probe Tip Length19mm to 4mm (0.75" to 0.16") adjustable
Material del cable de plomDouble Insulated Silicone
Temperatura de funcionament-20 a 55 °C (-4 a 131 °F)
Altitud2000m (6,562')
ComplimentEN61010-031
Dimensions del producte10 x 3 x 2 polzades
Pes de l'article120 grams (4.23 unces)

Què hi ha a la caixa:

  • Fluke TL175 TwistGuard Test Leads (Red and Black)
  • Removable 4mm Lantern Tips

9. Garantia i Suport

The Fluke TL175 TwistGuard Test Leads come with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims, technical assistance, or further information, please contact Fluke Corporation customer support or visit the official Fluke weblloc.

Fabricant: Fluke Corporation

Data de primera disponibilitat: 1 de juny de 2011

Documents relacionats - TL175

Preview Multímetre digital Fluke 179: Guia de manteniment i servei de camp
Descobreix el multímetre digital de veritable valor rms Fluke 179, dissenyat per a un manteniment elèctric i de climatització eficient. Aprèn sobre les seves característiques, especificacions i accessoris recomanats per a un servei de camp fiable.
Preview Manual d'usuari dels multímetres digitals Fluke 15B+/17B+/18B+
Manual d'usuari complet per als multímetres digitals Fluke 15B+, 17B+ i 18B+, que cobreix les característiques, el funcionament, la seguretat, el manteniment i les especificacions. Aquest document proporciona instruccions detallades per utilitzar els multímetres per a diverses mesures elèctriques.
Preview Multímetres digitals de la mida d'un palmell Fluke 106/107: especificacions tècniques i característiques
Especificacions tècniques detallades, aspectes destacats del producte i informació general per als multímetres digitals de mida palmell Fluke 106 i 107. Coneix les seves especificacions elèctriques, precisió, característiques i equips inclosos.
Preview Multímetre digital de mà Fluke 107 CAT III: especificacions tècniques
Especificacions tècniques detallades, característiques i informació general del multímetre digital portàtil Fluke 107 CAT III. Inclou mesures elèctriques, classificacions de seguretat i detalls de comanda.
Preview Kit adaptador Fluke FEV100 per a estacions de càrrega de vehicles elèctrics: dades tècniques i especificacions
Exploreu les especificacions tècniques, les característiques i els procediments de prova del kit d'adaptador Fluke FEV100, dissenyat per provar estacions de càrrega de vehicles elèctrics (EVSE) de manera segura i eficient. Inclou informació de seguretat, compatibilitat i detalls de comanda.
Preview Multímetre Fluke 110 True-RMS: especificacions tècniques i característiques
Especificacions i característiques detallades del multímetre compacte Fluke 110 de veritable RMS, dissenyat per a una instal·lació i resolució de problemes elèctrics precisos. Inclou precisió, classificacions de seguretat i accessoris inclosos.