Zamel RWS-211 J/N

Zamel RWS-211 J/N Wireless Switch and P-257/2 Remote Control User Manual

Model: RWS-211 J/N | Brand: Zamel

1. Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of the Zamel RWS-211 J/N 1-channel wireless power switch and the accompanying P-257/2 2-channel remote control. This system is designed for wireless control of various electrical devices within the EXTA FREE system, offering convenience and flexibility for home and industrial applications.

2. Informació de seguretat

WARNING: Electrical installation should only be performed by qualified personnel. Disconnect power before installation or maintenance.

  • Ensure the power supply is disconnected before attempting any installation or wiring.
  • The RWS-211 J/N switch is rated IP56, making it suitable for indoor and outdoor use in challenging weather conditions. However, ensure all connections are properly sealed to maintain this rating.
  • Do not exceed the maximum load capacity of 16A / 250V AC (4000VA AC1) per channel.
  • Operate within the specified temperature ranges: -20°C to +50°C for the RWS-211 J/N and -10°C to +55°C for the P-257/2 remote.
  • This device operates on 230V AC. Improper installation can lead to electric shock or fire.

3. Producte acabatview

3.1. Zamel RWS-211 J/N Wireless Switch

The RWS-211 J/N is a 1-channel wireless power switch designed for surface mounting. It allows remote control of lighting, ventilation, heating, irrigation, and other receivers. It features a robust IP56 enclosure, making it suitable for various environments.

Zamel RWS-211 J/N Wireless Switch with remote, showing applications like gate control, air conditioning, and garden lighting.
Figure 3.1: Zamel RWS-211 J/N Wireless Switch and P-257/2 Remote Control in various application scenarios.

This image illustrates the versatility of the RWS-211 J/N wireless switch, demonstrating its use in controlling outdoor gates, air conditioning units, and garden lights. The remote control is shown interacting with the switch to manage these devices wirelessly.

3.2. Zamel P-257/2 2-Channel Remote Control

The P-257/2 is a compact, battery-operated 2-button radio transmitter. It is used to control receivers within the EXTA FREE system, including the RWS-211 J/N. Each button can control a separate channel or function.

Zamel P-257/2 2-button remote control.
Figure 3.2: Zamel P-257/2 2-Channel Remote Control.

This image displays the P-257/2 remote control, highlighting its two distinct buttons for controlling different functions or devices. It is a key component for wirelessly interacting with the RWS-211 J/N switch.

4. Configuració

4.1. Mounting the RWS-211 J/N Switch

The RWS-211 J/N is designed for surface mounting. Choose a suitable location, considering the desired range and environmental conditions. Ensure the antenna is positioned for optimal signal reception.

4.2. Wiring the RWS-211 J/N Switch

Before wiring, ensure the main power supply is OFF.

  1. Open the RWS-211 J/N enclosure.
  2. Connect the 230V AC power supply to the terminals marked 'L' (Live) and 'N' (Neutral).
  3. Connect the device to be controlled (e.g., lamp, motor) to the output terminals. The RWS-211 J/N provides a potential-free NO (Normally Open) contact.
  4. Assegureu-vos que totes les connexions estiguin segures i aïllades correctament.
  5. Close the enclosure, ensuring the IP56 rating is maintained.
Wiring diagram for Zamel RWS-211 J/N wireless switch with a remote control.
Figure 4.1: Wiring Diagram for RWS-211 J/N.

This diagram illustrates the electrical connections for the RWS-211 J/N switch. It shows how to connect the 230V AC power supply (L and N) and the controlled load (represented by a lamp) to the switch's output terminals. The remote control is also depicted, indicating its role in wirelessly activating the switch.

4.3. Pairing the Remote Control (Learning Mode)

To enable the RWS-211 J/N to respond to the P-257/2 remote control, they must be paired:

  1. Apply power to the RWS-211 J/N switch.
  2. Locate the 'PROGRAMMING' button or jumper inside the RWS-211 J/N enclosure.
  3. Press and hold the 'PROGRAMMING' button for approximately 2 seconds until the LED indicator on the switch starts flashing. This indicates the switch is in learning mode.
  4. Within 10 seconds, press any button on the P-257/2 remote control that you wish to pair. The LED on the RWS-211 J/N will flash rapidly and then turn off, confirming successful pairing.
  5. Repeat for any other remote controls you wish to pair (up to 32 transmitters).

5. Instruccions de funcionament

5.1. Using the P-257/2 Remote Control

Once paired, simply press the assigned button on the P-257/2 remote control to activate or deactivate the connected device via the RWS-211 J/N switch. The remote's red LED indicates transmission and battery status.

5.2. Operating Modes of RWS-211 J/N

The RWS-211 J/N supports two operating modes: bistable and timed. These modes can typically be selected via a switch or jumper inside the enclosure (refer to internal diagram if available).

  • Bistable Mode: Each press of the remote button toggles the output state (ON/OFF).
  • Mode cronometrat: The output remains ON for a set duration (1 to 120 seconds) after a remote button press, then automatically turns OFF. The time setting is independent for each channel.

6. Manteniment

6.1. P-257/2 Remote Control Battery Replacement

The P-257/2 remote control is powered by a CR2032 battery, with an estimated life of 3 years depending on usage. When the red LED on the remote appears dim or fails to light during transmission, replace the battery:

  1. Obriu amb cura el comandament a distància casing.
  2. Traieu la bateria CR2032 antiga.
  3. Inseriu una nova bateria CR2032, assegurant la polaritat correcta.
  4. Tanqueu el comandament a distància casing de manera segura.

6.2. Neteja

The RWS-211 J/N switch has an IP56 rating, meaning it is protected against dust ingress and powerful water jets. Clean the exterior with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the enclosure remains sealed after cleaning.

7. Solució De Problemes

7.1. Device Not Responding to Remote

  • Check if the RWS-211 J/N switch has power.
  • Verify that the P-257/2 remote control battery is not depleted (check the red LED indicator).
  • Ensure the remote control is paired with the switch. If unsure, repeat the pairing process (Section 4.3).
  • Check for obstructions between the remote and the switch.

7.2. Short Operating Range

The specified range of up to 350m (RWS-211 J/N) and 300m (P-257/2) is for open air. Obstacles can significantly reduce the effective range. Consider the following material impacts:

Diagram showing signal range loss through various building materials.
Figure 7.1: Approximate Range Loss Due to Materials.

This image illustrates how different building materials can affect the wireless signal range. For example, wood/gypsum causes 5-20% loss, glass 10-20%, brick 10-40%, concrete 40-80%, and metal 50-100%. If experiencing short range, consider the materials between the remote and the switch. The range can be extended using an intermediate transmitter (RTN-01).

8. Especificacions

8.1. Zamel RWS-211 J/N Wireless Switch

CaracterísticaEspecificació
ModelRWS-211 J/N
Nominal Connection Voltage230 V AC
Voltage Variació-15% a +10%
Nominal Power (Standby/Operation)1.1 W / 1.5 W
Nombre de canals1
Maximum Transmitters32
Freqüència de ràdio868.32 MHz
Transmissió de ràdioUn sol sentit
Range (Open Air)Up to 350 m (extendable with RTN-01)
Relay Contact Parameters1 x 16 A / 250 V AC 4000 VA AC1
Tipus de contacte1 x NO potential-free contact
Mode de funcionamentBistable, Timed (1-120 s)
MuntatgeSuperfície
Classe de protecció de tancamentIP56
Interval de temperatura-20 °C a +50 °C
Classe de proteccióIII
Dimensions (L x A x A)127 x 120 x 60 mm
Pes0.39 kg
Normes de referènciaPN-EN 60669, PN-EN 60950, PN-EN 61000

8.2. Zamel P-257/2 2-Channel Remote Control

CaracterísticaEspecificació
ModelP-257/2
TipusRadio Transmitter (Remote Control)
Nombre de botons2
Nominal Connection Voltage3 V DC (CR2032 battery)
Freqüència de ràdio868.32 MHz
Transmissió de ràdioUn sol sentit
Range (Open Air)Fins a 300 m
Optical DisplayRed LED (transmission/battery status)
Durada de la bateriaApprox. 3 years (usage dependent)
Interval de temperatura-10 °C a +55 °C
Classe de protecció de tancamentIP20
Classe de proteccióIII
Dimensions (L x A x A)74 x 33 x 11.5 mm
Pes0.018 kg
Normes de referènciaPN-ETSI EN 300 220-1, PN-ETSI EN 300 220-2

9. Garantia i Suport

For warranty information and technical support, please refer to the documentation provided with your purchase or contact Zamel customer service directly. Keep your proof of purchase for warranty claims.

© 2024 Zamel. All rights reserved.

Documents relacionats - RWS-211 J/N

Preview Catàleg Sterowanie Roletami Zamel EXTA | Systemy Automatyki Budynkowej
Compleksowy catalog systemów sterowania roletami Zamel EXTA, EXTA FREE, EXTA LIFE oraz SUPLA. Odkryj przewodowe i bezprzewodowe rozwiązania dla intelligentnego domu, w tym sterowniki dopuszkowe, modulowe, radiowe i Wi-Fi.
Preview ZAMEL ROP-01 Radiowy odbiornik dopuszkowy 1-kanałowy - Instrukcja obsługi
Instrukcja obsługi i specyfikacja techniczna dla radiowego odbiornika dopuszkowego 1-kanałowego ZAMEL ROP-01. Dowiedz się, jak zainstalować, zaprogramować i obsługiwać urządzenie w systemie EXTA FREE.
Preview Sterownik rolet ZAMEL SRP-01 - Instrukcja obsługi
Instrukcja obsługi sterownika rolet ZAMEL SRP-01. Zawiera dane techniczne, schematy podłączenia, instrukcję montażu oraz warunki gwarancji.
Preview ZAMEL LOT-21 Radiowy Odbiornik Regulatora (Kotła) - Instrukcja Obsługi
Instrukcja instalacji i obsługi radiowego odbiornika ZAMEL LOT-21, przeznaczonego do sterowania kotłem i ogrzewaniem w systemie Exta Life.
Preview Zamel SRP-22 Sterownik Rolet Dopuszkowy - Instrukcja i Specyfikacja Techniczna
Kompleksowa instrukcja obsługi i specyfikacja techniczna sterownika rolet Zamel SRP-22. Zawiera informacje o instalacji, konfiguracji, programowaniu radiowym i przez aplikację mobilną exta life, a także dane techniczne.
Preview ZCM-11, ZCM-11/E, ZCM-11P/U Time Programmer Instruction Manual
Comprehensive instruction manual for the ZAMEL ZCM-11 series weekly time programmers. Includes installation, configuration, programming, and technical specifications.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.