Paradoxa SP5500

Paradox Spectra SP5500 Control Panel User Manual

Model: SP5500 | Marca: Paradoxa

Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Paradox Spectra SP5500 wired control panel. The SP5500 is a robust security solution featuring 5 on-board zones, expandable up to 32 zones, 2 programmable outputs (PGMs), support for 2 partitions, and up to 32 user codes. It includes an integrated Contact ID protocol transmitter and supports remote programming via WinLoad software. This guide is intended to assist qualified installers and end-users in understanding and utilizing the system effectively.

Configuració i instal·lació

Installation of the Paradox Spectra SP5500 control panel should be performed by a qualified security professional. Incorrect installation can lead to system malfunction or compromise security. Ensure all local electrical codes and safety regulations are followed.

1. Unboxing i Inspecció

  • Traieu amb cura tots els components de l'embalatge.
  • Verify that all items listed in the packing slip are present.
  • Inspect the control panel and other components for any signs of physical damage.

2. Mounting the Control Panel

Select a secure, dry, and easily accessible location for the control panel enclosure, typically in a utility closet or basement. Ensure the location is not exposed to extreme temperatures or moisture.

  • Fixeu la carcassa de manera segura a la paret amb els elements de fixació adequats.
  • Ensure adequate space for wiring and future maintenance.

3. Connexions de cablejat

Consulteu el diagrama següent per obtenir una visió generalview of the control panel's circuit board and terminal connections. All wiring should be performed with the main power supply disconnected.

Paradox Spectra SP5500 Control Panel Circuit Board with dimensions

Figura 1: Acabatview of the Paradox Spectra SP5500 control panel circuit board, showing various components, terminals, and dimensions (10.8 cm / 4.25 inches height, 20.3 cm / 8 inches width). This image illustrates the layout for wiring connections.

  • Connexió d'alimentació: Connect the AC transformer to the designated AC terminals. Ensure the transformer is rated correctly for the system.
  • Còpia de seguretat de la bateria: Connect a rechargeable 12V backup battery to the battery terminals. This battery provides power during AC failures.
  • Zone Wiring: Connect detection devices (e.g., motion sensors, door/window contacts) to the numbered zone terminals. Each zone requires proper end-of-line resistor termination.
  • Connexió del teclat: Connect keypads to the data bus terminals (typically labeled RED, BLK, GRN, YEL).
  • PGM Outputs: Utilize the Programmable Gate Module (PGM) outputs for controlling external devices such as sirens, strobes, or access control components.
  • Comunicació: Connect to a telephone line for Contact ID reporting if required.

4. Initial Power-Up and Programming

After all wiring is complete and verified, connect the AC power. The system will perform an initial self-test. Refer to the detailed programming guide for configuring zones, user codes, system options, and communication settings. Remote programming can be performed using Paradox WinLoad software.

Instruccions de funcionament

This section covers basic user operations. For advanced features, consult the full user manual or your installer.

1. Armament del sistema

  • Mantenir-se armant: Premeu el botó [STAY] button, then enter your 4-digit user code. This arms the perimeter zones while allowing movement within the protected area.
  • Armament fora: Premeu el botó [BRAÇ] button, then enter your 4-digit user code. This arms all zones, including interior motion detectors. Exit the premises within the programmed exit delay time.
  • Force Arming: If a zone is open, some systems allow force arming. Consult your installer for this feature.

2. Desactivació del sistema

To disarm the system, enter your 4-digit user code. This will silence any alarms and disarm all armed zones.

3. Bypassing Zones

To temporarily disable a specific zone (e.g., for an open window), press the [BYP] button, enter your user code, then enter the 2-digit zone number(s) to bypass. Press [ENTRAR] to confirm. Bypassed zones are automatically unbypassed when the system is disarmed.

4. Canvi de codis d'usuari

Consult your installer or the detailed programming manual for instructions on how to add, delete, or change user codes. This typically involves entering a master code followed by specific programming commands.

Manteniment

Regular maintenance ensures the optimal performance and reliability of your security system.

  • Comprovació de la bateria: The system's backup battery should be checked annually by a qualified technician. Replace the battery every 3-5 years, or as recommended by the manufacturer, to ensure proper operation during power outages.
  • Prova del sistema: Periodically test your alarm system (e.g., monthly) by arming it and triggering a zone. Inform your monitoring station (if applicable) before testing to avoid false dispatches.
  • Neteja: Keep the control panel and keypads clean and free of dust. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
  • Inspecció del sensor: Visually inspect all sensors (motion detectors, door/window contacts) for any obstructions or damage.

Resolució de problemes

This section addresses common issues. For complex problems, contact your security system installer or Paradox technical support.

  • System Not Arming:
    • Check if any zones are open (e.g., door/window ajar). Close all zones or bypass the open zone.
    • Ensure the system is not displaying a trouble condition.
  • Trouble Light On:
    • Premeu el botó [TROUBLE] button on your keypad to view the specific trouble condition (e.g., AC failure, battery low, communication failure).
    • Address the indicated issue. For AC failure, check the power supply. For low battery, consider battery replacement.
  • Falses alarmes:
    • Identify the zone that triggered the alarm.
    • Check for environmental factors (e.g., drafts, pets, loose objects) affecting motion detectors.
    • Inspect sensors for damage or improper installation.
  • El teclat no respon:
    • Check power to the control panel.
    • Ensure keypad wiring is secure.

Especificacions

CaracterísticaDetall
FabricantParadoxa
Número de modelSP5500 (3700774000387)
Dimensions (producte)28 x 26 x 10 cm (aprox. 11 x 10.2 x 3.9 polzades)
Pes de l'article3 quilograms (aprox. 6.6 lliures)
On-board Zones5
Expandable ZonesFins a 32
Sortides PGM2
Particions2
Codis d'usuariFins a 32
Protocol de comunicacióIntegrated Contact ID transmitter
Programació a distànciaSupported via WinLoad software
Piles inclosesNo (requires separate backup battery)
Primera data disponible11 de febrer de 2015

Informació de la garantia

Paradox products are typically covered by a limited manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product. Please retain your proof of purchase. For detailed warranty information, refer to the documentation provided with your product or contact your authorized Paradox dealer or installer.

Suport

For technical assistance, advanced programming, or troubleshooting beyond the scope of this manual, please contact your authorized Paradox security system installer. They possess the expertise and tools necessary to provide comprehensive support for your SP5500 control panel. You may also visit the official Paradox website for additional resources, FAQs, and contact information for regional support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.