This manual provides essential information for the safe and effective use of your Homend Automatic Water Pump Pressure Controller. Please read this manual thoroughly before installation and operation, and keep it for future reference.

The Homend Automatic Water Pump Pressure Controller is designed to automate the operation of water pumps. It automatically stops the pump if no water is detected, eliminating the need for a pressure tank. It controls the pump's on and off cycles based on water pressure changes, contributing to water conservation. This controller is suitable for various pump types including self-priming pumps, jet pumps, garden pumps, clarified water pumps, and centrifugal pumps.

Homend Automatic Water Pump Pressure Controller

Figure 1: Homend Automatic Water Pump Pressure Controller

Aquesta imatge mostra el principal view of the Homend Automatic Water Pump Pressure Controller, featuring its distinctive yellow and blue casing with a pressure gauge visible on the side.

Informació de seguretat

Observeu sempre les precaucions de seguretat bàsiques per reduir el risc d'incendi, descàrrega elèctrica i lesions personals.

  • Ensure the power supply matches the controller's voltage (110 V).
  • Desconnecteu l'alimentació abans de realitzar qualsevol instal·lació, manteniment o resolució de problemes.
  • Si no esteu segurs, la instal·lació l'ha de dur a terme un professional qualificat.
  • Do not operate the controller if it is damaged.
  • Keep the controller away from excessive moisture or direct water spray unless properly sealed for such conditions.

Producte acabatview

Familiarize yourself with the components of the pressure controller.

Labeled components of the Homend Automatic Water Pump Pressure Controller

Figure 2: Controller Components and Indicators

Aquesta imatge mostra la part superior view of the controller with key components labeled: Power on Indicator, Pump on Indicator, Failure Indicator, Restart Button, Connect Power Supply, Connect Water Pump, and Water Inlet (G1").

  • Power on Indicator: Illuminates when the unit is receiving power.
  • Pump on Indicator: Illuminates when the water pump is actively running.
  • Indicador de fallada: Illuminates to indicate an error or fault condition, such as dry running.
  • Botó de reinici: Used to manually restart the pump after a failure or power interruption.
  • Connecteu la font d'alimentació: Terminal for connecting the main power input.
  • Connectar la bomba d'aigua: Terminal for connecting the water pump's power cable.
  • Water Inlet (G1"): The primary water connection point for the controller.

Configuració i instal·lació

Follow these steps for proper installation of the water pump pressure controller.

  1. Muntatge: Securely mount the controller in a suitable location, ensuring it is protected from direct weather exposure if not rated for outdoor use.
  2. Connexió d'aigua: Connect the water inlet (G1") of the controller to your water supply line. Ensure all connections are watertight.
  3. Connexió de la bomba: Connect the water pump's outlet to the controller's water outlet.
  4. Electrical Connection (Power Supply): Connect the main 110V power supply to the 'Connect Power Supply' terminals on the controller. Ensure correct wiring for live, neutral, and ground (if applicable).
  5. Electrical Connection (Water Pump): Connect the water pump's power cable to the 'Connect Water Pump' terminals on the controller.
  6. Emplenament inicial: Before powering on, ensure the pump and suction line are primed with water to prevent dry running.
Examples of Homend Automatic Water Pump Pressure Controller installations

Figure 3: Typical Installation Scenarios

This image illustrates various application examples, showing the controller integrated into different water pump systems, demonstrating its versatility in home and garden setups.

Close-up of electrical connections on the Homend Automatic Water Pump Pressure Controller

Figure 4: Electrical Connection Points

Un detallat view of the electrical connection points on the controller, showing the secure cable glands for power input and pump output.

Instruccions de funcionament

The controller is designed for fully automatic operation.

  1. Encès: Once installed and connected, apply power to the controller. The 'Power on Indicator' LED will illuminate.
  2. Funcionament automàtic: The controller will automatically detect water pressure changes. When water is demanded (e.g., a tap is opened), the pressure drops, and the controller will activate the pump. The 'Pump on Indicator' LED will illuminate.
  3. Pump Off: When water demand ceases and pressure is restored, the controller will automatically turn off the pump. The 'Pump on Indicator' LED will turn off.
  4. Protecció de funcionament en sec: If the water supply to the pump runs out, the controller will automatically stop the pump to prevent damage. The 'Failure Indicator' LED will illuminate.
  5. Restarting After Failure: If the 'Failure Indicator' is lit due to dry running, ensure the water supply is restored. Then, press the 'Restart Button' to reset the controller and resume pump operation.

Manteniment

Regular maintenance ensures optimal performance and longevity of your controller.

  • Inspecció periòdica: Periodically check all electrical and water connections for leaks, corrosion, or loose wiring.
  • Neteja: Mantingueu l'exterior del controlador net i lliure de pols i restes. Feu servir un drap suau i sec. No utilitzeu productes de neteja abrasius ni dissolvents.
  • Hivernització: In cold climates, ensure the controller and associated plumbing are protected from freezing temperatures to prevent damage.
  • Pressure Gauge Check: Monitor the pressure gauge for consistent readings during operation.

Resolució de problemes

Consulteu aquesta secció per conèixer els problemes comuns i les seves solucions.

ProblemaCausa possibleSolució
La bomba no arrenca.Sense font d'alimentació.
'Failure Indicator' is on (dry running).
Connexions elèctriques soltes.
Comproveu la font d'alimentació i l'interruptor.
Restore water supply and press 'Restart Button'.
Check and tighten all wiring connections (ensure power is off first).
La bomba funciona contínuament.Water leak in the system.
Mal funcionament del controlador.
Inspect plumbing for leaks and repair.
Contact customer support if no leaks are found.
La bomba s'encén i s'apaga amb freqüència.Small leak in the system.
Subministrament d'aigua insuficient.
Check for minor leaks.
Ensure adequate water flow to the pump.
'Failure Indicator' is on.No water in the pump/supply line (dry running).Ensure water supply is available and pump is primed. Press 'Restart Button'.

Especificacions

Key technical specifications for the Homend Automatic Water Pump Pressure Controller.

Dimensions of the Homend Automatic Water Pump Pressure Controller

Figura 5: Dimensions del producte

This image provides the key dimensions of the controller, showing a height of 7.09 inches and a width of 4.13 inches.

CaracterísticaEspecificació
MarcaHomend
ModelAutomatic Water Pump Pressure Controller
Voltage110 V
Freqüència50-60 Hz
Corrent màxima10A
Potència màxima1.1KW
Pressió màxima de treball10 Bar (1 MPa)
Connexió1" Male
MaterialPlàstic
Colorgroc
Dimensions del producte (L x A x A)0.79" x 0.79" x 0.79" (Note: This appears to be a generic placeholder, actual dimensions from image are approx. 4.13" W x 7.09" H)
Pes de l'article2.46 lliures
UPC711221778127

Garantia i Suport

For warranty information, please refer to the documentation included with your purchase or contact the seller directly. This product includes a manual instruction in the package.

For technical support or inquiries, please contact Homend customer service through the retailer where the product was purchased.

© 2025 Homend. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.