Red Lion RL12G05-2W2V

Red Lion RL12G05-2W2V 4-inch Submersible Deep Well Pump

Model: RL12G05-2W2V

Producte acabatview

The Red Lion RL12G05-2W2V is a 4-inch submersible deep well pump designed for reliable water supply from wells. This 1/2 HP, 2-wire, 230-volt pump delivers a maximum of 12 GPM and has a maximum shut-off head of 212 feet. It features a durable stainless steel pump casing, thermoplastic discharge, and motor bracket. The pump includes a built-in suction screen and check valve for enhanced performance and longevity. Its 2-wire, 230-volt motor integrates the control mechanism, eliminating the need for an external control box.

Red Lion RL12G05-2W2V 4-inch Submersible Deep Well Pump

Image: Red Lion RL12G05-2W2V 4-inch Submersible Deep Well Pump.

Característiques clau

  • Disseny submergible: This 3.9-inch diameter submersible pump is designed for 4-inch diameter driven wells or larger. It is NSF/ANSI 372 certified for potable water applications.
  • Vàlvula de retenció integrada: Features a built-in check valve to prevent rapid cycling and extend motor life.
  • Suction Screen: Includes a built-in suction screen to protect impellers from debris.
  • Rendiment: Delivers 12 Gallons Per Minute (GPM) at 30 PSI from a depth of 40 feet, with a maximum shut-off head of 212 feet.
  • 2-Wire Technology: Utilizes 2-wire technology (plus ground), with the switch mechanism integrated into the pump, eliminating the need for an external control box.
  • Construcció duradora: Constructed with a stainless steel body and glass-filled thermoplastic impellers for long-lasting performance.
Diagram showing internal features of the Red Lion RL Series Deep Well Submersible Pump, including thermoplastic discharge head, built-in check valve, multiple-stage design, stainless steel body, glass-filled thermoplastic impeller, and built-in suction screen.

Image: Internal features of the RL Series Deep Well Submersible Pump.

Red Lion RL12G 2-Wire Pump with text indicating NSF/ANSI 372 certification for clean drinking water.

Image: NSF/ANSI 372 certification for clean drinking water.

Model Number Deciphering

Understanding the model number helps identify the specific characteristics of your Red Lion deep well submersible pump.

Diagram explaining Red Lion RL Series model number breakdown: RL 12G 05-2W 1V, indicating Rating (GPM), Horsepower, Wires, and Voltage.

Image: How to decipher the RL Series model number.

Especificacions

EspecificacióDetall
Número de modelRL12G05-2W2V (14942402)
Potència (HP)1 / 2 HP
Voltage230 Volts
Configuració del cable2 cables (més terra)
Caudal màxim12 galons per minut (GPM)
Alçada màxima d'elevació (tancament)212 peus
Córrer Amps6 Amps
Mida de descàrrega1-1/4-inch FNPT
Diàmetre de la bomba3.9 polzades
Dimensions del producte (L x A x A)3.9 cm de llargada x 3.9 cm d'amplada x 22.5 cm d'alçada
Pes de l'article20 lliures
MaterialStainless Steel, Thermoplastic
CertificacionsCSA, UL listed (USA and Canada), NSF/ANSI 372

Dimensions

Diagram showing the dimensions of the RL12G05-2W2V Deep Well Submersible Pump. Height (D) 22.49 inches, Length of Pump (C) 12.73 inches, Length of Motor (B) 9.51 inches, Diameter 3.9 inches.

Image: Detailed dimensions of the pump.

Gràfic de rendiment

Performance chart for Red Lion RL12G05-2W2V pump, showing Gallons Per Minute (GPM) at various depths to water and discharge pressures (PSI), along with shut-off values.

Image: Pump performance chart indicating GPM at different depths and pressures.

Informació de seguretat

Always prioritize safety during installation, operation, and maintenance. Read all instructions carefully before proceeding. Electrical work should only be performed by qualified personnel.

  • Desconnecteu l'alimentació abans de fer servei a la bomba.
  • Assegureu-vos de posar a terra correctament per evitar descàrregues elèctriques.
  • Utilitzeu l'equip de protecció individual (EPI) adequat durant la instal·lació i el manteniment.
  • Verify that the well casing is free of debris before lowering the pump.
  • Do not operate the pump dry; ensure it is fully submerged in water.
Image showing a person working with electrical wires, with text 'Electrical experience required. Hiring an electrician or qualified installer is recommended.'

Image: Electrical experience is required for installation.

Instal·lació i Configuració

Proper installation is crucial for the efficient and safe operation of your deep well pump. This section provides general guidelines. Refer to the included installation manual for detailed, step-by-step instructions.

  1. Preparació del pou: Ensure the well is clean and free of obstructions. The pump requires a 4-inch or larger well casing.
  2. Connexió elèctrica: Connect the pump's 2-wire (plus ground) lead wires to the power supply. Use the provided waterproof splice kit for secure and watertight connections. No external control box is needed for this 2-wire pump.
  3. Tuberia: Attach the discharge pipe to the pump's 1-1/4-inch FNPT discharge. Use appropriate pipe and fittings, ensuring all connections are watertight. Consider using a torque arrestor to prevent pump rotation within the well.
  4. Lowering the Pump: Carefully lower the pump into the well using a safety rope or cable attached to the pump. Ensure the pump is suspended at the recommended depth, typically 5-10 feet above the bottom of the well and below the dynamic water level.
  5. Surface Connections: Connect the discharge pipe to your pressure tank, pressure switch, and other plumbing components. Install a check valve if not already integrated into the pump or system.
  6. System Priming: Once installed, prime the system according to your pressure tank and plumbing setup.
  7. Encès: Restore power and check for proper operation and leaks.
Diagram illustrating a typical deep well pump installation setup, including the pump, well, torque arrester, discharge pipe, pitless adapter, frost line, pressure switch, tank, and pressure gauge leading to the home.

Image: Typical deep well pump installation diagram.

Image showing plumbing connections with wrenches, illustrating piping installation tips.

Image: Piping installation tips.

Instruccions de funcionament

Once properly installed, the Red Lion RL12G05-2W2V pump operates automatically in conjunction with your pressure switch and pressure tank to maintain water pressure in your system.

  1. Posada en marxa inicial: After installation and priming, turn on the power supply to the pump. The pump will begin to fill the pressure tank and build system pressure.
  2. Funcionament automàtic: The pressure switch will automatically turn the pump on when system pressure drops below the cut-in setting and turn it off when the pressure reaches the cut-out setting.
  3. Seguiment: Periodically check the pressure gauge to ensure the pump is maintaining consistent pressure within the desired range.
  4. Ús d'aigua: The pump is designed to handle typical household water demands. Avoid excessive continuous operation, which can lead to overheating.

Manteniment

Regular maintenance helps ensure the longevity and optimal performance of your deep well pump.

  • Inspecció anual: Have a qualified professional inspect the pump and well system annually.
  • Check Pressure Tank: Verify the air pre-charge in your pressure tank periodically, typically once a year, with the pump off and system drained.
  • Control de la qualitat de l'aigua: If water quality changes (e.g., sediment, discoloration), it may indicate an issue with the well or pump.
  • Escolteu els sorolls inusuals: Any new or unusual noises from the pump or system should be investigated promptly.
  • Protegir de la congelació: Ensure all exposed piping and components are protected from freezing temperatures.

Resolució de problemes

This section provides common troubleshooting steps for issues you might encounter. For complex problems, contact a qualified pump technician.

ProblemaCausa possibleSolució
La bomba no funcionaNo power, tripped breaker, faulty pressure switch, motor issueCheck power supply and breaker. Inspect pressure switch. Consult technician for motor issues.
Baixa pressió d'aiguaLow well water level, clogged screen, pipe leak, faulty pressure tankCheck well level. Clean suction screen. Inspect plumbing for leaks. Check pressure tank pre-charge.
La bomba circula amb massa freqüènciaWaterlogged pressure tank, small leak in system, faulty check valveCheck pressure tank pre-charge. Locate and repair leaks. Inspect or replace check valve.
No es lliura aiguaPump not submerged, air in system, clogged intake, pump failureVerify pump depth. Bleed air from system. Clear intake. Consult technician.

Informació de la garantia

The Red Lion RL12G05-2W2V Submersible Deep Well Pump comes with a Garantia del fabricant de 3 anys. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the documentation included with your product or contact Red Lion customer support.

Suport i Contacte

For further assistance, technical support, or inquiries regarding your Red Lion pump, please use the following resources:

  • Recursos en línia: Visita el Red Lion Store on Amazon per obtenir informació i recursos addicionals sobre el producte.
  • Atenció al client: If Amazon.com is the seller, your product is covered by the terms outlined in our manual. Our staff can assist with troubleshooting or installation.
  • Reclamacions de garantia: For items purchased within 30 days, refer to Amazon's return policy. After 30 days, if Amazon.com is the seller, refer to your owner's manual for warranty information. If another company is the seller, contact them directly.

Vídeos útils

Red Lion: Trusted for Generations

Vídeo: Un overview of the Red Lion brand's history and commitment to quality in water movement solutions.

RL12G and RL22G Series Rotational View

Video: A rotational view of the RL12G and RL22G series submersible pumps, showcasing the exterior design and components.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.