DIGITEN DFC15 Controller (ZJ-DFC15-2)
DIGITEN DFC15 Flowmeter Controller User Manual
Model: DFC15 (ZJ-DFC15-2)
1. Introducció
The DIGITEN DFC15 is a versatile digital flowmeter controller designed for precise measurement and quantitative control of liquid flow rate and volume. It features a clear LCD display, adjustable accuracy, and temperature monitoring capabilities, making it suitable for various applications including water metering.
This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your DFC15 controller to ensure optimal performance and longevity.
2. Característiques clau
- Quantitative Control: Automatically shuts off the solenoid valve when the desired flow volume is reached.
- Flow Rate Monitoring: Displays real-time liquid volume passing per minute.
- Compatibilitat universal: Works with various hall effect flow sensors by adjusting the K value.
- Volume Unit Selection: Displays measurements in Liters or Gallons.
- Water Meter Functionality: Can be used to measure total water volume.
- Adjustable Accuracy: Calibrate accuracy via the K parameter.
- Monitor de temperatura: Includes a temperature sensor for liquid temperature measurement.
- Easy-to-Read LCD: Clear display of total volume, flow rate, and temperature with custom icons for status indication.
3. Especificacions tècniques
| Paràmetre | Valor |
|---|---|
| Requisit d'alimentació del controlador | 12VDC |
| Entrada de l'adaptador de corrent | 100-240VAC |
| Sortida de l'adaptador de corrent | 12VDC, màxim 2A |
| Precisió de mesura | ±1% |
| Output for Solenoid Valve | 12VDC, màxim 2A |
| Interval del sensor de temperatura | 0-100 °C / 32-212 °F |
| Precisió del sensor de temperatura | ±1°C / ±1°F (NTC3950, M8 thread) |
| Volum total màxim | 999999 G/L |
| Interval quantitatiu | 0-9999 G/L |
| Interval de cabal | 0-9999.99 L/min (GPM) |
| Longitud del cable | 1m |
| Dimensions | 88 mm x 126 mm x 30 mm (3.46 x 4.96 x 1.18 polzades) |
| Pes | 200 g (0.01 unces) |
| Temperatura de l'entorn de funcionament | 0-50 °C / 32-122 °F |
| Ambient de funcionament Humitat | <85% Relative Humidity |
4. Contingut del paquet
En obrir el paquet, comproveu que tots els components siguin presents i no estiguin danyats:
- 1 x DFC15 Controller
- 1 x adaptador de corrent
- 1 x Manual d'instruccions (aquest document)

Image: Contents of the DFC15 package, showing the controller, power adapter, and associated cables/sensors.
5. Configuració i instal·lació
Proper installation is crucial for the accurate and safe operation of the DFC15 controller. Follow these steps carefully:
5.1. Identificació de components

Imatge: Frontal view of the DFC15 controller, highlighting the display and control buttons.
Familiarize yourself with the controller's interface:
- Visualització: Shows quantitative value, flow rate, temperature, and status icons.
- Botó MENÚ: Accesses settings and configuration options.
- Botó SET: Confirms selections and enters edit mode.
- Botó ESBORRA: Clears current readings or exits a menu.
- Fletxes amunt/avall: Navega pels menús i ajusta els valors.
- RUN/STOP Button: Initiates or halts the flow control process.
- RUN/STOP Indicators: LEDs indicating operational status.
5.2. Esquema de cablejat
The DFC15 controller connects to a flow sensor, a temperature sensor, and an optional solenoid valve. Refer to the diagram below for correct wiring:

Image: Detailed wiring diagram showing connections for the DFC15 controller, flow sensor, temperature sensor, and solenoid valve.
- Connect the flow sensor to the designated input on the controller. Ensure the flow direction matches the sensor's arrow.
- Connect the temperature sensor to its dedicated port. The M8 thread sensor should be installed in a suitable fitting in the liquid path.
- If using quantitative control, connect the 12VDC solenoid valve to the controller's output terminals. Observe polarity.
- Connect the provided 12VDC power adapter to the controller's power input.
Note: Ensure all connections are secure before applying power.
5.3. Muntatge del controlador
The controller can be mounted using the integrated eyelet on the back. Choose a location that is dry, stable, and allows for easy viewing of the display and access to buttons.

Imatge: Part posterior view of the DFC15 controller, showing the label with model and power information, and the mounting eyelet.
6. Instruccions de funcionament
6.1. Power On and Initial Display
Once powered on, the DFC15 will display the current total volume, real-time flow rate, and temperature. The default units are Liters (L) and Liters Per Minute (LPM).

Imatge: Anglesa view of the DFC15 controller, showing the illuminated digital display with various readings.
6.2. Setting Quantitative Control (Batch Mode)
- Premeu el botó MENÚ botó per entrar al menú de configuració.
- Navigate using the Up/Down arrows to find the "Quantitative Setting" or similar option.
- Premeu SET to enter the quantitative value adjustment.
- Use the Up/Down arrows to set your desired volume (e.g., 50 Liters). Press SET to confirm each digit.
- Once the value is set, press MENÚ per sortir de la configuració.
- To start the quantitative dispense, press the CARRER/PARAR button. The controller will activate the solenoid valve and stop when the set volume is reached.
- To stop a dispense manually, press the CARRER/PARAR botó de nou.
6.3. Adjusting K-Value (Calibration)
The K-value is a calibration factor that allows the controller to accurately measure flow from different sensors. This value may need adjustment for precise readings.
- Premeu el botó MENÚ botó.
- Navigate to the "K-Value Setting" or "Calibration" option.
- Premeu SET to adjust the K-value.
- Use the Up/Down arrows to change the value. A higher K-value means the sensor is reporting more pulses per unit of volume.
- To calibrate, dispense a known volume of liquid (e.g., 10 liters) and compare it to the controller's reading. Adjust the K-value until the controller's reading matches the actual dispensed volume.
- Premeu SET to confirm the new K-value, then MENÚ per sortir.
Tip: Start with the default K-value or a value provided with your flow sensor. Fine-tune as needed.
6.4. Changing Units (Liters/Gallons, Celsius/Fahrenheit)
The DFC15 allows you to switch between different measurement units.
- Volume/Flow Rate Units: Access the "Unit Setting" in the MENÚ to toggle between Liters (L) and Gallons (G) for total volume and LPM/GPM for flow rate.
- Unitats de temperatura: The temperature display can be switched between Celsius (°C) and Fahrenheit (°F) via a setting in the MENÚ.
6.5. Resetting Total Volume
To clear the accumulated total volume, press the CLAR button. Confirm the reset if prompted.
7. Manteniment
Regular maintenance ensures the longevity and accuracy of your DFC15 controller and associated sensors.
- Neteja: Wipe the controller's display and casinNetegeu amb un drap suau i sec. Eviteu productes de neteja o dissolvents abrasius.
- Inspecció del sensor: Periodically check the flow sensor and temperature sensor for any debris, blockages, or damage. Clean as necessary according to the sensor manufacturer's instructions.
- Comprovació de la connexió: Assegureu-vos que totes les connexions elèctriques estiguin ben fixades i lliures de corrosió.
- Recalibració: If you suspect inaccuracies or after significant changes in your system (e.g., replacing a sensor), perform a K-value recalibration as described in Section 6.3.
- Emmagatzematge: If storing the unit for an extended period, disconnect power and store in a dry, cool environment.
8. Solució De Problemes
This section addresses common issues you might encounter with your DFC15 controller.
| Problema | Causa possible | Solució |
|---|---|---|
| El controlador no s'encén. | Sense corrent, adaptador defectuós, connexió fluixa. | Check power outlet. Ensure power adapter is correctly connected. Test adapter if possible. |
| Flow rate/volume display is 0 or inaccurate. | Flow sensor not connected, faulty sensor, K-value incorrect, no flow. | Verify flow sensor connection. Check for blockages in the flow path. Recalibrate K-value (Section 6.3). Ensure liquid is flowing. |
| Solenoid valve does not open/close. | Incorrect wiring, faulty valve, quantitative setting not enabled. | Check solenoid valve wiring and polarity. Ensure quantitative control is set and activated. Test valve independently if possible. |
| La lectura de temperatura és incorrecta. | Temperature sensor not connected, faulty sensor, sensor not immersed. | Verify temperature sensor connection. Ensure sensor is properly installed in the liquid. |
| Display backlight turns off too quickly. | Configuració per defecte. | This is a power-saving feature. There may be a setting in the menu to adjust backlight timeout, consult the full user manual (PDF) if available. |
If the problem persists after attempting these solutions, please contact DIGITEN customer support.
9. Garantia i Suport
DIGITEN provides a one-year warranty for any problems with the DFC15 controller. For technical support, warranty claims, or further assistance, please contact DIGITEN customer service through the official channels where you purchased the product or visit the DIGITEN Store on Amazon.
També podeu consultar l'oficial Manual d'usuari (PDF) per a informació més detallada.