SIMPLEX 4099-9005

Simplex 4099-9005 Addressable Manual Pull Station (Dual Action) User Manual

Model: 4099-9005

1. Introducció

The Simplex 4099-9005 is an addressable manual pull station designed for use with compatible Simplex fire alarm control panels. This dual-action device requires two distinct operations to activate, reducing the likelihood of accidental activation. It is an integral component of a comprehensive fire detection and alarm system, providing a manual means for occupants to initiate an alarm in the event of a fire or other emergency.

2. Informació de seguretat

Instruccions importants de seguretat:

3. Producte acabatview

The Simplex 4099-9005 is a red, dual-action manual pull station. Its addressable nature allows the fire alarm control panel to identify the exact location of the activated station. The dual-action design requires a two-step process for activation: first, pushing in a bar, and then pulling down a handle.

Davant view of the Simplex 4099-9005 Addressable Manual Pull Station, showing the 'FIRE ALARM' label, 'PUSH BAR', and 'PULL HANDLE'.

Figura 1: Frontal view of the Simplex 4099-9005 Addressable Manual Pull Station. This image displays the primary components including the 'FIRE ALARM' text, the 'PUSH BAR' mechanism, and the 'PULL HANDLE' for activation.

4. Instal·lació

Proper installation is crucial for the reliable operation of the manual pull station.

4.1 Muntatge

4.2 Cablejat

4.3 Configuració de l'adreça

The 4099-9005 is an addressable device. Before connecting to the SLC, set the unique address for the pull station using the appropriate Simplex programming tool or DIP switches, as specified in the device's technical documentation. Each device on the SLC must have a unique address.

lateral view of the Simplex 4099-9005 Addressable Manual Pull Station, showing its depth and mounting points.

Figura 2: lateral view of the Simplex 4099-9005 Addressable Manual Pull Station. This image illustrates the depth of the unit and provides a perspective on its mounting configuration.

5. Funcionament

5.1 Activating the Alarm

In the event of a fire or emergency, follow these steps to activate the manual pull station:

  1. Empènyer cap a dins: Firmly push the bar labeled "PUSH BAR" on the front of the station.
  2. Tira cap avall: Once the bar is pushed in, pull down the handle labeled "PULL HANDLE" until it latches in the down position.

Activation will send an alarm signal to the fire alarm control panel, initiating the building's alarm sequence.

5.2 Resetting the Pull Station

After an alarm has been activated and the emergency resolved, the pull station must be reset. The Simplex 4099-9005 requires a B-Key for resetting.

  1. Insert B-Key: Locate the keyhole on the front of the pull station. Insert the B-Key into the keyhole.
  2. Clau en mà: Turn the B-Key clockwise or counter-clockwise (depending on the specific mechanism) to release the latched handle.
  3. Tancar la coberta: Return the handle to its original, unactivated position and close the front cover.
  4. Remove B-Key: Remove the B-Key.

The B-Key is considered a tool for maintenance and resetting, not a consumable item. If additional B-Keys are required, they can be ordered using PID: 252-019.

6. Manteniment

Regular maintenance ensures the continued reliability of your Simplex 4099-9005 pull station.

7. Solució De Problemes

If you encounter issues with your Simplex 4099-9005 pull station, consider the following:

For persistent issues, contact a qualified fire alarm technician.

8. Especificacions

CaracterísticaEspecificació
MarcaSIMPLEX
Número de model4099-9005
EstilSeguretat
Font d'alimentacióManual
Pes de l'article3.53 unces (100 grams)
Tipus d’alarmaAudible (via FACP)
MaterialGlass (referring to break-glass type, though this model is dual-action)
Dimensions del producte1 x 3.4 x 5 polzades
UPC643485652991
Número de partS4099-9005
Piles necessàriesNo

9. Informació de la garantia

Specific warranty details for the Simplex 4099-9005 Addressable Manual Pull Station are typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Simplex documentation or contact their customer service.

10. Atenció al client

For technical assistance, installation queries, or service requests, please contact your authorized Simplex dealer or a certified fire alarm technician. Ensure you have the product model number (4099-9005) and any relevant system information available when seeking support.

Documents relacionats - 4099-9005

Preview Centrals d'alarma d'incendis manuals direccionables Simplex IDNet/MAPNET II: dades del producte
Informació detallada sobre les estacions d'alarma d'incendis manuals direccionables Simplex sèrie 4099, compatibles amb els sistemes IDNet i MAPNET II. Característiques, especificacions, opcions de muntatge i selecció de productes per a diversos models, incloent-hi opcions d'acció simple, doble acció (trencavidres i empenta) i SENSE AGARRE. Compleix amb els requisits de l'ADA i està homologat per UL, ULC, FM i CSFM.
Preview Estacions manuals direccionables simplex: perifèrics IDNet/MAPNET II
Exploreu les estacions d'alarma d'incendis manuals direccionables Simplex, detallant les seves característiques, tipus d'acció simple/doble, opcions NO GRIP i compatibilitat amb els sistemes IDNet/MAPNET II. Inclou informació de muntatge i especificacions.
Preview Simplex 2099 Series Single and Double Action Manual Fire Alarm Stations Datasheet
Datasheet for Simplex 2099 Series non-coded, non-addressable manual fire alarm pull stations. Covers features, operation types, application references, product selection, mounting options, and specifications.
Preview Simplex 4010ES: Sistemes de comandament d'extinció automàtica per a gicleurs
Tècnica de guia Simplex 4010ES detallant els mòduls de comandament per als sistemes d'extinció automàtics per gicleurs, couvrant els modes déluge et préventif, amb especificacions, homologacions i esquemes de câblage.
Preview Simplex 4099-9801C IDNet™ 2-Stage Station IAM Installation Instructions
Installation instructions for the Simplex 4099-9801C IDNet™ 2-Stage Station Individual Addressable Module (IAM). Covers mechanical installation, electrical connections, and address configuration for fire alarm systems.
Preview Simplex 4004 Fire Alarm Control Panel: Installation and Operation Instructions
Comprehensive guide for installing, operating, and programming the Simplex 4004 Fire Alarm Control Panel (FACP), including system overview, requirements, wiring, module descriptions, and troubleshooting.