EASYGUARD P2

EASYGUARD P2 Replacement Push Start Stop Button User Manual

Model: P2

Introducció

This manual provides instructions for the installation and operation of the EASYGUARD P2 Replacement Push Start Stop Button. This button is designed as a replacement part and is only compatible with specific EASYGUARD car alarm systems.

Compatibilitat: This replacement button is exclusively compatible with EASYGUARD EC002 series PKE car alarms, EC110 series, ES002 series, and ES003 series systems. It is not designed for use with other car alarm systems or as a standalone product.

Producte acabatview

The EASYGUARD P2 Push Start Stop Button features a dynamic LED illumination that changes color based on the vehicle's status:

  • When the system is disarmed, or the ACC/ON ignition is active, the button illuminates in blau.
  • Once the engine is started, the button illumination changes to vermell.
EASYGUARD P2 Push Start Stop Button showing blue and red illumination states with dimensions

Imatge: The EASYGUARD P2 Push Start Stop Button illustrating its blue illumination when disarmed or in ACC/ON mode, and red illumination when the engine is running. Key dimensions are also shown: 28mm, 41mm, and 52mm.

EASYGUARD P2 Push Start Stop Button components including button, mounting bracket, and wiring harness

Imatge: Components included with the EASYGUARD P2 Push Start Stop Button: the button itself, a mounting bracket, and the necessary wiring harness for connection.

Configuració i instal·lació

This replacement button is intended for integration with existing EASYGUARD EC002, EC110, ES002, or ES003 series systems. Professional installation is recommended to ensure correct wiring and functionality.

Comprovacions prèvies a la instal·lació:

  1. Verify that your existing car alarm system is one of the compatible EASYGUARD series (EC002, EC110, ES002, ES003).
  2. Assegureu-vos que la bateria del vehicle estigui desconnectada abans de començar qualsevol treball elèctric.
  3. Identify the location for the new push start button. Ensure sufficient space behind the mounting surface for the button and its wiring.

Passos d'instal·lació:

  1. Remove Existing Button (if applicable): Carefully disconnect and remove the old push start button from its mounting location.
  2. Preparació de la ubicació de muntatge: If installing in a new location, drill a hole of appropriate diameter (refer to product dimensions for exact size, approximately 41mm for the main body) for the button.
  3. Connecteu el cablejat: Connect the wiring harness of the P2 button to the corresponding wires of your EASYGUARD car alarm system. Refer to your specific EASYGUARD system's wiring diagram for accurate connections. Pay close attention to power, ground, ignition, and start signal wires.
  4. Munta el botó: Insert the P2 button into the prepared opening. Secure it using the provided mounting bracket and hardware. Ensure the button is firmly seated and does not wobble.
  5. Cablejat segur: Route and secure all wiring to prevent interference with moving parts or accidental disconnection.
  6. Torneu a connectar la bateria: Once all connections are secure and verified, reconnect the vehicle's battery.

Nota: Incorrect wiring can damage the product or vehicle's electrical system. If you are unsure about any step, consult a qualified automotive technician.

Instruccions de funcionament

The EASYGUARD P2 Push Start Stop Button functions in conjunction with your compatible EASYGUARD car alarm system. Its operation is typically as follows:

  1. Disarm System / ACC / ON: When your EASYGUARD system is disarmed, or the ignition is set to ACC or ON, the P2 button will illuminate in blau.
  2. Arrencada del motor: With the system disarmed and the brake pedal pressed, press the P2 button once to start the engine. Upon successful engine start, the button's illumination will change to vermell.
  3. Aturar el motor: To stop the engine, press the P2 button once while the vehicle is stationary. The button's illumination will revert to blau (or off, depending on the system's disarmed state).
  4. ACC/ON Mode without Starting: Depending on your EASYGUARD system, a quick press of the button without pressing the brake may cycle through ACC and ON modes. Refer to your main EASYGUARD system manual for specific details on this functionality.

Important: Always ensure the vehicle is in park (P) or neutral (N) and the parking brake is engaged before starting or stopping the engine.

Manteniment

The EASYGUARD P2 Push Start Stop Button requires minimal maintenance. Follow these guidelines to ensure its longevity:

  • Neteja: Wipe the button surface with a soft, dry, or slightly damp drap. Eviteu utilitzar netejadors abrasius, dissolvents o productes químics agressius, ja que poden danyar l'acabat o els components interns.
  • Inspecció: Periodically check the button for any signs of physical damage, loose connections, or unusual operation.
  • Condicions ambientals: While designed for automotive use, avoid exposing the button to extreme temperatures or excessive moisture beyond normal vehicle operating conditions.

Resolució de problemes

If you encounter issues with your EASYGUARD P2 Push Start Stop Button, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
Button does not illuminate.
  • Sense font d'alimentació.
  • Connexió de cablejat solta.
  • Faulty button.
  • Check power supply to the EASYGUARD system.
  • Inspeccioneu totes les connexions del cablejat per detectar si hi ha fluïdesa o corrosió.
  • If connections are secure and power is present, the button may be faulty and require replacement.
Button illuminates but engine does not start.
  • Brake pedal not pressed.
  • Incorrect wiring to the main EASYGUARD unit.
  • Issue with the main EASYGUARD system or vehicle's starter.
  • Ensure the brake pedal is fully depressed when attempting to start.
  • Verify wiring connections between the button and the EASYGUARD system, especially the start signal wire.
  • Consult the manual for your main EASYGUARD system or a qualified technician.
Button color does not change.
  • Incorrect wiring for status signals.
  • Internal button fault.
  • Check wiring connections related to ACC, ON, and engine running status signals from the EASYGUARD system.
  • If wiring is correct, the button may be faulty.

For further assistance, contact EASYGUARD customer support or a certified installer.

Especificacions

CaracterísticaDetall
Número de modelP2
MarcaGUARDIA FÀCIL
CompatibilitatEASYGUARD EC002, EC110, ES002, ES003 series car alarm systems
Mode d'operacióPush, Push Start, Start Stop
Tipus de contacteNormalment obert
Tipus de connectorMicro USB (internal connection, not external user port)
Tipus de circuit1 vies
Tipus de muntatgeSuport al tauler
Tipus d'actuadorPulsador
Material de contacteMetall
Classificació de protecció internacionalIP00
Nombre de llocs2
Mètode de controlToca
Protocol de connectivitatX-10 (likely refers to the main system's protocol)
Color d'il·luminacióBlue (Disarm/ACC/ON), Red (Engine Started)
Recompte d'unitats1
Dimensions de l'article (L x A x A)7.87 x 3.15 x 1.18 polzades (dimensions de l'embalatge)
Pes de l'article1.34 unces
Voltage12 Volts
FabricantZhongshan easyguard electronics co.,ltd

Garantia i Suport

Specific warranty details for the EASYGUARD P2 Replacement Push Start Stop Button are typically provided with the original EASYGUARD car alarm system or can be obtained directly from EASYGUARD customer service.

For technical support, installation inquiries, or warranty claims, please contact EASYGUARD through their official channels. Refer to the documentation included with your main EASYGUARD system for contact information or visit the official EASYGUARD weblloc.

Fabricant: Zhongshan easyguard electronics co.,ltd

© 2024 EASYGUARD. All rights reserved.

Ask a question about this manual