1. Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of your Claber 90814 24V Solenoid Valve. This robust and reliable solenoid valve is designed for underground irrigation systems, ensuring efficient water management. It is engineered to operate effectively across a wide range of water pressures, from minimal to high, and is compatible with all Claber 24V programmers.

Image 1: Claber 90814 24V Solenoid Valve. This image shows the compact design of the valve, highlighting its inlet and outlet connections and the solenoid component.
2. Informació de seguretat
- Always disconnect power to the irrigation controller before installing or servicing the solenoid valve.
- Ensure all electrical connections are waterproof and comply with local electrical codes.
- Do not exceed the maximum operating pressure of 12 bar (174 psi).
- Install the valve in a location protected from freezing temperatures.
- Use appropriate tools for installation to avoid damaging the valve or piping.
3. Contingut del paquet
Verifiqueu que tots els components siguin presents abans de començar la instal·lació:
- 1 x Claber 90814 24V Solenoid Valve
4. Configuració i instal·lació
- Preparar la ubicació: Choose a suitable location for the valve, typically within a valve box, ensuring it is accessible for maintenance and protected from direct sunlight or extreme weather.
- Connectar canonades: The valve features 1" female inlet and outlet threads. Apply PTFE tape or pipe sealant to the male threads of your irrigation pipes. Connect the inlet pipe to the side marked 'IN' or with an arrow indicating flow direction, and the outlet pipe to the other side. Hand-tighten, then use a wrench for a final quarter to half turn, avoiding over-tightening.
- Connexió elèctrica: Connect the two wires from the solenoid to the corresponding 24V AC output terminals on your irrigation programmer. Ensure a secure, waterproof connection using appropriate connectors (e.g., waterproof wire nuts). This valve is compatible with any 24V AC multi-line programmer.
- Prova de fuites: Before burying the valve, slowly turn on the main water supply and check for any leaks at the connections.
- Comprovació del funcionament manual: The valve is equipped with a manual open/close device. Turn the manual override lever or screw to the 'OPEN' position to allow water flow, then return it to 'CLOSE' to stop flow. This confirms the valve's mechanical function.
5. Instruccions de funcionament
The Claber 90814 solenoid valve operates automatically in conjunction with a 24V AC irrigation programmer.
- Funcionament automàtic: Once connected to a compatible 24V AC programmer, the valve will open and close according to the schedule set on the programmer. When the programmer sends a 24V AC signal, the solenoid activates, opening the valve. When the signal is removed, the valve closes.
- Funcionament manual: En cas de poder outage or for testing purposes, you can manually open and close the valve using the integrated manual override mechanism. Locate the lever or screw on the solenoid and turn it to the 'OPEN' position for continuous water flow, or 'CLOSE' to stop the flow. Remember to return it to the 'AUTO' or 'CLOSED' position for automatic operation.
6. Manteniment
- Solenoid Filter: The solenoid is equipped with an anti-sand filter. Periodically inspect and clean this filter to prevent blockages and ensure proper valve operation.
- Hivernització: In regions prone to freezing temperatures, it is crucial to drain the irrigation system, including the solenoid valve, to prevent damage from freezing water. Consult your irrigation system's winterization guide.
- Inspecció general: Annually inspect the valve for any signs of wear, leaks, or damage. Ensure electrical connections remain secure and waterproof.
7. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| La vàlvula no s'obre | No power to solenoid; faulty wiring; clogged filter; low water pressure. | Check programmer schedule and power supply; inspect wiring connections; clean solenoid filter; verify water pressure. |
| La vàlvula no es tanca | Debris in valve; faulty solenoid; manual override engaged. | Flush the system to clear debris; inspect/replace solenoid; ensure manual override is in 'CLOSED' or 'AUTO' position. |
| Baix cabal d'aigua | Partially clogged filter; insufficient main water pressure. | Clean solenoid filter; check main water supply pressure. |
| Water leaks from valve | Loose connections; damaged O-rings/seals; cracked valve body. | Tighten connections; inspect and replace O-rings/seals; replace valve if body is cracked. |
8. Especificacions
- Número de model: 90814
- Marca: Clàber
- Tipus de vàlvula: Vàlvula solenoide
- Vol. Operatiutage: 24 V AC
- Inlet/Outlet Thread: 1" Female
- Pressió de funcionament: De 0.5 a 12 bar (7.25 a 174 psi)
- Caudal: 4.6 to 96 liters/minute
- Temperatura de funcionament: +5 °C a +70 °C (de 41 °F a 158 °F)
- Material: Fiberglass-reinforced nylon body, Stainless steel metal components
- Característiques: Anti-sand filter, Slow closing anti-water hammer device, Manual open/close control
- Especificacions compatibles: EN 1074-1, EN 1074-2, CE
- Dimensions del paquet: 13.4 x 12.4 x 8.4 cm
- Pes: 360 grams
9. Garantia i Suport
Claber products are manufactured to high-quality standards. For information regarding warranty coverage, technical support, or spare parts, please refer to the official Claber weblloc web o poseu-vos en contacte amb el vostre distribuïdor autoritzat local. Conserveu el rebut de compra com a comprovant de compra.