ARDO Calypso-To-Go

Ardo Calypso-to-Go Double Electric Breast Pump User Manual

Model: Calypso-To-Go

Introducció

This manual provides comprehensive instructions for the safe and effective use of your ARDO Calypso-to-Go Double Electric Breast Pump. Please read this manual thoroughly before first use and retain it for future reference.

Ardo Calypso-to-Go Double Electric Breast Pump with accessories and carrying bag

Image: The Ardo Calypso-to-Go Double Electric Breast Pump, showing the main unit, bottles, breast shells, and the included messenger bag.

Què s'inclou

The Calypso-to-Go package includes the following components:

  • 1x Calypso Breastpump unit
  • 2x Pumpsets with 150ml bottles and 26mm Breastshells
  • 2x Lids with removable insert
  • 2x 31mm Breastshells
  • 2x 28mm Breastshells (fits in 31mm breastshell)
  • 2x Optiflow inserts (fits in 31mm breastshell)
  • 2x Extra lip valves
  • 1x Brush for cleaning
  • 1x Bottle Holder
  • 1x adaptador de xarxa
  • 1x Instruction manual and quick guide
  • 8x Bottles (total, including those with pumpsets)
  • 1x Messenger bag
  • 1x Cool bag
  • 3x Ice packs
  • 1x Amaryll hand pump
All components of the Ardo Calypso-to-Go breast pump kit laid out

Imatge: Una imatge detallada view of all items included in the Ardo Calypso-to-Go kit, such as the pump unit, various breast shell sizes, bottles, cleaning brush, power adapter, and the travel bag with cooling elements.

Muntatge i muntatge

  1. Components nets: Before first use, disassemble and clean all parts that come into contact with breast milk according to the "Maintenance and Cleaning" section.
  2. Assemble Pumpset:
    • Attach the chosen breast shell (26mm, 28mm, or 31mm) to the connector.
    • Insert the Optiflow soft massage insert (if desired) into the breast shell.
    • Attach the lip valve to the valve head.
    • Screw the bottle onto the pumpset.
    • Connect the tubing to the pumpset and the pump unit.
  3. Opcions d'energia: The Calypso-to-Go offers three power options:
    • Adaptador de xarxa: Connect the power adapter to the pump unit and a wall outlet.
    • Piles AA: Introduïu 6 piles AA al compartiment de piles.
    • Optional Car Adapter: (Not included in standard package) Connect a compatible car adapter for use in a vehicle.
  4. Col·locació: Place the pump unit on a stable, flat surface. Ensure the tubing is not kinked.
Disassembled breast pump components including breast shells, bottles, and tubing

Image: Various components of the breast pump, including different sized breast shells, bottles, and the main pump unit, ready for assembly.

Instruccions de funcionament

The ARDO Calypso-to-Go breast pump features 64 individual settings for vacuum and cycle to ensure a comfortable and efficient pumping experience.

  1. Encès: Premeu el botó d'engegada () to turn on the pump. The display will illuminate.
  2. Adjust Vacuum (Suction Strength): Use the "Vacuum" up () i cap avall () buttons to increase or decrease the suction strength. Start with a low setting and gradually increase to a comfortable level.
  3. Adjust Cycles (Frequency): Use the "Cycles" up () i cap avall () buttons to adjust the pumping frequency. Higher cycles are often used for let-down, while lower cycles are for milk expression.
  4. Find Your Ideal Setting: Experiment with different combinations of vacuum and cycle settings to find what works best for your body. The goal is effective milk expression without discomfort.
  5. Shabbat Mode: The Calypso is Shabbat-mode capable with an external Shabbat clock (not included). Refer to the specific instructions for using this feature if applicable.
  6. Apagar: Manteniu premut el botó d'encesa () to turn off the pump.
Close-up of the Ardo Calypso breast pump control panel with vacuum and cycle buttons

Image: A close-up of the Calypso breast pump's control panel, highlighting the display and the "Vacuum" and "Cycles" adjustment buttons.

The pump's Vacuum Seal Technology ensures a closed system, preventing breast milk or impurities from entering the connecting tube or pump unit. This design provides reliable protection against contamination and infection.

Manteniment i Neteja

Una neteja i un manteniment adequats són crucials per a la higiene i la longevitat del teu extractor de llet.

  1. Desmuntatge: After each use, disassemble all parts of the pumpset that come into contact with breast milk (breast shells, Optiflow inserts, valve heads, lip valves, bottles).
  2. Neteja:
    • Rinse all disassembled parts with cold water immediately after use.
    • Wash parts in warm, soapy water using the provided cleaning brush.
    • Esbandiu bé amb aigua neta.
    • Air dry on a clean surface or use a dedicated drying rack.
  3. Esterilització: Sterilize parts regularly (e.g., daily) by boiling for 5 minutes, using a steam sterilizer, or a dishwasher (top rack, if dishwasher safe).
  4. Unitat de bomba: The pump unit and tubing do not come into contact with breast milk due to the closed system. Wipe the exterior of the pump unit with a damp cloth as needed. Do not immerse the pump unit in water.
  5. Emmagatzematge: Store clean and dry components in a clean, dry place when not in use.

Resolució de problemes

If you encounter issues with your ARDO Calypso-to-Go breast pump, please refer to the following common solutions:

  • Sense succió o succió feble:
    • Check that all pumpset components are correctly assembled and securely fitted.
    • Ensure the lip valve is clean, undamaged, and properly seated.
    • Verify that the tubing is securely connected to both the pumpset and the pump unit, and is not kinked or damaged.
    • If using batteries, check if they are correctly inserted and have sufficient charge. Replace if necessary.
  • La bomba no s'encén:
    • Ensure the mains adapter is securely plugged into both the pump and a working power outlet.
    • If using batteries, check if they are correctly inserted and have sufficient charge. Replace if necessary.
  • Discomfort During Pumping:
    • Adjust the vacuum (suction strength) to a lower, more comfortable level.
    • Ensure you are using the correct breast shell size. Refer to the sizing guide in your quick start manual or consult a lactation professional.
    • Ensure proper breast positioning within the breast shell.
  • Low Milk Output:
    • Ensure you are using the correct breast shell size.
    • Experiment with different vacuum and cycle settings to find the most effective combination for you.
    • Ensure you are relaxed and comfortable during pumping. Stress can affect milk flow.
    • Consult a lactation professional if low milk output persists.

If these steps do not resolve the issue, please contact ARDO customer support.

Especificacions

Número de modelCalypso-To-Go
Dimensions del producte12 x 10 x 12 polzades
Pes1 Pound (pump unit)
Opcions d'energiaMains adapter, 6 AA batteries (required), Optional car adapter
MaterialBPA Free components
Tipus de sistemaClosed System (Vacuum Seal Technology)
Configuració64 adjustable vacuum and cycle settings
FabricantArdo medical, Inc.

Garantia i Suport

The ARDO Calypso-to-Go breast pump is designed for durability and reliability. ARDO medical, Inc. offers a warranty for this product.

  • Període de garantia: The pump unit is covered by a warranty of 400 hours of use or 1 year, whichever is longer.
  • Política de devolució: Products may be eligible for a refund or replacement within 90 days of purchase, subject to retailer's terms.
  • Avís legal: Les declaracions sobre suplements dietètics no han estat avaluades per la FDA i no tenen la intenció de diagnosticar, tractar, curar o prevenir cap malaltia o afecció de salut.

For further assistance, product registration, or to inquire about specific warranty details, please contact Ardo medical, Inc. directly or visit their official store:

Visit the ARDO Store on Amazon

© 2023 Ardo medical, Inc. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.