The Lithonia Lighting Quantum ELM2L M12 is a contemporary LED emergency light designed to provide reliable illumination during power outages. This unit features two adjustable LED lamp heads, delivering a combined 220 lumens for effective light distribution in various commercial and industrial settings.
Les característiques clau inclouen:
- 90 Minutes of Illumination: Provides emergency lighting for 90 minutes upon power loss.
- Aimable LED Lamp Caps: Two 1.2W white LED lamp heads with a 10-year typical lifespan, offering 220 total lumens.
- Construcció duradora: Flame-rated 5VA thermoplastic housing, impact-resistant white casing.
- Integrated Test Switch: Features an integrated test switch and bi-color LED status indicator for easy system checks.
- Maintenance-Free Battery: Rechargeable nickel-cadmium battery requires no maintenance.
- Fàcil instal·lació: Designed for surface mounting on walls or ceilings, fitting standard junction boxes.
- Dual Voltage: Compatible with 120/277V electrical systems.
- Compliment: UL listed, meets UL 924, NFPA 101, NEC, Title 20, and OSHA standards.

2. Informació de seguretat
Read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or other hazards, which could cause property damage, personal injury, or death.
- Seguretat elèctrica: All wiring should be performed by a qualified electrician in accordance with national and local electrical codes. Ensure power is disconnected at the circuit breaker before installation or servicing.
- Ús del producte: This product is intended for indoor damp locations (50°F to 104°F / 10°C to 40°C). Do not use in hazardous locations or with dimmers.
- Seguretat de la bateria: The unit contains a nickel-cadmium battery. Dispose of batteries properly according to local regulations.
- Advertència de la proposta 65: Aquest producte pot contenir productes químics coneguts a l’Estat de Califòrnia per causar càncer i defectes congènits o altres danys reproductius.
3. Contingut del paquet
Verifiqueu que tots els components estiguin presents i no estiguin danyats en obrir l'envàs:
- Lithonia Lighting Quantum ELM2L M12 Emergency Light Fixture
- Maquinari de muntatge (cargols, femelles de cable)
- Manual d'instruccions
4. Instal·lació
The ELM2L M12 is designed for easy surface mounting on walls or ceilings. The back plate is compatible with most standard junction boxes.
4.1 Passos de muntatge
- Desconnecteu l'alimentació: Desconnecteu l'alimentació a l'interruptor automàtic abans de començar la instal·lació.
- Remove Back Assembly: Carefully remove the back assembly from the main body of the fixture.
- Connecteu el cablejat: Hold the back plate up to the junction box. Use wire nuts to connect the fixture wires to the junction wires: green to green (ground), black to black, and white to white.
- Placa posterior segura: Push excess wires into the junction box. Align the keyholes on the back of the fixture housing with the junction box screw holes. Lift the fixture up, install screws, and tighten them to secure the housing assembly to the wall or ceiling.
- Connecta la bateria: Within the main housing, connect the battery plug to the charger board. Ensure the battery cable is routed to avoid interference with the AC input connector or other components. The plug-and-play design allows for easy replacement of components.
- Re-install Main Body: Re-install the main body of the fixture onto the secured back plate.
- Restaura l'alimentació: Turn on electricity at the circuit breaker.


4.2 Vídeo d'instal·lació
5. Instruccions de funcionament
Once installed and power is restored, the emergency light will begin charging its internal battery. The bi-color LED status indicator will show the charging status.
5.1 Manual Testing
The unit is equipped with a manual test switch. Press and hold the test button to initiate a manual test. The LED lamp heads should illuminate, indicating that the battery backup system is functional. Release the button to return to normal operation.
Regular testing is crucial to ensure the unit operates correctly during an emergency. Refer to local codes for recommended testing frequency (e.g., monthly 30-second tests, annual 90-minute discharge tests).
6. Manteniment
The ELM2L M12 emergency light is designed for minimal maintenance. The nickel-cadmium battery is maintenance-free.
- Neteja: Periodically clean the exterior of the fixture with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Substitució de la bateria: While designed for a long lifespan, batteries may eventually require replacement. The plug-and-play design facilitates easy battery replacement by a qualified technician.
- Lamp Ajust del cap: The two LED lamp heads are aimable. Adjust them as needed to direct light to the required egress path.
7. Solució De Problemes
If the emergency light is not functioning as expected, refer to the following common issues and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| Unit does not illuminate during power outage or test. | No AC power; Battery not connected or faulty; Battery not charged. | Check circuit breaker. Ensure battery is properly connected. Allow 24 hours for initial charge. Replace battery if necessary. |
| LED indicator is off or red. | No AC power; Battery fault; Charger fault. | Check AC power. Perform battery test. If issue persists, contact customer support. |
| Emergency lights dim quickly. | Bateria no completament carregada; bateria a punt d'arribar al final de la seva vida útil. | Ensure unit is connected to continuous AC power. Replace battery if it fails to hold a charge. |
8. Especificacions
| Característica | Detall |
|---|---|
| Número de model | ELM2L M12 |
| Marca | Il·luminació Lithonia |
| Dimensions (L x A x A) | 9.72" x 3.10" x 4.68" |
| Pes | 1.31 lliures |
| Color | Blanc |
| Material | Termoplàstic |
| Font de llum | LED (2 aimable lamp caps) |
| Brillantor | 220 lúmens (total) |
| Wattage | 2.4 watts |
| Voltage | 120/277V Volum dualtage |
| Tipus de bateria | Nickel-Cadmium (maintenance-free) |
| Operació d’emergència | 90 minuts |
| Tipus de muntatge | Muntatge al sostre, muntatge a la paret |
| Temperatura de funcionament | De 50 °F a 104 °F (de 10 °C a 40 °C) |
| Certificacions | UL Listed, UL 924, NFPA 101, NEC, Title 20, OSHA |
9. Garantia i Suport
The Lithonia Lighting Quantum ELM2L M12 Emergency Light comes with a Garantia limitada del fabricant d'5 any. For warranty claims or technical support, please visit the official Lithonia Lighting weblloc o poseu-vos en contacte amb el seu servei d'atenció al client.
For more detailed product information and support resources, visit: lithonia.acuitybrands.com