Hager 129002

Hager 2500 Series Cylindrical Passage Lock 129002 Instruction Manual

Model: 129002

Introducció

This manual provides instructions for the proper installation, operation, and maintenance of the Hager 2500 Series Cylindrical Passage Lock, model 129002. This lock is designed for standard duty commercial applications and is suitable for doors requiring a non-locking function, allowing free passage from either side at all times.

Informació de seguretat

Always wear appropriate safety gear, such as gloves and eye protection, during installation. Ensure all tools are in good working condition. If you are unsure about any step, consult a qualified professional.

Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació:

  • Hager 2500 Series Cylindrical Passage Lock assembly (Withnell Lever Style)
  • Mecanisme de tancament
  • Strike plate (ASA Strike)
  • Cargols de muntatge
  • Operating keys (two supplied, for specific internal components, not for locking function)
  • Installation template (if included with physical product)

Configuració i instal·lació

Follow these steps for proper installation of the Hager 2500 Series Cylindrical Passage Lock.

1. Preparació de la porta

Ensure your door is prepared with the following standard dimensions:

  • Diàmetre creuat: 2-1/8 inches (54 mm) diameter
  • Edge Bore (Latch Hole): 1 inch (25 mm) diameter
  • Part posterior: 2-3/4 polzades (70 mm)

Use the provided template (if applicable) to mark and drill holes accurately. Incorrect drilling can affect lock function and security.

2. Install Latch Mechanism

  1. Insert the latch mechanism into the edge bore of the door, ensuring the bevel of the latch bolt faces the door frame.
  2. Secure the latch with the provided screws.

3. Install Lock Chassis

  1. Align the lock chassis with the cross bore, ensuring the spindle engages with the latch mechanism.
  2. Insert the exterior and interior lever assemblies.
  3. Secure the lock chassis with the through-bolts or mounting screws. The design features no exposed mounting screws for a clean appearance.

4. Install Strike Plate

  1. Mark the position for the ASA strike plate on the door frame, aligning it with the latch bolt.
  2. Chisel out the mortise for the strike plate to sit flush with the door frame.
  3. Secure the strike plate with the provided screws.
Hager 2500 Series Cylindrical Passage Lock, Withnell Lever Style, Satin Chrome Finish

Image 1: Hager 2500 Series Cylindrical Passage Lock, Withnell Lever Style, in Satin Chrome finish. This image shows the complete lever set, including both interior and exterior levers and the cylindrical chassis.

Instruccions de funcionament

The Hager 2500 Series Cylindrical Passage Lock is designed for non-locking applications. It allows free entry and exit at all times.

  • To open the door, simply depress the lever handle on either side.
  • Release the lever to allow the latch bolt to extend and secure the door in the closed position.

Nota: While two operating keys are supplied, these are typically for internal component access or specific installation adjustments, not for a locking function on a passage set. This lock does not provide security locking.

Manteniment

Regular maintenance ensures the longevity and smooth operation of your lock.

  • Neteja: Netegeu les superfícies exteriors amb un drap suau iamp cloth. Avoid abrasive cleaners or solvents, which can damage the finish.
  • Lubricació: Periodically apply a small amount of graphite-based lubricant to the latch bolt mechanism if it becomes stiff. Do not use oil-based lubricants, as they can attract dust and debris.
  • Inspecció: Annually inspect all screws and components for tightness. Tighten any loose screws to prevent excessive wear.

Resolució de problemes

ProblemaCausa possibleSolució
La palanca està rígida o té dificultat per girar.Acumulació de brutícia o manca de lubricació.Clean the mechanism and apply graphite lubricant.
El forrellat no es retrau completament.Misalignment of lock components or strike plate.Check alignment of lock chassis and strike plate. Ensure screws are tight.
La porta fa soroll quan es tanca.Strike plate not properly aligned or mortised.Adjust the strike plate position or depth to ensure a snug fit with the latch bolt.

Especificacions

CaracterísticaDetall
Número de model129002
SèrieSèrie 2500
Tipus de bloqueigCylindrical Passage Lock (Non-locking)
MaterialHeavy Gauge Steel, Zinc (Handle Material: Zinc)
AcabarCrom setinat
Estil de palancaWithnell
Enrere2-3/4 polzades (70 mm)
Door Prep - Cross Bore2-1/8 inches (54 mm) diameter
Door Prep - Latch Hole (Edge Bore)1 inch (25 mm) diameter
Orientació de la màSense mà
GrauGrade 2 (Standard Duty Commercial)
Placa de vagaVaga de l'ASA
Components inclosos2510 WTN US26D (Lock assembly, latch, strike, screws, 2 operating keys)

Informació de la garantia

Hager products are manufactured to high standards. For specific warranty terms and conditions applicable to the 2500 Series Cylindrical Passage Lock, please refer to the official Hager website or contact Hager customer support directly. Keep your purchase receipt as proof of purchase.

Atenció al client

If you require further assistance or have questions regarding your Hager 2500 Series Cylindrical Passage Lock, please contact Hager customer support:

  • Weblloc: Visit the official Hager weblloc web per a recursos de suport i informació de contacte.
  • Contacte: Refer to the packaging or Hager's website for phone numbers or email addresses.

When contacting support, please have your model number (129002) and purchase details available.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.