EPEVER CC-USB-RS485-150U

EPEVER USB to RS485 PC Communication Cable (CC-USB-RS485-150U)

Manual d'instruccions

Model: CC-USB-RS485-150U

1. Producte acabatview

The EPEVER CC-USB-RS485-150U is a USB to RS-485 communication cable designed to facilitate data exchange between EPEVER MPPT solar charge controllers and a personal computer. This cable enables users to monitor controller performance, view operational data, and configure various parameters using the dedicated Solar Station PC software.

The cable has a length of 1.5 meters and connects directly to the RS-485 port (RJ45 connector) on the solar charge controller.

EPEVER USB to RS485 PC Communication Cable

The EPEVER CC-USB-RS485-150U cable, featuring a USB connector on one end and an RJ45 connector on the other, designed for PC communication with EPEVER solar charge controllers.

2. Contingut del paquet

  • 1x EPEVER CC-USB-RS485-150U Communication Cable

3. Informació de seguretat

Please read and understand all instructions before installation and operation. Observe the following safety guidelines:

  • Ensure all power sources are disconnected from the solar charge controller before connecting or disconnecting the communication cable.
  • Always connect the battery to the solar charge controller first, and disconnect it last.
  • Do not use an electric screwdriver for terminal connections to avoid over-tightening or damage.
  • This cable is specifically designed for EPEVER/EPsolar brand solar charge controllers. Compatibility with other brands is not guaranteed.

4. Configuració i instal·lació

4.1 Connecting the CC-USB-RS485-150U Cable

  1. Locate the RS-485 communication port (RJ45 connector) on your EPEVER solar charge controller.
  2. Plug the RJ45 end of the CC-USB-RS485-150U cable into the controller's RS-485 port.
  3. Connect the USB end of the cable to an available USB port on your personal computer.

4.2 Instal·lació del programari

To utilize the communication cable, you will need to install the EPEVER Solar Station PC software. This software is typically available for download from the official EPEVER website. Follow the software's installation instructions. Drivers for the USB to RS485 converter may be automatically installed by your operating system or included with the software package.

Connection diagram for EPEVER solar charge controller system

This diagram illustrates the typical wiring setup for an EPEVER solar charge controller, showing connections for solar panels, battery, DC load, and AC load via an inverter. It also highlights the communication port for accessories like the RS485 cable.

5. Funcionament

Once the cable is connected and the Solar Station PC software is installed, you can begin monitoring and configuring your solar charge controller.

5.1 Monitoring System Data

The PC software provides a comprehensive interface to view real-time and historical data from your solar charge controller. This includes:

  • Bateria voltage i corrent
  • Panell solar voltage and current (PV parameters)
  • Càrrega voltage i corrent
  • Temperatura del sistema
  • Energy statistics (e.g., daily generated energy)

5.2 Configuració de paràmetres

The software allows for advanced configuration of the solar charge controller, including:

  • Battery type selection (Sealed, Gel, Flooded, Lithium, User-defined)
  • Load working mode settings (e.g., light control, manual control, timer control)
  • Charging and discharging parameters for various battery types

For detailed instructions on setting specific parameters, refer to the Solar Station PC software's user manual or the EPEVER support resources.

This video provides a visual guide to setting up an EPEVER MPPT solar charge controller, including unboxing, connecting solar panels, batteries, and loads, and configuring battery and load parameters via the controller's interface. It also highlights the communication port for accessories like the RS485 cable.

6. Solució De Problemes

If you encounter issues with the CC-USB-RS485-150U cable or communication, consider the following:

  • Comprovació de la connexió: Ensure the RJ45 connector is securely plugged into the controller's RS-485 port and the USB connector is firmly seated in your computer's USB port.
  • Instal·lació del controlador: Verify that the necessary USB drivers are correctly installed on your computer. Sometimes, reinstalling the Solar Station PC software can resolve driver issues.
  • Compatibilitat del programari: Ensure you are using the correct version of the Solar Station PC software compatible with your specific EPEVER controller model.
  • Potència del controlador: Confirm that your solar charge controller is powered on and functioning correctly.
  • Integritat del cable: Inspeccioneu el cable per detectar qualsevol dany o doblec visible.

For further assistance, please contact the Goland Century technical support team, the official authorized sales agent for EPEVER products.

7. Especificacions

CaracterísticaEspecificació
Número de modelCC-USB-RS485-150U (RS485)
Longitud del cable1.5 metres
Connector Type (Controller)RJ45
Connector Type (PC)USB
CompatibilitatEPEVER/EPsolar brand solar charge controllers
Pes de l'article1.44 unces (0.04 quilograms)
Dimensions del paquet4.61 x 3.03 x 1.26 polzades
UPC689771609010

8. Garantia i Suport

EPEVER products are supported by authorized sales agents. For technical support, troubleshooting, or warranty inquiries, please contact the vendor from whom you purchased the product. Goland Century, an official authorized sales agent for EPEVER, provides free technical support to their customers.

For additional resources and software downloads, please visit the official EPEVER weblloc.

Table of optional EPEVER accessories

A table detailing various optional accessories for EPEVER solar charge controllers, including remote temperature sensors, USB to RS485 cables, remote meters, WiFi/Bluetooth adapters, and data loggers, along with their functions.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.