1. Introducció

The Fieldpiece TC24 Pipe Clamp Thermocouple is a robust and accurate tool designed for measuring temperatures on pipes in HVAC/R systems. This manual provides essential information for the proper setup, operation, and maintenance of your TC24 to ensure reliable performance.

Fieldpiece TC24 Pipe Clamp Termoparell

Figure 1: The Fieldpiece TC24 Pipe Clamp Thermocouple, a yellow and black device designed for accurate temperature measurements on pipes.

2. Configuració

2.1 Desembalatge i inspecció

Carefully remove the TC24 from its packaging. Inspect the device for any signs of damage. If any damage is found, contact your supplier immediately.

2.2 Battery Installation (if applicable)

The TC24 may require batteries for operation. Locate the battery compartment, typically on the underside or side of the unit. Insert the specified batteries, ensuring correct polarity. Close the compartment securely.

2.3 Connexió a un comptador

The TC24 is a K-type thermocouple and requires connection to a compatible multimeter or HVAC/R analyzer. Plug the thermocouple's K-type connector into the appropriate input jacks on your measuring device. Ensure a secure connection for accurate readings.

3. Instruccions de funcionament

3.1 Encès

Press and hold the power button on the TC24 (if present) until the indicator light illuminates, signaling that the device is active and ready for use. If no power button is present, the device will activate upon connection to a powered meter.

3.2 Attaching to a Pipe

Obriu el clamp jaws by squeezing the handle. Position the clamp around the pipe where you wish to measure the temperature. Release the handle to allow the jaws to firmly grip the pipe. The TC24 is designed to fit pipes ranging from 3/8 inch to 1 3/8 inches in diameter.

3.3 Selecting Measurement Mode (if applicable)

Some models may feature a switch to select between 'Suction' and 'Liquid' line measurements. Adjust this switch according to the type of line you are measuring for optimized accuracy.

3.4 Reading Temperature

Un cop el clamp is securely attached, the temperature reading will be displayed on your connected multimeter or analyzer. Refer to your meter's manual for specific display and data logging functions. For wireless models, readings can be transmitted to a compatible mobile application, such as the Fieldpiece Job Link app, allowing for remote monitoring and data analysis.

4. Manteniment

4.1 Neteja

Keep the pipe clamp clean and free of dirt, grease, and debris. Use a soft, damp cloth to wipe down the exterior. Do not use abrasive cleaners or solvents, as these can damage the device. Ensure the sensor contact points are clean for accurate readings.

4.2 Emmagatzematge

When not in use, store the TC24 in a dry, cool place, away from direct sunlight and extreme temperatures. Use the original carrying case or a protective pouch to prevent physical damage.

4.3 Substitució de la bateria

If your TC24 model uses replaceable batteries, replace them when the low battery indicator appears on your connected meter or if the device fails to power on. Always use the recommended battery type.

5. Solució De Problemes

5.1 Lectures inexactes

  • Assegureu-vos que el clamp is securely and properly seated on the pipe, making good contact.
  • Clean the sensor contact points on the clamp.
  • Verify that the TC24 is correctly connected to your measuring device.
  • Check the battery level of the TC24 and your measuring device.

5.2 El dispositiu no s'encén

  • Replace the batteries if applicable.
  • Assegureu-vos que el botó d'engegada estigui premut i mantingut prou premut.
  • Verify the connection to the measuring device if it draws power from the meter.

5.3 Connectivity Issues (Wireless Models)

  • Ensure Bluetooth is enabled on your mobile device and the TC24.
  • Confirm that the Fieldpiece Job Link app is up-to-date.
  • Try re-pairing the TC24 with your mobile device.

6. Especificacions

CaracterísticaDetall
Número de modelTC24
MarcaPeça de camp
MaterialMetall
Interval de mida de canonada3/8 inch to 1 3/8 inches
Dimensions de l'article (L x A x A)3.5 x 3 x 7.5 polzades
Pes de l'article6.4 unces (0.4 lliures)
Colorgroc
Fabricat aTaiwan

7. Garantia

For detailed warranty information regarding your Fieldpiece TC24 Pipe Clamp Thermocouple, please refer to the warranty card included with your product or visit the official Fieldpiece weblloc web. Els termes i condicions de la garantia poden variar segons la regió i la data de compra.

8. Suport

If you require technical assistance, have questions about your product, or need to arrange for service, please contact Fieldpiece customer support. Contact information can typically be found on the Fieldpiece weblloc o a l'embalatge del producte.

© 2026 Fieldpiece. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.