CEM DT-172

CEM DT-172 Temperature and Humidity Data Logger User Manual

Model: DT-172

1. Introducció

The CEM DT-172 is a temperature and humidity data logger designed for efficient and convenient long-term environmental monitoring. This device records temperature and humidity values, storing them internally for later retrieval and analysis via a personal computer with a USB interface. This manual provides essential information for the proper setup, operation, and maintenance of your DT-172 data logger.

2. Informació de seguretat

Si us plau, llegiu i comprengui les següents precaucions de seguretat abans d'utilitzar el dispositiu:

  • Read all instructions thoroughly before operating the device.
  • Do not expose the device to extreme temperatures or humidity levels outside its specified operating range.
  • Do not attempt to open, disassemble, or modify the device. This may void the warranty and cause damage.
  • Dispose of depleted batteries according to local environmental regulations.
  • Mantingueu el dispositiu allunyat de camps electromagnètics forts.

3. Producte acabatview

The CEM DT-172 features a compact design with an LCD display and two control buttons. It is equipped with internal sensors for accurate temperature and humidity measurement.

3.1 Característiques clau

  • Memory capacity for 32,000 readings (16,000 each for temperature and humidity).
  • LCD display provides real-time data and logging status.
  • User-selectable measurement cycle from 1 second to 24 hours.
  • Extended battery life, typically more than 3 years.
  • USB interface for convenient data download to a PC.
  • Alarm display indicates when user-defined maximum or minimum values are exceeded.
  • Includes analysis software for data graphing, review, and export.
  • Supports temperature measurement in both Celsius (°C) and Fahrenheit (°F).
  • High resolution: 0.1°C and 0.1% RH.

3.2 Components

El paquet estàndard inclou:

  • DT-172 Data Logger Unit
  • Manual d'instruccions
  • 3.6V Lithium battery (14250 type) (Note: Batteries are not included in some packages and must be purchased separately)
  • Programari CD
  • Cable USB
  • Suport de paret
  • Instrument Lock
CEM DT-172 Data Logger with highlighted features: Wide Range, Relative Humidity, Resolution, LED, USB, 16000 Data Memory.

Figure 1: CEM DT-172 Data Logger highlighting key features and display.

CEM DT-172 Data Logger with included accessories: USB cable, 3.6V Lithium battery, and instrument lock.

Figure 2: CEM DT-172 Data Logger with its accessories.

4. Configuració

4.1 Instal·lació de la bateria

  1. Locate the battery compartment on the back of the DT-172 device.
  2. Obriu la tapa del compartiment de la bateria.
  3. Insert one 3.6V Lithium battery (14250 type) into the compartment, ensuring correct polarity.
  4. Tanqueu de manera segura la tapa del compartiment de la bateria.

Nota: Batteries are typically not included and must be purchased separately.

4.2 Instal·lació del programari

  1. Inseriu el CD de programari proporcionat a la unitat de CD-ROM de l'ordinador.
  2. Follow the on-screen instructions to install the analysis software. The software is compatible with Windows 98/2000/XP/Vista/7 operating systems.

4.3 Initial Connection to PC

  1. Connect the data logger to your computer using the supplied USB cable.
  2. Your computer should automatically detect the device and install any necessary drivers.
Hand holding CEM DT-172 Data Logger connected to a laptop via USB cable.

Figure 3: Connecting the DT-172 Data Logger to a PC via USB.

5. Instruccions de funcionament

5.1 Encès/Apagat

The device typically powers on automatically upon correct battery installation. There is no explicit power button.

5.2 Mostra informació

The LCD displays current temperature, humidity, time, and logging status. Two LEDs, labeled ALM (Alarm) and REC (Recording), indicate the device's status.

Primer pla view of the CEM DT-172 Data Logger's LCD display showing temperature, time, and buttons.

Figure 4: Close-up of the DT-172 display and control buttons.

5.3 Funcions dels botons

  • Temp. %RH Button: Press this button to cycle between displaying the current temperature and relative humidity readings on the LCD.
  • Botó MAX/MIN: Premeu aquest botó per view the maximum and minimum recorded temperature and humidity values since the last reset or logging session.

5.4 Inici del registre de dades

  1. Connect the data logger to your PC and open the analysis software.
  2. Use the software to configure desired logging parameters, such as the measurement cycle (e.g., 1 second, 1 hour, 24 hours) and any alarm limits for temperature and humidity.
  3. Once configured, disconnect the logger from the PC. The device will automatically begin standalone data logging. The REC LED will illuminate to indicate active recording.

5.5 Descàrrega de dades

  1. To retrieve recorded data, connect the data logger to your PC via the USB cable.
  2. Open the analysis software on your computer.
  3. Follow the software's instructions to download the logged data from the device.
  4. El programari et permet view the data in graphical format, analyze trends, and export the data for further processing.

6. Manteniment

6.1 Substitució de la bateria

When the battery indicator on the LCD shows low power, replace the 3.6V Lithium battery (14250 type) promptly to ensure continuous operation and prevent data loss. Refer to Section 4.1 for battery installation steps.

6.2 Neteja

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water. Ensure the sensor area remains clean and free of dust or obstructions for accurate readings.

7. Solució De Problemes

  • El dispositiu no s'encén: Check if the 3.6V Lithium battery (14250) is correctly installed and not depleted. Ensure proper polarity.
  • No data logging: Verify that logging parameters have been set and activated via the analysis software. Confirm the REC LED is illuminated when the device is disconnected from the PC. Ensure sufficient memory is available (32,000 readings capacity).
  • Cannot connect to PC or download data: Ensure the USB cable is securely connected to both the logger and the PC. Verify that the analysis software is correctly installed. Try connecting to a different USB port on your computer.
  • Alarm indication (ALM LED): El ALM LED indicates that user-defined maximum or minimum temperature/humidity values have been exceeded. Review your logged data using the software to identify the specific exceedance.
  • Inaccurate RH readings at low humidity: Some users have reported limitations in logging data for relative humidity below 18% RH. This may be a characteristic of the device's sensor.

8. Especificacions

ParàmetreValor
Interval de temperatura-40 a 70 °C (-40 a 158 °F)
Precisió de la temperatura±1 °C
Gamma d’humitat0 a 100% HR
Precisió de la humitat±3.5% HR
Capacitat de memòria32,000 readings (16,000 for Temp, 16,000 for RH)
Taxa de mesura1 second to 24 hours (selectable)
Resolució0.1 °C, 0.1% HR
Durada de la bateriaNormalment 3 anys
Font d'alimentació1 x 3.6V Lithium battery (14250)
Programari d'anàlisiWindows 98/2000/XP/Vista/7 compatible
Dimensions (AxAxP)94mm x 50mm x 32mm (approx. 9.4cm x 5cm x 3.2cm)
Pes91 g
Tipus de muntatgeMuntatge de paret
Número de modelDT-172
UPC736631254849
CEM DT-172 Data Logger with dimensions indicated as 5cm width and 9.4cm height.

Figure 5: DT-172 Data Logger with approximate dimensions.

9. Informació de la garantia

Warranty details for the CEM DT-172 Temperature and Humidity Data Logger are not specified in the provided product information. Please refer to your purchase documentation or contact the manufacturer directly for specific warranty terms and conditions.

10. Atenció al client

For technical assistance, inquiries, or support regarding your CEM DT-172 Data Logger, please contact CEM Instruments (India) Pvt. Ltd. using the information below:

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.