Ortho 841010

Ortho Dial N Spray Hose-End Sprayer Instruction Manual

Model: 841010 | Brand: Ortho

Producte acabatview

The Ortho Dial N Spray Hose End Sprayer is designed for easy and precise application of liquid concentrates such as weed killers, insect killers, fungicides, and fertilizers. It eliminates the need for manual mixing and measuring, providing a clean and efficient solution for your lawn and garden care needs.

Ortho Dial N Spray Hose-End Sprayer

Figure 1: Ortho Dial N Spray Hose-End Sprayer

Característiques principals:

  • Extended Grip Handle: Designed for comfortable handling and to keep hands dry during application.
  • 14 Dilution Settings: Automatically mixes concentrates from 1 teaspoon to 8 ounces per gallon of water.
  • 3 patrons de polvorització: Offers Broadcast, Jet, and Shower patterns for versatile application.
  • Anti-Backflow Device: Prevents product from re-entering water systems, ensuring safety.
  • Easy Hose Connection: Features a rotating connector for simple attachment to a standard garden hose.
Ortho Dial N Spray features: Extended Grip, Hose Connection, Trigger, Jar with Suction Tube

Figura 2: Detallada view of sprayer features.

Instruccions de configuració

Follow these steps to prepare your Ortho Dial N Spray for use:

  1. Prepare Concentrate: Ensure you have the liquid concentrate you wish to apply (e.g., weed killer, insect killer, fungicide, fertilizer).
  2. Fill Sprayer Jar: Unscrew the sprayer head from the jar. Pour the liquid concentrate directly into the sprayer jar. DO NOT add water to the jar. The sprayer automatically mixes the product with water from the hose.
  3. Sprayer jar with ounce measurements

    Figure 3: Sprayer jar with measurement markings.

  4. Attach Sprayer Head: Screw the sprayer head back onto the jar securely. Ensure the suction tube is properly inserted into the concentrate.
  5. Connecteu-vos a la mànega: Attach your garden hose to the hose connector at the end of the sprayer. Rotate the connector until it is tightly secured.
How to use Ortho Dial N Spray steps: Set Dial, Pour Liquid, Screw Applicator, Connect to Hose, Squeeze Trigger

Figure 4: Visual guide for sprayer setup and use.

Instruccions de funcionament

The Ortho Dial N Spray offers precise control over dilution and spray pattern:

  1. Set Dilution: Refer to your concentrate's label for the recommended dilution rate. Rotate the dial on top of the sprayer to select the appropriate setting (from 1 tsp to 8 oz per gallon).
  2. 14 Dial Settings for automatic mixing from 1 tsp to 8 oz per gallon of water

    Figure 5: Dial settings for precise dilution.

  3. Select Spray Pattern: Choose from three distinct spray patterns by rotating the nozzle at the front of the sprayer:
    • Transmissió: Ideal for covering large, open areas with an even flat fan spray.
    • Jet: Provides a high-pressured stream, perfect for reaching high places (up to 25 feet) or for tough rinsing jobs.
    • Dutxa: Delivers a gentle shower, suitable for delicate vegetation and flowers.
  4. Three spray patterns: Shower, Jet, Broadcast

    Figure 6: Different spray patterns for various applications.

  5. Comenceu a ruixar: Turn on your water hose. Aim the sprayer at the target area and squeeze the ergonomically designed trigger to begin spraying.
  6. Person spraying lawn with Ortho Dial N Spray

    Figure 7: Applying liquid product with the sprayer.

  7. Stop Spraying: Deixeu anar el gallet per aturar el flux.

Aplicacions:

The Ortho Dial N Spray is suitable for applying various liquid products:

  • Herbicides
  • Insect killers
  • Fungicides
  • Fertilitzants
Use to apply liquid products: Weed killers, Insect killers, Fungicides, Fertilizers

Figure 8: Types of liquid products compatible with the sprayer.

Manteniment

Proper cleaning of your Ortho Dial N Spray will ensure its longevity and optimal performance:

  1. Empty Remaining Product: After each use, if there is any concentrate remaining in the jar, pour it back into its original container. The anti-backflow device ensures the concentrate remains undiluted in the jar.
  2. Rinse Jar: Rinse the sprayer jar thoroughly with water.
  3. Neteja del polvoritzador: Reattach the sprayer head to the rinsed jar. Connect the hose and spray clean water through the unit for approximately 30 seconds to clear any residue from the internal mechanisms and nozzle.
  4. Botiga: Store the sprayer in a cool, dry place away from direct sunlight.

Resolució de problemes

If you encounter issues with your Ortho Dial N Spray, consider the following:

  • Sense esprai o esprai feble:
    • Check hose connection for kinks or blockages.
    • Ensure water pressure from the hose is adequate.
    • Verify the dilution dial is not set to

      Ask a question about this manual

      Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.