1. Introducció i finalview
This manual provides essential instructions for the safe and effective use of your BriskHeat Full-Coverage Drum Heater, Model FGDHC55120D. This industrial-grade heater is designed for 55-gallon drums, offering solutions for viscosity control, freeze protection, temperature maintenance, and heating contents to a desired temperature. Its robust construction, high wattage, and efficient insulation ensure reliable performance.

Image 1: BriskHeat Full-Coverage Drum Heater (Model FGDHC55120D) installed on a drum. This image illustrates the heater's full-coverage design and integrated control box.
2. Informació de seguretat
Read and understand all safety warnings and instructions before operating this drum heater. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Seguretat elèctrica: Assegureu-vos que la font d'alimentació coincideixi amb el volum de l'escalfadortage (120 Volts). Do not operate with damaged cords or plugs. Always connect to a grounded outlet.
- Materials inflamables: Do not use this heater with drums containing highly flammable liquids or in environments with explosive atmospheres unless specifically rated for such use. Consult material safety data sheets (MSDS) for contents.
- Sobreescalfament: Do not cover the heater's control unit or restrict airflow around the drum. Monitor the temperature to prevent overheating of drum contents.
- Col·locació: Ensure the drum and heater are placed on a stable, non-combustible surface. The heater is designed for floor mount applications.
- Manteniment: Desconnecteu l'alimentació abans de realitzar qualsevol manteniment o neteja.
3. Contingut del paquet
Verifiqueu que hi hagi tots els elements en desempaquetar:
- 1 x BriskHeat Full-Coverage Drum Heater (Model FGDHC55120D)
- Manual d'instruccions (aquest document)
4. Configuració i instal·lació
The BriskHeat Full-Coverage Drum Heater is designed for easy installation on standard 55-gallon drums.
- Prepara el tambor: Ensure the 55-gallon drum is clean, dry, and free from any sharp edges that could damage the heater's fabric.
- Posició de l'escalfador: Carefully wrap the heater around the drum, ensuring it covers the drum's circumference evenly. The heater is designed for floor mount applications, so ensure the drum is on a stable surface.
- Assegureu l'escalfador: Use the integrated fastening system (e.g., straps or buckles) to secure the heater snugly around the drum. Ensure there are no gaps or loose areas that could compromise heating efficiency.
- Connectar l'alimentació: Plug the heater's power cord into a grounded 120 Volt electrical outlet. Ensure the outlet can handle the heater's 1600 Watts power consumption.
5. Instruccions de funcionament
The BriskHeat drum heater features an integrated control system for temperature management.
- Encès: Once plugged in, the heater is ready for operation. The control unit will typically display the current temperature or be ready for programming.
- Temperatura establerta: Use the controls on the integrated unit to set the desired temperature for the drum contents. Refer to the specific instructions on the control unit for detailed programming steps.
- Monitor de funcionament: The heater will begin to warm the drum contents. Periodically monitor the temperature and the heater's operation to ensure it is functioning as expected.
- Apagar: To turn off the heater, either unplug it from the power source or use the power control on the integrated unit, if available.

Imatge 2: Primer pla view of the control box on the BriskHeat Full-Coverage Drum Heater. This box houses the temperature controls and power connection.
6. Manteniment
Proper maintenance ensures the longevity and safe operation of your drum heater.
- Neteja: Disconnect power before cleaning. Wipe the exterior of the heater with a damp cloth. Do not immerse the heater in water or use abrasive cleaners.
- Inspecció: Regularly inspect the heater for any signs of wear, tear, cuts, or damage to the fabric, power cord, or control unit. Do not operate a damaged heater.
- Emmagatzematge: When not in use, store the heater in a clean, dry place, away from direct sunlight and extreme temperatures. Ensure it is properly coiled or folded to prevent damage to internal heating elements.
7. Solució De Problemes
If you encounter issues with your BriskHeat drum heater, refer to the following common troubleshooting steps:
- L'escalfador no s'encén:
- Check if the power cord is securely plugged into a live 120V outlet.
- Verify that the circuit breaker or fuse for the outlet has not tripped.
- Inspeccioneu el cable d'alimentació per veure si hi ha danys visibles.
- Heater Not Reaching Desired Temperature:
- Ensure the temperature setting on the control unit is correct.
- Verify the heater is snugly fitted around the drum to minimize heat loss.
- Check for drafts or cold ambient temperatures that may affect heating efficiency.
- Ensure the drum contents are not excessively cold or require a longer heating time.
- Olors inusuals o fum: Immediately disconnect power and cease operation. Contact BriskHeat customer support.
8. Especificacions
| Atribut | Detall |
|---|---|
| Fabricant | Calor ràpida |
| Número de part | 2950106 |
| Pes de l'article | 25 lliures |
| Número de model de l'article | FGDHC55120D |
| Mida | Large (for 55-gallon drums) |
| Font d'alimentació | Elèctric amb cable |
| Voltage | 120 Volts |
| Wattage | 1600 watts |
| Quantitat de paquet d'articles | 1 |
| Tipus de muntatge | Muntatge al terra |
| ASIN | B00GE9LSO8 |
| Data de primera disponibilitat | 30 d'abril de 2015 |
9. Garantia i Suport
For warranty information, technical support, or service inquiries, please contact BriskHeat directly. Keep your purchase receipt and model number (FGDHC55120D) handy when contacting support.
BriskHeat Contact Information:
Please refer to the official BriskHeat weblloc web o l'embalatge del producte per obtenir les dades de contacte més actualitzades.