1. Introducció

The Phottix Indra500 TTL Studio Light (PH00300) is a versatile and portable monolight designed for professional photographers. It combines the power of a studio flash with the flexibility of battery operation and TTL capabilities for both Nikon and Canon camera systems. This manual provides essential information for the safe and effective use of your Indra500 TTL Studio Light.

2. Informació de seguretat

Please read and understand all safety instructions before using the Phottix Indra500 TTL Studio Light. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • No exposeu la unitat a la pluja, la humitat o les temperatures extremes.
  • No intenteu desmuntar ni modificar la unitat. Encarregueu tot el manteniment a personal qualificat.
  • Ensure the unit is securely mounted on a stable light stand before operation.
  • Mantingueu la unitat allunyada de materials inflamables.
  • Feu servir només la bateria i el carregador especificats.
  • Avoid direct eye exposure to the flash tube.
  • Unplug the unit from power sources when not in use or during cleaning.

3. Contingut del paquet

Verifiqueu que tots els elements que s'enumeren a continuació s'inclouen al vostre paquet:

  • Phottix Indra 500 TTL Studio Light
  • Bateria de polímer Li-ion
  • Carregador de bateria
  • Phottix Studio Light Reflector 7"
  • Straight Studio Light Power Cable 3.5m
  • Bossa
  • User manual (digital format, typically on USB or downloadable)

4. Característiques del producte

The Phottix Indra500 TTL Studio Light offers a range of advanced features:

  • 500Ws Monolight: Provides powerful illumination for studio and on-location photography.
  • TTL, Manual, and Stroboscopic Modes: Versatile flash modes for various shooting scenarios.
  • 1/8,000 Sec. Shutter Speed Possible: Enables high-speed sync (HSS) for freezing action and controlling ambient light.
  • Power Variable from 1/128 to Full: Precise power control over an 8-stop range.
  • Built-in Odin Receivers for Nikon & Canon: Seamless integration with Phottix Odin TTL triggers for remote control.
  • Built-in Phottix Strato II Receiver: Compatibility with Phottix Strato II triggers for manual flash control.
  • LED Modeling Light: Proporciona llum contínua per a la pre-viewefectes d'il·luminació.
  • Adaptador de CA opcional: Allows for continuous power when battery operation is not required.

5. Identificació de components

Familiarize yourself with the various parts of your Phottix Indra500 TTL Studio Light.

Phottix Indra500 TTL Studio Light with 7-inch reflector attached, angled view.

Figure 5.1: Front Angled View with Reflector. This image displays the Phottix Indra500 TTL Studio Light from an angled front perspective, showcasing the main body, the attached 7-inch reflector, and the mounting bracket. The reflector is silver on the inside, designed to shape and direct the light output. The light stand mount is visible at the bottom, allowing for attachment to standard light stands.

lateral view of Phottix Indra500 TTL Studio Light showing power input and handle.

Figura 5.2: lateral View with Power Connection. Això view highlights the side of the Indra500 unit. The green "INDRA500 TTL powered by Phottix Odin" label is prominent. On the left side, a robust power input port with a screw-lock mechanism is visible, where the battery pack or optional AC adapter connects. A handle for carrying or adjusting the light is also shown at the top rear.

En angle view of Phottix Indra500 TTL Studio Light showing control panel and display.

Figura 5.3: Angle View of Control Panel. This image provides a closer look at the control panel area. The LCD screen displays settings such as power level (e.g., 1/128), channel (CH:1), and group (GR: A). Below the screen are several buttons, including "READY" (red), a green button, a power button, and "MODEL" for the modeling light. The mounting bracket and adjustment knob are also visible.

posterior view of Phottix Indra500 TTL Studio Light focusing on the LCD display and control buttons.

Figura 5.4: posterior View of Display and Controls. This detailed rear view focuses on the main LCD display and the primary control buttons. The screen clearly shows "Odin-C", power output (1/128), battery indicator, channel, group, and menu options. The "READY" indicator, power button, and modeling light button are prominent, along with a rotary dial for adjusting settings. The connection port for the power cable is also visible on the lower right.

6. Configuració

6.1 Fixació del reflector

  1. Align the three bayonet mounts on the 7-inch reflector with the corresponding slots on the front of the Indra500 unit.
  2. Introduïu el reflector i gireu-lo en sentit horari fins que quedi ben encaixat.
  3. To remove, press the release button (if present) and twist counter-clockwise.

6.2 Muntatge en un suport de llum

  1. Loosen the adjustment knob on the light stand mount of the Indra500.
  2. Place the unit onto a standard light stand stud.
  3. Tighten the adjustment knob to secure the unit.
  4. Ajusteu l'angle d'inclinació de la llum segons calgui i estrenyeu el botó de bloqueig de la inclinació.

6.3 Instal·lació i càrrega de la bateria

  1. Ensure the Indra500 is powered off.
  2. Connect the Li-ion polymer battery pack to the power input port on the side of the Indra500. Secure the connection by twisting the locking ring.
  3. To charge the battery, connect the battery charger to the battery pack and plug the charger into a suitable power outlet. The charging indicator on the charger will show the charging status.
  4. A full charge typically takes approximately 5 hours and provides around 400 full-power flashes.

6.4 Connecting AC Power (Optional)

If using the optional AC adapter for continuous power:

  1. Ensure the Indra500 is powered off.
  2. Connect the optional AC adapter to the power input port on the side of the Indra500. Secure the connection.
  3. Plug the AC adapter into a suitable wall outlet (110-220 VAC).

7. Funcionament

7.1 Engegada/apagada

  • Press and hold the power button (typically marked with a circle and a vertical line) on the control panel to turn the unit on or off.
  • La pantalla LCD s'il·luminarà en encendre'l.

7.2 Selecció del mode

The Indra500 supports TTL, Manual (M), and Stroboscopic (Multi) modes. Use the "Mode" button on the control panel to cycle through these options.

  • Mode TTL: The flash output is automatically adjusted based on the camera's metering system. Power can be adjusted remotely +/- 3 EV using an optional Odin transmitter.
  • Mode manual (M): Flash output is set manually from 1/128 to full power. Use the rotary dial to adjust the power level.
  • Stroboscopic Mode (Multi): The flash fires multiple times during a single exposure. Consult the full user manual for detailed settings for frequency and number of flashes.

7.3 Ajust de potència

In Manual mode, rotate the main dial on the control panel to increase or decrease the flash power. The power level will be displayed on the LCD screen.

7.4 Using Built-in Receivers (Odin/Strato II)

The Indra500 has built-in receivers for Phottix Odin (Nikon/Canon) and Strato II triggers. To use remote control:

  1. Ensure your Phottix Odin or Strato II transmitter is set to the same channel and group as the Indra500.
  2. Refer to your transmitter's manual for specific instructions on pairing and remote control functions.
  3. The Indra500 supports high-speed sync (HSS) up to 1/8000s when used with compatible Odin TTL transmitters.

7.5 Llum de modelatge

Press the "MODEL" button on the control panel to turn the LED modeling light on or off. The modeling light helps visualize the lighting effect before firing the flash.

8. Manteniment

8.1 Neteja

  • Ensure the unit is powered off and disconnected from all power sources before cleaning.
  • Utilitzeu un drap suau i sec per netejar l'exterior de la unitat.
  • Per a la brutícia persistent, una mica deamp cloth with a mild detergent can be used, followed by a dry cloth.
  • No utilitzeu netejadors abrasius, dissolvents ni productes químics forts.
  • Clean the flash tube and modeling lamp with a lint-free cloth.

8.2 Emmagatzematge

  • Store the Indra500 in a cool, dry place, away from direct sunlight and extreme temperatures.
  • If storing for an extended period, remove the battery pack and store it separately.
  • Periodically charge the battery (every 3-6 months) to maintain its health.

9. Solució De Problemes

If you encounter issues with your Indra500, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
La unitat no s'encén.Battery depleted or not connected properly. AC adapter not connected/faulty.Charge the battery or ensure it is securely connected. Check AC adapter connection and power source.
El flaix no es dispara.Trigger not paired, incorrect channel/group, low battery, flash in sleep mode, camera settings.Verify trigger settings (channel, group). Check battery level. Wake unit from sleep mode. Ensure camera flash settings are correct (e.g., external flash enabled).
Sortida de flaix inconsistent.Low battery, flash tube nearing end of life, environmental factors.Ensure battery is fully charged. If issue persists, contact support for flash tube replacement.
High-Speed Sync (HSS) not working.Incompatible trigger, camera settings, firmware issue.Ensure you are using a compatible Phottix Odin TTL transmitter. Check camera flash settings for HSS. Verify firmware is up to date (refer to Phottix weblloc).

If the problem persists after attempting these solutions, please contact Phottix customer support.

10. Especificacions

Key technical specifications for the Phottix Indra500 TTL Studio Light (PH00300):

CaracterísticaDetall
Número de modelPH00300
Sortida de flaix500 Ws
Potència1/128 to Full Power (8-stop range)
Recycling Time (Battery)0.1 a 2 segons
Flash Duration (t.1)As short as 1/15,000 sec (at reduced power)
Velocitat de sincronització del flaixUp to 1/8000 sec (HSS)
Built-in ReceiversPhottix Odin (Nikon & Canon), Phottix Strato II
Modelatge de llumLED
Tipus de bateriaPolímer d'ions de liti
Flaixos per càrregaApprox. 400 at full power
Temps de càrrega de la bateriaAprox. 5 hores
Entrada de potènciaBattery or Optional 110-220 VAC Adapter
Dimensions26.7 x 19 x 14 cm
Pes2.1 kg
Muntatges compatiblesCanon (and Nikon via Odin receivers)

11. Informació de la garantia

Phottix products are typically covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and retailer. Please retain your proof of purchase for warranty claims.

For detailed warranty information, please refer to the warranty card included with your product or visit the official Phottix weblloc.

12. Atenció al client

For technical assistance, troubleshooting, or service inquiries, please contact Phottix customer support.

  • Assistència en línia: Visit the official Phottix website for FAQs, firmware updates, and support contact forms.
  • Suport per correu electrònic: Refer to the Phottix website for regional email contact information.
  • Suport telefònic: Check the Phottix weblloc web per a números de telèfon regionals.

When contacting support, please have your product model (PH00300) and serial number ready.