BUCHER M-3551-0501

Bucher Double-Acting Hydraulic Pump Assembly User Manual

Model: M-3551-0501 | Brand: BUCHER

Introducció

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Bucher Double-Acting Hydraulic Pump Assembly. This unit is designed to replace worn-out double-acting hydraulic systems on dump trailers, dump beds, BWISE & BRIMAR dump trailers, Tilt-Bed Trailers, and Hydraulic jacks. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures.

Característiques clau

  • Double Acting Hydraulic Pump Assembly: Provides both power up and power down functionality.
  • Pressió màxima de funcionament: Capable of reaching 3200 psi.
  • Caudal: Delivers 2 Gallons per Minute (GPM) at a nominal 1000 psi.
  • Comandament a distància: Includes a 25-foot corded remote for convenient operation.
  • Capacitat de l'embassament: Equipped with a 1.5 Gallon reservoir.
  • Voltage: Operates on 12 Volts DC.

Components acabatsview

Familiarize yourself with the main components of your hydraulic pump assembly.

Bucher Double-Acting Hydraulic Pump Assembly with reservoir and remote

Figura 1: Complete Bucher Double-Acting Hydraulic Pump Assembly, showing the motor, pump, 1.5-gallon reservoir, hydraulic lines, and the yellow corded remote control unit.

Close-up of Bucher Hydraulics label on reservoir

Figura 2: Primer pla view of the product label located on the reservoir, displaying the "BUCHER hydraulics" logo and the model number M-3551-0501, along with serial number and manufacturing details.

Close-up of hydraulic pump motor label

Figura 3: Detallada view of the electric motor component of the hydraulic pump, showing its label with "BUCHER hydraulics" and electrical specifications, including the 12 Volts DC rating.

Wiring connections on the hydraulic pump assembly

Figura 4: View of the electrical wiring connections on the hydraulic pump assembly, including the solenoid and various terminals for power input and remote control connection.

Hand holding the corded remote control for the hydraulic pump

Figura 5: A hand demonstrating the use of the yellow corded remote control, highlighting the "UP" and "DOWN" buttons for operating the hydraulic pump's double-acting functionality.

Configuració i instal·lació

Proper installation is crucial for the safe and efficient operation of your hydraulic pump assembly. If you are unsure about any steps, consult a qualified professional.

1. Muntatge

Securely mount the hydraulic pump assembly to a stable and level surface. Ensure adequate clearance for maintenance and ventilation. Refer to the product dimensions (16 x 8 x 9 inches) for space planning.

2. Connexions elèctriques

This unit operates on 12 Volts DC. Connect the pump to a suitable 12V power source, ensuring correct polarity. Use appropriate gauge wiring for the current draw. The included corded remote connects to the designated terminals on the pump unit.

Hydraulic pump schematic and wiring diagram

Figura 6: Detailed schematic diagram of the hydraulic pump system, including hydraulic flow paths, electrical wiring connections, and component identification. This diagram is essential for correct installation and troubleshooting.

Important: Always disconnect power before making any electrical connections. Consult the wiring diagram (Figure 6) for precise connection points.

3. Connexions hidràuliques

Connect your hydraulic cylinders or actuators to the appropriate outlet ports on the pump. Ensure all connections are tight and free of leaks. This is a double-acting pump, meaning it provides pressure for both extension and retraction of the cylinder.

4. Reservoir Filling

Fill the 1.5 Gallon reservoir with the recommended hydraulic fluid. Do not overfill. Ensure the breather cap is properly installed after filling. The unit is designed for outside usage.

Instruccions de funcionament

The Bucher Double-Acting Hydraulic Pump Assembly is operated using the included 25-foot corded remote control.

Power Up/Power Down Operation

  1. Ensure all hydraulic and electrical connections are secure and the reservoir is filled to the correct level.
  2. To extend your hydraulic cylinder (power up), press and hold the "AMUNT" button on the remote control. The pump will activate, and the cylinder will extend.
  3. To retract your hydraulic cylinder (power down), press and hold the "BAIX" button on the remote control. The pump will activate, and the cylinder will retract.
  4. Release the button to stop the hydraulic action.

Nota: The pump is designed for intermittent duty. Avoid continuous operation for extended periods to prevent overheating.

Manteniment

Regular maintenance ensures the longevity and optimal performance of your hydraulic pump assembly.

1. Hydraulic Fluid Level Check

Periodically check the hydraulic fluid level in the 1.5 Gallon reservoir. Top up with the recommended hydraulic fluid if necessary. Low fluid levels can cause pump damage and poor performance.

2. Fluid Replacement

Replace the hydraulic fluid according to the manufacturer's recommendations or if it appears discolored or contaminated. Proper disposal of used hydraulic fluid is essential.

3. Electrical Connections Inspection

Regularly inspect all electrical connections for corrosion, looseness, or damage. Ensure all terminals are clean and secure.

4. Neteja general

Keep the exterior of the pump assembly clean and free from dirt, debris, and excessive moisture. This helps prevent corrosion and ensures proper heat dissipation.

Resolució de problemes

Aquesta secció ofereix solucions a problemes comuns que podeu trobar. Per a problemes que no figuren aquí, poseu-vos en contacte amb l'atenció al client.

ProblemaCausa possibleSolució
Pump does not operate when remote button is pressed.No power supply; Loose electrical connections; Faulty remote; Blown fuse/breaker.Check 12V power source; Inspect all wiring connections; Test remote continuity; Check and replace fuse/reset breaker.
Low hydraulic pressure or slow operation.Low hydraulic fluid level; Air in the system; Clogged filter (if applicable); Worn pump components.Check and top up fluid; Bleed air from system; Inspect/replace filter; Contact service for pump inspection.
Hydraulic fluid leaks.Loose fittings; Damaged seals or hoses.Tighten all hydraulic fittings; Inspect and replace damaged seals or hoses.
Pump motor runs but no hydraulic action.Low fluid; Air in system; Malfunctioning valve.Check fluid level; Bleed air; Inspect and test hydraulic valves.

Especificacions

AtributDetall
FabricantBUCHER HYDRAULICS
Número de partM-3551-0501
Número de model de l'articleM-3551-0501
Pes de l'article30 lliures
Dimensions del producte16 x 8 x 9 polzades
MaterialAlumini, plàstic
Voltage12 Volts
Quantitat de paquet d'articles1
Caudal2 Gallons Per Minute (at Nominal 1000 psi)
Pressió màxima de funcionament3200 psi
ÚsFora
Components inclososCorded Remote, Power Unit, Reservoir

Informació de la garantia

Specific warranty details for the Bucher Double-Acting Hydraulic Pump Assembly are not provided in the available product data. For information regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact BUCHER HYDRAULICS directly.

Atenció al client

For technical assistance, troubleshooting beyond this manual, or inquiries about parts and service, please contact the manufacturer, BUCHER HYDRAULICS, or the seller from whom you purchased this product. Contact information is typically available on the manufacturer's official weblloc web o el vostre rebut de compra.

© 2024 BUCHER HYDRAULICS. All rights reserved.

Aquest manual està subjecte a canvis sense previ avís.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.