Santamedical SP-110

Manual d'instruccions de l'esfigmomanòmetre aneroide Santamedical Deluxe per a adults SP-110

Model: SP-110

1. Introducció

This manual provides detailed instructions for the proper use and care of your Santamedical Adult Deluxe Aneroid Sphygmomanometer, Model SP-110. This device is designed for professional and personal use to accurately measure blood pressure. Please read this manual thoroughly before use to ensure correct operation and to maintain the device's accuracy and longevity.

2. Producte acabatview i Components

The Santamedical Adult Deluxe Aneroid Sphygmomanometer is a manual blood pressure monitoring system. It includes the following components:

  • Aneroid Manometer: A precision-calibrated gauge for displaying blood pressure readings.
  • Adult Cuff: A comfortable, universal adult-sized cuff designed for upper arm placement.
  • Inflation Bulb with Air Release Valve: Used to inflate the cuff and control deflation.
  • Tubs: Connects the cuff, manometer, and inflation bulb.
  • Estoig de transport: For convenient storage and transport of the device.
Santamedical Adult Deluxe Aneroid Sphygmomanometer with carrying case

Image 2.1: The Santamedical Adult Deluxe Aneroid Sphygmomanometer, showing the cuff, manometer, inflation bulb, and carrying case.

Close-up of the Santamedical Aneroid Sphygmomanometer components

Imatge 2.2: Detallada view of the sphygmomanometer components, highlighting the latex-free bulb, precision calibrated gauge, universal adult-sized cuff, and metal body manometer.

3. Configuració

  1. Desempaquetar components: Carefully remove the sphygmomanometer, cuff, and inflation bulb from the carrying case.
  2. Connexió de tubs: Ensure all tubing connections between the cuff, manometer, and inflation bulb are secure. The manometer typically connects to one tube from the cuff, and the inflation bulb connects to the other.
  3. Preparació per a la mesura:
    • Seieu en una posició còmoda amb l'esquena recolzada i els peus a terra.
    • Recolza el braç sobre una superfície plana a l'alçada del cor.
    • Ensure you have not exercised, consumed caffeine, or smoked for at least 30 minutes prior to measurement.

4. Instruccions de funcionament

Follow these steps to accurately measure blood pressure using your Santamedical Aneroid Sphygmomanometer. A stethoscope (not included) is required to listen for Korotkoff sounds.

  1. Aplicar el maneguet:
    • Wrap the cuff firmly around your bare upper arm, approximately 1 inch (2-3 cm) above the elbow crease.
    • Ensure the artery marker on the cuff (often indicated by an arrow) is aligned with your brachial artery, which is typically on the inside of your arm.
    • The cuff should be snug but not uncomfortably tight. You should be able to slide two fingers under the cuff.
    Person applying blood pressure cuff to upper arm

    Image 4.1: Proper placement of the blood pressure cuff on the upper arm.

  2. Position the Manometer: Clip the manometer to the cuff or place it on a flat surface where it is easily visible.
  3. Inflar el maneguet:
    • Tanqueu la vàlvula d'alliberament d'aire de la bombeta d'inflat girant-la en sentit horari.
    • Rapidly pump the inflation bulb until the manometer reads approximately 20-30 mmHg above your usual systolic pressure, or until the pulse sound disappears through the stethoscope. Do not over-inflate.
    Hand inflating the blood pressure cuff bulb

    Image 4.2: Hand squeezing the inflation bulb to inflate the cuff.

  4. Deflate and Read:
    • Obriu lentament la vàlvula d'alliberament d'aire girant-la en sentit antihorari, permetent que la pressió baixi a una velocitat de 2-3 mmHg per segon.
    • Listen carefully with a stethoscope placed over the brachial artery.
    • Note the reading on the manometer when you hear the first clear, tapping sound (Systolic Pressure).
    • Continue to deflate the cuff. Note the reading when the sounds disappear completely (Diastolic Pressure).
    Hand adjusting the air release valve on the inflation bulb

    Image 4.3: Hand adjusting the air release valve for controlled deflation.

  5. Lectures de registre: Document your systolic and diastolic pressures immediately.
  6. Repeat Measurement: Wait 1-2 minutes before taking another measurement on the same arm. For best results, take two or three readings and average them.

5. Manteniment i cura

  • Neteja: Wipe the cuff with a damp cloth and mild soap. Do not immerse the cuff or manometer in water. The manometer can be cleaned with a soft, dry cloth.
  • Emmagatzematge: Store the sphygmomanometer in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Calibració: Aneroid sphygmomanometers should be checked for calibration accuracy periodically, typically every 1-2 years, or if dropped. Consult a qualified technician for calibration services.
  • Inspecció: Regularly inspect the cuff, tubing, and inflation bulb for any signs of wear, cracks, or leaks. Replace components as needed.

6. Solució De Problemes

ProblemaCausa possibleSolució
El maneguet no s'infla o s'infla lentament.Air release valve is open; loose tubing connections; leak in cuff or bulb.Ensure valve is closed tightly. Check all tubing connections. Inspect cuff and bulb for damage and replace if necessary.
Lectures inexactes o inconsistents.Improper cuff placement; rapid deflation; manometer out of calibration; patient movement/talking.Re-apply cuff correctly. Deflate at 2-3 mmHg/second. Have manometer calibrated. Ensure patient is still and quiet.
El puny es desinfla massa ràpidament.Air release valve not fully closed; leak in system.Ensure air release valve is fully closed. Check tubing and cuff for leaks.

7. Especificacions

  • Model: SP-110
  • Mètode de mesura: Manual Aneroid
  • Manòmetre: Certified 300 mmHg, no-pin stop
  • Precisió: ± 3 mmHg
  • Tipus de puny: Adult Nylon Cuff
  • Material: DEHP-free components
  • Tipus de visualització: Analògic
  • Dimensions del producte: 2.4 cm de llargada x 9 cm d'amplada x 5.3 cm de gruix
  • Pes de l'article: 12.31 unces

8. Informació de seguretat

Precaucions de seguretat importants:

  • Always ensure proper cuff placement and check for any signs of discomfort during use.
  • Consult a healthcare professional for accurate readings and guidance regarding blood pressure management.
  • This device is intended for measuring human blood pressure. Do not use it for any other purpose.
  • Mantenir fora de l'abast dels nens.
  • No intenteu reparar el dispositiu vosaltres mateixos. Contacteu amb l'assistència al client per obtenir assistència.

9. Garantia i Suport

For warranty information or technical support, please contact Santamedical customer service. Refer to the product packaging or the official Santamedical weblloc web per obtenir les dades de contacte més actualitzades.

Santamedical Customer Support:
Visit the Santamedical Store on Amazon

© 2025 Santamedical. All rights reserved.