Graphtec GL240

Graphtec America GL240 Data Logger Instruction Manual

Model: GL240

1. Producte acabatview

The Graphtec America GL240 is a versatile 10-channel data logger designed for precise measurement and recording of various data types. It features a 4.3-inch wide TFT color LCD screen for clear data visualization and intuitive operation. The device includes 4GB of internal flash memory and supports SDHC cards up to 32GB for extended storage. Its robust design ensures high isolation per channel, making it suitable for diverse industrial and scientific applications.

Graphtec GL240 Data Logger with annotated features

Image 1: Graphtec GL240 Data Logger highlighting key features such as isolated channels, logic/pulse signal input port, SDHC memory slot, and the 4.3-inch wide TFT color LCD screen.

Característiques principals:

  • 4.3-inch wide TFT color LCD screen for real-time data display.
  • 10 isolated input channels for diverse measurement applications.
  • Multiple power source options: AC adapter, optional DC (B-514), and optional rechargeable battery pack (B-569).
  • Extended memory capacity with 4GB internal flash and SDHC card support up to 32GB.
  • Alta velocitat sampling interval up to 10ms for a single channel and 100ms for all 10 channels.
  • 16-bit resolution for accurate data acquisition.
  • High isolation per channel (125 VAC RMS and 350 VDC channel-to-chassis).
  • Up to 110Vp-p input range between positive and negative terminals.
  • Four alarm output ports for monitoring critical thresholds.

2. Configuració

This section outlines the basic steps for setting up your GL240 Data Logger. For detailed instructions, please refer to the included StartUp Manual and Application CD.

2.1 Desembalatge i inspecció

  1. Carefully remove the GL240 unit and all accessories from the packaging.
  2. Verify that all components listed in the packing list are present. These typically include the GL240 device, rubber grommet, Application CD, and AC/DC power supply.
  3. Inspect the unit for any signs of damage during transit. If damage is found, contact your supplier immediately.

2.2 Connexió d'alimentació

  1. Connect the provided AC/DC power supply to the GL240's power input port.
  2. Plug the AC adapter into a suitable power outlet.
  3. Alternatively, if using the optional rechargeable battery pack (B-569) or DC power (B-514), ensure they are correctly installed and charged according to their respective manuals.

2.3 Instal·lació de la targeta SD

  1. Locate the SD card slot on the GL240 unit.
  2. Insert a compatible SDHC card (up to 32GB) into the slot until it clicks into place. Ensure the card is inserted in the correct orientation.
  3. It is recommended to format the SD card using the GL240's menu system before first use to ensure compatibility and optimal performance.

2.4 Instal·lació del programari

  1. Insert the Application CD into your computer's CD/DVD drive.
  2. Follow the on-screen instructions to install the necessary software for data analysis and device configuration.
  3. Refer to the software's user manual for detailed installation and usage instructions.
Davant view of Graphtec GL240 Data Logger showing input terminals

Imatge 2: Frontal view of the Graphtec GL240 Data Logger, illustrating the 10 input terminals and the control panel.

3. Instruccions de funcionament

Aquesta secció ofereix una descripció generalview of operating the GL240 Data Logger. For detailed operational procedures, refer to the comprehensive user manual provided on the Application CD.

3.1 Engegada/apagada

  • Per engegar: premeu i manteniu premut el botó PODER botó fins que la pantalla s'il·lumini.
  • Per apagar: premeu i manteniu premut el botó PODER botó fins que la unitat s'apaga.

3.2 Navegació per la interfície d'usuari

The GL240 features a 4.3-inch color LCD and a control panel with directional keys and dedicated function buttons.

  • Use the directional keys (UP, ABAIX, ESQUERRA, DRET) to navigate through menus and settings.
  • Premeu el botó ENTRAR botó per confirmar les seleccions.
  • El MENÚ button accesses the main settings and configuration options.
  • El VISUALITZACIÓ button cycles through different display modes (e.g., waveform, numerical).

3.3 Configuring Channels and Settings

  1. Accedeix al MENÚ to configure individual channels.
  2. Set input types, measurement ranges, and scaling for each of the 10 channels.
  3. Configurar sampling intervals (e.g., 10ms for single channel, 100ms for all channels).
  4. Set alarm thresholds for the four alarm output ports if required.

3.4 Starting and Stopping Data Logging

  • After configuring settings, press the INICI/PARA button to begin data logging. The status indicator will change to show recording is active.
  • Per aturar el registre, premeu la tecla INICI/PARA botó de nou.
  • Logged data is saved to the internal 4GB flash memory or the inserted SD card.

3.5 Data Review and Export

  • On the GL240, use the REVIEW button to access recorded data directly on the device's display.
  • To perform detailed analysis and export data, transfer the recorded files from the SD card to a computer.
  • Use the Graphtec software installed from the Application CD to read, analyze, and export the data into formats such as CSV for use with other applications like Microsoft Excel.
Graphtec GL240 Data Logger held in hands

Image 3: The Graphtec GL240 Data Logger held in hands, demonstrating its compact size and portability.

4. Manteniment

Proper maintenance ensures the longevity and reliable performance of your GL240 Data Logger.

4.1 Neteja

  • Netegeu l'exterior de la unitat amb un drap suau i sec.
  • Per a la brutícia persistent, lleugerament dampal drap amb aigua o un netejador suau i no abrasiu.
  • Do not use strong solvents, alcohol, or abrasive cleaning agents, as these can damage the casing o pantalla.
  • Ensure no liquids enter the device through ports or openings.

4.2 Gestió de targetes SD

  • Regularly back up important data from the SD card to a computer.
  • Periodically format the SD card using the GL240's menu to maintain optimal performance and prevent data corruption. Ensure all necessary data is backed up before formatting.
  • Use only high-quality, compatible SDHC cards.

4.3 Battery Care (if applicable)

  • If using the optional rechargeable battery pack (B-569), follow the charging instructions provided with the battery.
  • Eviteu descarregar completament la bateria amb freqüència per allargar-ne la vida útil.
  • Store the unit and battery in a cool, dry place when not in use for extended periods.

5. Solució De Problemes

This section addresses common issues you might encounter with the GL240 Data Logger. For more complex problems, consult the full user manual or contact Graphtec America technical support.

5.1 El dispositiu no s'encén

  • Comproveu la font d'alimentació: Ensure the AC adapter is securely connected to both the GL240 and a working power outlet.
  • Comprovació de la bateria: If using a battery pack, ensure it is charged and correctly installed.
  • Botó d'encesa: Confirm the POWER button is pressed and held sufficiently.

5.2 Data Not Recording

  • Targeta SD: Verify that an SD card is inserted correctly and has sufficient free space. Try reformatting the SD card (after backing up data).
  • Botó d'inici / aturada: Assegureu-vos el INICI/PARA button was pressed to initiate recording.
  • Configuració: Check channel settings and sampling intervals in the MENU to ensure they are correctly configured.

5.3 Data Cannot Be Read on Computer

  • Instal·lació de programari: Confirm that the Graphtec analysis software from the Application CD is correctly installed on your computer.
  • File Transferència: Ensure the data files are correctly transferred from the SD card to your computer.
  • Compatibilitat: Remember that GL240 data files require the dedicated Graphtec software for initial reading and export to common formats like CSV.

6. Especificacions

The following table details the technical specifications of the Graphtec GL240 Data Logger.

CaracterísticaEspecificació
Número de modelGL240
Mostra4.3-inch wide TFT color LCD screen
Canals10 canals
Memòria interna4GB Internal Flash memory
Memòria externaSD card slot (max 32GB SDHC compatible)
Resolució16 bits
Aïllament del canal125 VAC RMS and 350 VDC channel-to-chassis
Entrada Voltage RangUp to 110Vp-p between (+) and (-)
Max Sampling Interval10ms/1 channel, 100ms for all 10 channels
Alarm Output PortsFins a 4 canals
Fonts d'alimentacióAC, DC (B-514)*, rechargeable battery pack (B-569)*
Dimensions del producte7.6 x 4.6 x 1.6 polzades
Pes de l'article3 lliures
FabricantGraphtec America Inc
ASINB018TQUDTO
Data de primera disponibilitat2 de desembre de 2015

*Optional accessories, sold separately.

7. Garantia i Suport

For information regarding product warranty, please refer to the warranty card included with your GL240 Data Logger or visit the official Graphtec America website. Technical support and additional resources can be found through Graphtec America Inc.

  • Fabricant: Graphtec America Inc
  • Weblloc: Refer to product packaging or included documentation for official support channels.

© 2023 Graphtec America Inc. All rights reserved. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.