PowerWalker 10122041

Manual d'usuari del SAI de doble conversió PowerWalker VFI 1000 TG (en línia)

Model: 10122041

1. Introducció

This manual provides essential instructions for the installation, operation, and maintenance of your PowerWalker VFI 1000 TG Double-Conversion (Online) Uninterruptible Power Supply (UPS). This UPS is designed to provide clean, stable, and reliable power to your critical electronic equipment, protecting it from power fluctuations, surges, and outages. Please read this manual thoroughly before installation and operation to ensure proper use and safety.

Precaucions de seguretat

  • No obriu el SAI casing. No hi ha peces a l'interior que l'usuari pugui reparar. Demaneu totes les tasques de manteniment a personal de servei qualificat.
  • Assegureu-vos que el SAI estigui connectat a una presa de corrent de CA amb connexió a terra.
  • Do not block the ventilation openings of the UPS. Maintain adequate clearance around the unit for proper airflow.
  • Avoid installing the UPS in areas with excessive dust, humidity, or extreme temperatures.
  • In case of emergency, press the OFF button and disconnect the power cord from the AC outlet to disable the UPS.

2. Producte acabatview

Panell frontal

Davant view of PowerWalker VFI 1000 TG UPS with LCD display and control buttons

Imatge: Frontal view of the PowerWalker VFI 1000 TG UPS, showing the LCD display and control buttons.

The front panel features an LCD display that provides real-time information about the UPS status, including input/output voltage, battery level, and load level. Below the display are four control buttons:

  • ON/Silence: Powers on the UPS or silences the alarm.
  • DESACTIVAT: Apaga el SAI.
  • Seleccioneu: Navigates through display menus.
  • Introduïu: Confirma les seleccions o accedeix a submenús.

Panell posterior

posterior view of PowerWalker VFI 1000 TG UPS showing AC input, AC output, communication ports, and fan

Imatge: Part posterior view of the PowerWalker VFI 1000 TG UPS, detailing the AC input, four AC output ports, communication ports (RS-232, USB, Intelligent Slot, EPO), and cooling fan.

El panell posterior proporciona tots els punts de connexió necessaris:

  • Entrada de CA: Connects the UPS to the utility power source.
  • AC Output (4x C13): Provides power to connected equipment.
  • Port RS-232: For serial communication with a computer for monitoring and control.
  • Port USB: For USB communication with a computer for monitoring and control.
  • EPO (Emergency Power Off) Terminal: Allows for remote emergency shutdown of the UPS.
  • Ranura intel·ligent: Per a targetes de comunicació opcionals (per exemple, targeta SNMP).
  • Breaker (250VAC, 10A): Overcurrent protection for the UPS.

3. Configuració

3.1 Desembalatge i inspecció

  1. Carefully unpack the UPS and its accessories from the packaging.
  2. Inspect the unit for any shipping damage. If damage is found, do not operate the UPS and contact your dealer.
  3. Conserveu l'embalatge original per a futurs transports o emmagatzematges.

3.2 Col·locació

  • Place the UPS in a clean, dry, and well-ventilated indoor area.
  • Ensure the ambient temperature is between 0°C and 40°C (32°F and 104°F).
  • Avoid direct sunlight, heat sources, and excessive moisture.
  • Maintain at least 20 cm (8 inches) of clearance around the front, back, and sides of the UPS for proper ventilation.

3.3 Connecting the UPS

  1. Connecteu-vos a la xarxa elèctrica: Plug the UPS power cord into a grounded AC power outlet. The UPS will begin charging its internal batteries. Allow the batteries to charge for at least 8 hours before initial use to ensure optimal runtime.
  2. Connexió d'equips: Plug your critical electronic devices (e.g., computers, servers, network equipment) into the AC Output (C13) receptacles on the rear panel of the UPS. Ensure the total load does not exceed the UPS capacity (1000VA / 900W).
  3. Optional Communication: For advanced monitoring and automatic shutdown features, connect the UPS to your computer using either the RS-232 or USB cable. Install the provided monitoring software (if applicable) on your computer.
  4. Optional EPO: If remote emergency shutdown is required, connect an EPO switch to the EPO terminal. Consult a qualified electrician for proper installation of the EPO circuit.

4. Instruccions de funcionament

4.1 Encendre el SAI

After connecting the UPS to utility power and allowing the batteries to charge, press and hold the ON/Silence button on the front panel for approximately 2 seconds until you hear a beep. The UPS will perform a self-test, and the LCD display will illuminate, indicating normal operation.

4.2 Powering Off the UPS

  1. To power off the UPS and connected equipment, press and hold the OFF button for approximately 2 seconds until you hear a beep. The UPS will shut down, and the display will turn off.
  2. To completely remove power from the UPS, disconnect the power cord from the AC outlet.

4.3 Display and Button Functions

Utilitza el Seleccioneu button to cycle through various information screens on the LCD display, such as input voltage, voltage, capacitat de la bateria, percentatge de càrregatage, and operating mode. Use the Entra button to access sub-menus or confirm settings if available.

5. Manteniment

5.1 Cura de la bateria

  • The UPS batteries are designed for a specific lifespan. Factors like ambient temperature and discharge frequency can affect battery life.
  • Keep the UPS connected to AC power to ensure the batteries remain fully charged. Frequent deep discharges can shorten battery life.
  • Battery replacement should only be performed by qualified service personnel. Contact your dealer for battery replacement services.

5.2 Neteja

  • Ensure the UPS is powered off and disconnected from AC power before cleaning.
  • Use a soft, dry cloth to wipe the exterior of the UPS.
  • Do not use liquid or aerosol cleaners, as they may damage the unit.
  • Periodically check the ventilation openings for dust accumulation and gently clean them to ensure proper airflow.

5.3 Emmagatzematge

If the UPS is to be stored for an extended period, ensure the batteries are fully charged before storage. Store the unit in a cool, dry place. Recharge the batteries every three months to prevent battery degradation.

6. Solució De Problemes

This section addresses common issues you might encounter with your UPS. If the problem persists after attempting these solutions, please contact customer support.

ProblemaCausa possibleSolució
El SAI no s'encén.Sense alimentació d'entrada de CA.
Vol de bateria baixatage.
Check AC power cord connection and wall outlet.
Allow UPS to charge for at least 8 hours.
UPS is in bypass mode.Falla interna.
Sobrecàrrega.
Contacta amb l'assistència al client.
Reduir la càrrega connectada.
Temps de còpia de seguretat curt.Les bateries no estan completament carregades.
Batteries reaching end of life.
Sobrecàrrega.
Charge batteries for 8+ hours.
Contact service for battery replacement.
Reduir la càrrega connectada.
L'alarma sona contínuament.Sobrecàrrega.
Battery mode (normal operation).
Reduir la càrrega connectada.
This is normal during power outages. Press ON/Silence to mute.

7. Especificacions

CaracterísticaDetall
ModelVFI 1000 TG (10122041)
Capacitat1000 VA / 900 W
Tipus d'UPSDouble-Conversion (Online)
Sortides de CA4x IEC C13
Ports de comunicacióUSB HID, RS-232, Intelligent Slot
Apagada d'emergència (EPO)
Bateries2x 12V/9Ah (Lithium Ion)
Voltage12 Volts
Bateria Ampedat9 Amps
Dimensions del producte9.45 x 27.17 x 0.98 inches (approximate, may refer to packaging)
Pes de l'article9.3 kg (20.5 lliures)
ColorNegre
FabricantBlueWalker
ASINB01KZEON0I

8. Garantia i Suport

8.1 Informació de la garantia

This PowerWalker UPS comes with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official PowerWalker weblloc web per obtenir informació detallada sobre els termes i condicions de la garantia. Conserveu el comprovant de compra per a reclamacions de garantia.

8.2 Atenció al client

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your local dealer or PowerWalker customer support. Have your model number (10122041) and purchase date ready when contacting support.

Ask a question about this manual