1. Introducció
The Lightkiwi H5576 Digital Timer is designed to provide automated control for your low voltage landscape lighting system. This timer offers convenience and energy efficiency by allowing you to program specific on/off times for your lights. Its robust features and easy-to-read display make it an ideal solution for managing your outdoor illumination.
Característiques principals:
- Automatically Turns Your Low Voltage Lighting System On/Off
- Easy Set Up Operation
- Large, Easy to Read Digital LCD Display
- Automatic or Manual Operation
- Program Up To 18 On/Off Settings Per Week

2. Informació de seguretat
Please read all instructions carefully before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.
- No submergiu el temporitzador en aigua ni l'exposeu a una humitat excessiva.
- Ensure the timer is properly plugged into a compatible outlet.
- Do not exceed the maximum electrical ratings: 15 Amps, 1875 Watts Resistive or General Purpose; 8 Amps, 1000 Watts Tungsten.
- This timer is designed for 125 Volts AC, 60 Hz applications.
- Mantenir fora de l'abast dels nens.
- Desconnecteu l'alimentació abans de netejar o realitzar qualsevol manteniment.
3. Instruccions de configuració
The Lightkiwi H5576 Digital Timer is designed for easy integration with your low voltage landscape lighting system. It is specifically compatible with the Lightkiwi 300 Watt Transformer (Model# W9715). Please note that this timer does not fit into 75 watt transformers due to their built-in mechanical timers.
Configuració inicial:
- Desempaqueta el temporitzador: Traieu amb cura el temporitzador del seu embalatge.
- Inspect the Timer: Comproveu si hi ha danys visibles.
- Connectar: Insert the timer directly into a standard 125V AC, 60Hz wall outlet or the designated timer receptacle on your compatible Lightkiwi transformer. The timer features a battery backup to retain settings during power outages.
- Connectar el dispositiu: Plug the device you wish to control (e.g., your landscape lighting transformer) into the outlet on the side of the digital timer.


Vídeo de configuració:
Watch this official Lightkiwi video for a visual guide on setting up your timer with a Lightkiwi transformer:
Video: Timers for Lightkiwi Transformer. This video demonstrates the compatibility and connection of Lightkiwi timers with Lightkiwi transformers.
4. Instruccions de funcionament
The H5576 Digital Timer allows for both automatic and manual operation, with the ability to program up to 18 on/off settings per week. The large LCD display ensures easy readability.
Configuració de l'hora actual:
- Premeu el botó TEMPS botó. La pantalla de les hores parpellejarà.
- Utilitza el UP i ABAIX botons per ajustar l'hora.
- Premeu TEMPS again. The minute display will flash.
- Utilitza el UP i ABAIX botons per ajustar els minuts.
- Premeu TEMPS de nou. El dia de la setmana parpellejarà.
- Utilitza el UP i ABAIX botons per seleccionar el dia actual.
- Premeu TEMPS per confirmar i sortir del mode de configuració de l'hora.
Programming On/Off Cycles:
You can set up to 18 distinct ON/OFF programs. Each program consists of an ON time and an OFF time.
- Premeu el botó SET button. The display will show "1 ON" and the hour will flash.
- Ús UP i ABAIX to set the desired ON hour for program 1.
- Premeu SET. Set the ON minutes using UP i ABAIX.
- Premeu SET. Set the day(s) of the week for this ON program using UP i ABAIX. You can choose individual days, weekdays, weekends, or all days.
- Premeu SET. The display will show "1 OFF" and the hour will flash.
- Repeat steps 2-4 to set the desired OFF time and day(s) for program 1.
- Continueu prement SET to cycle through programs 2-18 and set them as needed. If you do not need all 18 programs, simply press CTD per sortir del mode de programació.
Anulació manual:
Per encendre o apagar manualment el dispositiu connectat, premeu el botó MANUAL button. Each press will cycle through ON, OFF, and AUTO modes. In AUTO mode, the timer will follow your programmed settings.
Funció aleatòria:
El RND (Random) button can be used to activate a random on/off pattern, which can be useful for security purposes when you are away. Consult the full user guide (link in product documents) for detailed instructions on using the random function.
5. Manteniment
The Lightkiwi H5576 Digital Timer requires minimal maintenance to ensure long-lasting performance.
- Neteja: Wipe the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the timer is unplugged before cleaning.
- Emmagatzematge: Si guardeu el temporitzador durant un període prolongat, assegureu-vos que estigui net i sec. Guardeu-lo en un lloc fresc i sec, allunyat de la llum solar directa.
- Còpia de seguretat de la bateria: The internal battery maintains settings during power outages. If the display is blank or settings are lost frequently, the battery may need to be recharged by keeping the unit plugged in for several hours.
6. Solució De Problemes
If you encounter issues with your Lightkiwi H5576 Digital Timer, please refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| La pantalla del temporitzador està en blanc. | No power; internal battery drained. | Ensure the timer is securely plugged into a live outlet. Leave it plugged in for several hours to recharge the internal battery. |
| Connected device does not turn on/off at programmed times. | Incorrect programming; timer in manual mode; power outage. | Verify your ON/OFF programs are set correctly. Press the MANUAL button until the timer is in AUTO mode. Check for power outages. |
| Dificultat per programar el temporitzador. | Desconeixement de la seqüència de botons. | Refer to the "Operating Instructions" section (Section 4) and follow the steps carefully. It may be helpful to unplug the timer and program it in a comfortable setting before re-installing. |
| Timer trips circuit breaker. | Overload; incompatible transformer. | Ensure the connected load does not exceed the timer's maximum wattage (1875W). Verify compatibility with your transformer (e.g., Lightkiwi 300W Transformer Model# W9715). Do not use with 75W transformers. |
7. Especificacions
| Especificació | Detall |
|---|---|
| Número de model | H5576 |
| Marca | Lightkiwi |
| Color | Blanc |
| Material | Plàstic |
| Entrada Voltage | 125 volts CA, 60 Hz |
| Max. Input Current/Watt | 15 Amps, 1875 Watts Resistive or General Purpose |
| Classificació de tungstè | 8 Amps, 1000 watts de tungstè |
| Nombre de configuracions | Up to 18 On/Off settings per week |
| Dimensions del producte | 3.5 x 3 x 2.5 polzades |
| Pes de l'article | 3.84 unces |
| Certificacions | Llistat per ETL |
| UPC | 615953178111 |
8. Garantia i Suport
Lightkiwi is committed to providing high-quality products. For specific warranty information regarding your H5576 Digital Timer, please refer to the documentation included with your purchase or visit the official Lightkiwi weblloc.
Atenció al client:
If you have any questions, require technical assistance, or need to report an issue, please contact Lightkiwi customer support. You can find contact information and additional resources by visiting the Lightkiwi Brand Store on Amazon o el seu oficial weblloc.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.