Robertshaw 700-506

Robertshaw 700-506 Gas Valve Instruction Manual

Model: 700-506

1. Producte acabatview

The Robertshaw 700 series gas valve uni-kits are designed for use in intermittent pilot, direct spark, and hot surface ignition applications. This model, the 700-506, is a fast-opening gas valve with a capacity of up to 200,000 BTUH.

It integrates a manual valve, a pilot valve, and a main gas pressure regulator into a single unit. These valves are suitable for various residential and commercial heating systems, including central heating units, wall heaters, boilers, and mobile home furnaces.

Les característiques clau inclouen:

  • Normally closed solenoid for safety.
  • Compact size with high flow rates.
  • Standard NEMA terminals for electrical connections.
  • Inlet filtered screen to prevent debris entry.
  • Compatibility with various gas types: natural, manufactured, mixed, LP, and LP/air mixtures.
Vàlvula de gas Robertshaw 700-506

Image 1.1: Robertshaw 700-506 Gas Valve. This image displays the main unit of the gas valve, highlighting its compact design and connection points.

2. Informació de seguretat

ADVERTIMENT: Una instal·lació, un ajust, una alteració, un servei o un manteniment incorrectes poden causar danys materials, lesions personals o la mort. Llegiu atentament les instruccions d'instal·lació, funcionament i manteniment abans d'instal·lar o fer el manteniment d'aquest equip.

  • La instal·lació i el servei han de ser realitzats per un instal·lador qualificat, agència de servei o proveïdor de gas.
  • Always shut off the main gas supply before attempting any installation, service, or maintenance.
  • Check for gas leaks after any service or installation using a soap solution; never use an open flame.
  • Assegureu-vos una ventilació adequada durant el funcionament.
  • No salteu ni tamper amb dispositius de seguretat.

This manual provides general guidelines. Always refer to the specific appliance manufacturer's instructions and local codes for complete safety and installation procedures.

3. Contingut del paquet

En obrir el paquet, comproveu que hi hagi tots els components:

  • Robertshaw 700-506 Gas Valve Unit
  • Product & Instructions Guide (this document and supplementary materials)
  • Necessary parts for conversion to direct spark or hot surface applications (as specified in the included guide).

4. Especificacions

Especificació Detall
Número de model 700-506
Material Metall
Acabat exterior Acer inoxidable
Color Plata
Dimensions de l'article (L x A x A) 3 x 3 x 4.13 polzades
Pes de l'article 2 lliures
Mida de la connexió d'entrada 0.5 polzades
Tipus de connexió d'entrada Estàndard
Mida de connexió de presa 3 polzades
Nombre de Ports 1
Tipus de connector Amb brides
Especificació Met ASME, CSA, UL
Gas Types Supported Natural, Manufactured, Mixed, LP, LP/Air mixtures

5. Instal·lació i configuració

Important: Installation of this gas valve must be performed by a qualified and licensed professional in accordance with all local and national codes and regulations.

  1. Preparació:
    • Ensure the main gas supply to the appliance is turned off.
    • Desconnecteu l'alimentació elèctrica de l'aparell.
    • Ventila bé la zona.
  2. Removal of Old Valve (if applicable):
    • Carefully disconnect gas lines and electrical wiring from the existing valve.
    • Remove the old valve, taking note of its orientation and connections.
  3. Mounting the New Valve:
    • Mount the Robertshaw 700-506 gas valve in the same orientation as the original valve, ensuring it is securely fastened.
    • The valve is designed with easily accessible wiring connections, manual selector, and adjustments.
  4. Gas Line Connections:
    • Connect the gas supply lines to the inlet and outlet ports of the new valve. Use appropriate pipe sealant on all threaded connections.
    • The inlet connection size is 0.5 inches, and the outlet connection size is 3 inches. Ensure compatible fittings are used.
  5. Cablejat elèctric:
    • Connect the electrical wiring to the standard NEMA terminals on the valve according to the appliance manufacturer's wiring diagram.
  6. Prova de fuites:
    • Enceneu lentament el subministrament principal de gas.
    • Apply a soap solution to all gas connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately and tighten connections until no bubbles appear.
    • No utilitzeu mai una flama oberta per comprovar si hi ha fuites de gas.
  7. Initial Startup and Adjustment:
    • Refer to the appliance manufacturer's instructions for specific startup procedures and pilot light ignition.
    • Adjust the main gas pressure regulator as needed, following the appliance specifications.

This uni-kit includes all necessary parts and instructions for conversion to direct spark or hot surface applications. Consult the supplementary instructions guide for detailed conversion procedures.

6. Funcionament

The Robertshaw 700-506 gas valve operates in conjunction with your heating appliance's control system to regulate gas flow to the main burner and pilot light.

  • Manual Valve: This allows for manual shut-off of the gas supply to the entire valve. Ensure it is in the "ON" position for normal operation.
  • Pilot Valve: Controls the gas flow to the pilot light. For systems with standing pilots, this valve must be open for the pilot to ignite and remain lit. For intermittent pilot or direct spark systems, the pilot valve opens as part of the ignition sequence.
  • Main Gas Pressure Regulator: Maintains a consistent gas pressure to the main burner for efficient combustion.
  • Fast Opening Feature: This valve is designed for quick response, allowing for rapid gas flow when called for by the thermostat or control system.

Always follow the operating instructions provided by the manufacturer of your specific heating appliance for proper startup, shutdown, and general use.

7. Manteniment

Regular maintenance helps ensure the safe and efficient operation of your gas valve and heating system. All maintenance should be performed by a qualified service technician.

  • Inspecció anual: Have a qualified technician inspect the gas valve and entire heating system annually. This includes checking for leaks, proper gas pressure, and overall valve function.
  • Inlet Filtered Screen: The valve features an inlet filtered screen. During annual inspections, this screen should be checked for any debris or blockages and cleaned if necessary to maintain proper gas flow.
  • Neteja: Mantingueu l'exterior de la vàlvula net i lliure de pols i deixalles. No utilitzeu productes químics agressius ni netejadors abrasius.

Do not attempt to disassemble or repair the gas valve yourself. Contact a qualified service professional for any issues beyond routine cleaning and inspection.

8. Solució De Problemes

If you experience issues with your heating appliance, consider the following common troubleshooting steps. For safety, always contact a qualified technician for diagnosis and repair if you are unsure or suspect a gas leak.

  • No Heat / Burner Not Igniting:
    • Check if the main gas supply is turned on.
    • Verify that the manual valve on the 700-506 is in the "ON" position.
    • Ensure electrical power to the appliance is active.
    • Comproveu la configuració del termòstat.
    • Inspect the pilot light (if applicable). If it's out, follow your appliance's instructions for relighting.
  • Pilot Light Not Staying Lit:
    • This can indicate an issue with the thermocouple/thermopile or the pilot assembly.
    • Ensure the pilot flame is strong and consistently engulfing the thermocouple/thermopile.
    • A qualified technician should inspect and replace faulty components.
  • Olor de gas:
    • If you smell gas, immediately turn off the main gas supply, open windows and doors, evacuate the premises, and call your gas company or a qualified technician from a safe location.
    • Do not operate any electrical switches or phones inside the building.

9. Conversió de tipus de gas

The Robertshaw 700-506 gas valve is compatible with various gas types. However, specific conversion kits are required to switch between natural gas and LP gas.

  • To convert the valve for use with Gas Natural, use Robertshaw conversion kit 1751-003.
  • To convert the valve for use with Gas LP, use Robertshaw conversion kit 1751-013.

ADVERTIMENT: Gas type conversion must only be performed by a qualified service technician. Incorrect conversion can lead to unsafe operation, property damage, personal injury, or loss of life.

10. Garantia i Suport

For information regarding the product warranty, please refer to the warranty documentation included with your purchase or visit the official Robertshaw website. For technical support, replacement parts, or service inquiries, please contact Robertshaw customer service or a qualified service professional.

Podeu trobar més informació i dades de contacte a Botiga Robertshaw a Amazon o la seva empresa oficial weblloc.

© 2026 Robertshaw. Tots els drets reservats. Informació subjecta a canvis sense previ avís.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.