Legrand 091333

Legrand 091333 Neptune Double Earthed Socket Instruction Manual

Model: 091333 | Marca: Legrand

1. Introducció

Thank you for choosing the Legrand 091333 Neptune Double Earthed Socket. This product is designed to provide two electrical outlets from a single wall box, offering convenience and reliability. It features a 16 Ampere current rating and is suitable for standard electrical installations. This manual provides essential information for the safe and correct installation, operation, and maintenance of your new socket. Please read these instructions thoroughly before beginning installation or use.

2. Informació de seguretat

ADVERTIMENT: Electrical installation should only be performed by a qualified electrician or competent person. Incorrect installation can lead to electric shock, fire, or serious injury.

  • Always disconnect the main power supply at the consumer unit/fuse box before commencing any electrical work.
  • Verify that the power is off using a suitable voltagEl provador abans de tocar cap cable.
  • Ensure all wiring connections are secure and correctly terminated.
  • No supereu la intensitat màxima nominal de 16 Ampere or power rating of 3680 Watts.
  • This product is designed for indoor use in dry conditions. Do not install in wet or damp environments unless specifically rated for such use.
  • Keep children away from electrical outlets.

3. Contingut del paquet

The Legrand 091333 Neptune Double Earthed Socket package typically includes:

  • 1 x Legrand 091333 Neptune Double Earthed Socket (complete with holder and white plate)
Legrand 091333 Neptune Double Earthed Socket in packaging

Figure 3.1: Legrand 091333 Neptune Double Earthed Socket in its original packaging.

4. Especificacions

CaracterísticaDetall
MarcaLegrand
Model091333
ColorBlanc
MaterialPlàstic
Voltage230 V
Valoració actual16 Ampere
Potència nominal3680 watts
Tipus de connexióSchuko (tipus F)
Total Outlets2 (doble)
Tipus de muntatgeHooks or Screws
posterior view of Legrand 091333 socket showing wiring terminals

Figura 4.1: posterior view of the socket, illustrating the wiring terminals for connection.

Davant view of Legrand 091333 double earthed socket

Figura 4.2: Frontal view of the Legrand 091333 double earthed socket, showing the two Schuko outlets.

Diagram showing various Legrand Neptune sockets and connectivity options

Figura 4.3: Mésview of Legrand Neptune socket types, including the double earthed socket.

5. Configuració i instal·lació

Important: Installation must be carried out by a qualified electrician in accordance with local wiring regulations.

  1. Desconnexió d'alimentació: Locate the consumer unit/fuse box for the circuit where the socket will be installed. Turn off the main power supply to prevent electric shock. Use a voltage tester to confirm that the power is completely off at the installation point.
  2. Prepareu l'àrea d'instal·lació: If replacing an existing socket, carefully remove its cover plate and disconnect the old wiring. If installing a new socket, ensure a suitable wall box (flush or surface mounted) is correctly installed and secured, with appropriate cable entry.
  3. Connexió de cable:
    • Identify the Live (brown or red), Neutral (blue or black), and Earth (green/yellow) wires.
    • Strip approximately 10-12mm of insulation from each wire end.
    • Connect the wires to the corresponding terminals on the back of the Legrand 091333 socket. The terminals are typically marked:
      • L for Live
      • N for Neutral
      • for Earth (ground)
      Ensure connections are tight and no bare wire is exposed outside the terminals. The socket features automatic terminals for easy, screw-less connection, or can be secured with screws if applicable.
  4. Mounting the Socket: Carefully push the wired socket back into the wall box. Secure the socket to the wall box using the provided screws or by engaging the mounting hooks. Ensure the socket is flush with the wall and level.
  5. Fixeu la placa frontal: Secure the white faceplate onto the socket mechanism.
  6. Restaura l'alimentació: Once the installation is complete and all connections are checked, restore the main power supply at the consumer unit/fuse box.
  7. Prova: Test the socket with a suitable appliance to ensure it is functioning correctly.
Part posterior detallada view of Legrand 091333 socket showing terminal connections

Figure 5.1: Close-up of the rear terminals, indicating connection points for Live, Neutral, and Earth wires.

Davant view of Legrand 091333 double earthed socket with screw visible

Figura 5.2: Frontal view of the socket, showing the central screw for securing the faceplate.

Side profile of Legrand 091333 double earthed socket showing depth

Figura 5.3: Pro lateralfile of the socket, illustrating its depth for flush mounting.

6. Instruccions de funcionament

The Legrand 091333 Neptune Double Earthed Socket is designed for straightforward operation.

  1. Connectar: Insert the plug of your electrical appliance into one of the two available outlets. Ensure the plug is fully inserted.
  2. Encès: If the appliance has its own power switch, turn it on. The socket itself does not have an on/off switch.
  3. Treure l'endoll: To disconnect an appliance, firmly grasp the plug and pull it straight out of the socket. Do not pull by the cable.

Ensure that the total power consumption of all connected devices does not exceed the socket's maximum rating of 3680 Watts (16 Ampere at 230V).

Davant view of Legrand 091333 double earthed socket with Legrand logo

Figura 6.1: Frontal view of the Legrand 091333 socket, ready for use.

7. Manteniment

The Legrand 091333 Neptune Double Earthed Socket requires minimal maintenance.

  • Neteja: To clean the socket, first ensure no appliances are plugged in. Wipe the surface with a soft, dry, or slightly damp cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the plastic or create an electrical hazard.
  • Inspecció: Periodically inspect the socket for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, disconnect power to the circuit and have the socket inspected and replaced by a qualified electrician.

8. Solució De Problemes

If you encounter issues with your Legrand 091333 Neptune Double Earthed Socket, consider the following:

ProblemaCausa possibleSolució
No hi ha alimentació des de la presa.
  • L'interruptor de circuit s'ha disparat o el fusible s'ha trencat.
  • Connexió de cablejat solta.
  • Faulty appliance.
  • Check your consumer unit/fuse box and reset the breaker or replace the fuse.
  • (For loose wiring) Disconnect power and have a qualified electrician inspect and re-secure connections.
  • Test with a different, known-working appliance.
Socket feels warm.
  • Circuit sobrecarregat.
  • Connexió de cablejat solta.
  • Unplug some appliances to reduce the load.
  • (For loose wiring) Disconnect power and have a qualified electrician inspect and re-secure connections immediately.
Plug does not fit or is loose.
  • Incompatible plug type.
  • Damaged socket.
  • Ensure your appliance has a Type F (Schuko) plug. Refer to Figure 8.1 for common plug types.
  • If the socket is damaged, disconnect power and have it replaced by a qualified electrician.
Diagram illustrating various international plug and socket types

Figura 8.1: Examples of different plug and socket types. The Legrand 091333 is a Type F (Schuko) socket.

9. Garantia i Suport

Legrand products are manufactured to high standards and are backed by a manufacturer's warranty. Specific warranty terms and conditions may vary by region. Please retain your proof of purchase for warranty claims.

For technical support, warranty inquiries, or further assistance, please contact Legrand customer service or visit the official Legrand website. Contact details can typically be found on the product packaging or the Legrand regional weblloc per al vostre país.

Legrand Oficial Weblloc: www.legrand.com

© 2023 Legrand. Tots els drets reservats. La informació d'aquest manual està subjecta a canvis sense previ avís.

Ask a question about this manual