Introducció
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Idec RH2B-UL-AC110-120V Electromechanical Relay. Please read this manual thoroughly before using the product to ensure proper function and to prevent potential hazards.
Informació de seguretat
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working with the relay.
- Always ensure power is disconnected before installation, wiring, or maintenance.
- Comproveu el vol correctetage and current ratings before connecting the relay to a circuit.
- Do not operate the relay in environments exceeding its specified temperature or humidity limits.
- Assegureu-vos d'una connexió a terra adequada si escau.
Producte acabatview
The Idec RH2B-UL-AC110-120V is a general-purpose electromechanical relay designed for various industrial control applications. It features a compact design and is suitable for DIN rail mounting.

Figure 1: Idec RH2B-UL-AC110-120V Relays in their original packaging, showing a pack of four units.

Figure 2: A single Idec RH2B-UL-AC110-120V relay, providing an angled view of the transparent casing i components interns.
Configuració i instal·lació
Follow these steps for proper installation of the Idec RH2B-UL-AC110-120V Relay:
- Desconnexió d'alimentació: Ensure all power to the circuit is completely disconnected before beginning installation.
- Muntatge: The relay is designed for DIN Rail mounting. Securely attach the relay to a standard DIN rail in your control panel.
- Cablejat: The relay utilizes through-hole connectors. Carefully connect the control circuit wiring to the coil terminals and the load circuit wiring to the contact terminals. Refer to the wiring diagram (if available in your system documentation) for specific terminal assignments.

Figura 3: A baix view of the relay, showing the through-hole connector pins for wiring connections.
- Voltage Verificació: Confirmeu que el volum de subministramenttage for the coil matches the relay's specified voltage de 110-120V AC, 50/60Hz.

Figura 4: Primer pla view of the relay's transparent casing, highlighting the model number and voltage specifications (AC110-120V, 50/60Hz).
- Load Verification: Ensure the connected load does not exceed the relay's contact ratings (e.g., 10A resistive at 240VAC).

Figura 5: lateral view of the relay, displaying detailed electrical ratings and certifications.
- Comprovació final: Before restoring power, double-check all connections for security and correctness.
Instruccions de funcionament
The Idec RH2B-UL-AC110-120V Relay operates automatically based on the control signal applied to its coil. When the specified AC voltage (110-120V) is applied to the coil, the relay contacts will switch, opening or closing the connected load circuit. When the voltage is removed, the contacts return to their original state.
- Ensure the control signal is within the specified voltage range for reliable operation.
- Observe any indicator lights on the relay (if present) to confirm coil energization.
Manteniment
The Idec RH2B-UL-AC110-120V Relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:
- Inspecció visual: Reviseu periòdicament el relé per detectar qualsevol signe de danys físics, decoloració o connexions soltes.
- Neteja: Si cal, netegeu suaument l'exterior del relé amb un drap sec i suau. No utilitzeu dissolvents ni netejadors abrasius.
- Inspecció de contactes: In critical applications, inspect contacts for pitting or wear. Replace the relay if significant wear is observed.
- Condicions ambientals: Assegureu-vos que l'entorn operatiu es mantingui dins dels rangs de temperatura i humitat especificats per evitar fallades prematures.
Resolució de problemes
Si el relé no funciona com s'espera, tingueu en compte els següents problemes comuns:
| Problema | Causa possible | Solució |
|---|---|---|
| Relay coil does not energize. | No power to coil, incorrect voltage, faulty wiring, or damaged coil. | Check power supply, verify voltage (110-120V AC), inspect wiring connections, test coil continuity. |
| Contacts do not switch. | Coil not energizing, contacts welded, or mechanical failure. | Refer to "Relay coil does not energize" solutions. If coil is good, replace relay. |
| Load not receiving power. | Relay contacts not closing, open circuit in load wiring, or faulty load. | Verify relay operation. Check load circuit wiring and the load itself. |
If troubleshooting steps do not resolve the issue, contact Idec technical support or a qualified electrician.
Especificacions
| Paràmetre | Valor |
|---|---|
| Número de model | RH2B-UL-AC110-120V |
| Marca | Idec |
| Bobina Voltage | 110-120V AC |
| Freqüència | 50/60 Hz |
| Current Rating (Resistive) | 10A @ 240VAC, 10A @ 30VDC |
| Current Rating (General Use) | 7.5A @ 120VAC, 7A @ 240VAC, 7.5A @ 30VDC |
| Valoració de la potència | 1/6 HP @ 120VAC, 1/3 HP @ 240VAC |
| Tipus de muntatge | Muntatge sobre carril DIN |
| Tipus de connector | Forat a través |
| Mode d'operació | Automàtic |
| Pes de l'article | 0.01 unces |
| Fabricant | Idec |
Garantia i Suport
For warranty information and technical support, please contact Idec directly through their official weblloc web o canals d'atenció al client. Conserveu el rebut de compra per a reclamacions de garantia.
Idec Official Weblloc: us.idec.com