TORCHSTAR ZF3EL-DHS-4P

TORCHSTAR LED Emergency Lighting Instruction Manual

Model: ZF3EL-DHS-4P

Brand: TORCHSTAR

1. Introducció

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your TORCHSTAR LED Emergency Lighting fixture. This commercial-grade emergency light features a built-in battery backup, two adjustable square heads, and is UL Listed for safety and performance. It is designed to provide reliable illumination during power outages in various commercial and residential settings.

TORCHSTAR LED Emergency Lighting fixture with two adjustable heads

Image 1.1: The TORCHSTAR LED Emergency Lighting fixture.

Característiques principals:

  • Còpia de seguretat de la bateria: Complies with UL 924 regulations, providing over 90 minutes of continuous lighting during power failures with its 3.6V 1000mAh rechargeable battery.
  • Disseny de doble capçal: Features two square heads with 12 high-grade LED chips each, delivering ultra-bright 6000K pure white light.
  • Voltage Compatibilitat: Supports AC 120V for general household lighting and AC 277V for commercial or industrial applications.
  • Fàcil instal·lació: Designed for surface mounting via a back plate, with all necessary hardware included.
  • Construcció duradora: Made with impact-resistant thermoplastic housing.

2. Què hi ha a la caixa

Verifiqueu que tots els components siguin presents abans de començar la instal·lació.

  • TORCHSTAR LED Emergency Lighting Fixture
  • Maquinari de muntatge (cargols, femelles, etc.)
  • Manual d'instruccions
Interna view of the emergency light showing LED heads, battery, and circuit board

Image 2.1: Internal components including LED heads, battery, and test button.

3. Configuració i instal·lació

This emergency light is designed for hardwired surface mounting. Ensure power is OFF at the circuit breaker before installation.

3.1 Activació inicial

Before connecting to the main power source, the internal battery must be connected. The battery is disconnected during shipping to prevent drain.

  1. Carefully remove the front cover plate of the fixture.
  2. Locate the internal battery and its connector. Connect the battery to the circuit board.
  3. Replace the cover plate, ensuring it is securely fastened.

Video 3.1: Detailed instructions for wiring and setting up the LED Emergency Light.

This video demonstrates the unboxing, battery connection, and initial power-up sequence for the emergency light. It shows how to connect the internal battery to prevent battery drain during storage and how to test the light's functionality once connected to a power source.

3.2 Muntatge de l'aparell

The fixture is designed for surface mounting. Use the provided mounting hardware.

  1. Fix the back plate securely to the junction box (J-box) on the wall or ceiling.
  2. Connect the electrical wires (live, neutral, ground) from the J-box to the corresponding wires on the fixture using the provided wire nuts. Ensure correct voltage (120V or 277V) is applied.
  3. Secure the light body back to the mounted back plate, ensuring it clicks into place.
Three-step installation guide showing removal of cover, wire connection, and securing the light body

Image 3.2: Step-by-step visual guide for hardwired installation.

4. Instruccions de funcionament

Once installed and connected to a live power source, the emergency light will operate automatically.

4.1 Funcionament normal

  • When main AC power is present, the light will remain off, and the internal battery will charge. A red 'READY' indicator light will illuminate to show it is charging or fully charged.
  • In the event of a power failure, the light will automatically switch on, powered by its internal battery, providing emergency illumination for over 90 minutes.
  • When AC power is restored, the light will automatically turn off and resume battery charging.

4.2 Testing the Light

A 'TEST' button is located on the fixture for manual testing.

  • Press and hold the 'TEST' button. The emergency lights should illuminate, indicating the battery and lamps són funcionals.
  • Release the 'TEST' button. The lights should turn off (if AC power is present).
  • Regularly test the unit (e.g., monthly) to ensure proper function.
Emergency light with UL Listed, 120/277V AC voltage, and -4°F to 104°F working temperature icons

Image 4.1: Product features including UL listing, voltage compatibility, and operating temperature.

5. Manteniment

Proper maintenance ensures the longevity and reliability of your emergency lighting fixture.

  • Neteja: Clean the exterior of the fixture and light heads periodically with a soft, damp tela. No utilitzeu netejadors abrasius ni dissolvents.
  • Cura de la bateria: The built-in rechargeable battery is designed for long life. If the unit is not connected to AC power for an extended period, the battery may drain. Allow at least 24 hours for the battery to fully charge after initial installation or after a prolonged power outage.
  • Prova anual: Conduct a 90-minute discharge test annually. Disconnect AC power to the unit and ensure it provides illumination for the full 90 minutes. If it fails, the battery may need replacement.

6. Solució De Problemes

If your emergency light is not functioning as expected, refer to the following common issues and solutions:

ProblemaCausa possibleSolució
El llum no s'encén durant l'apagadatage.Bateria no connectada o descarregada.Ensure battery is connected internally. Allow 24 hours for initial charge. If issue persists, battery may need replacement.
Red 'READY' indicator light is off.No AC power to the fixture.Check circuit breaker and wiring connections to ensure continuous AC power supply.
Light heads are dim or flicker.Low battery charge or aging battery.Allow battery to fully charge (24 hours). If problem continues, replace the battery.
Light does not turn off when AC power is restored.Faulty control circuit.Contacteu amb l'assistència al client per obtenir assistència.

7. Especificacions

EspecificacióDetall
Nom del modelIl·luminació LED d'emergència
Número de model de l'articleZF3EL-DHS-4P
MarcaTORCHSTAR
Wattage2.4W
Entrada VoltageCA 120V/277V
Voltage3.6V DC
Tipus de bateriaRechargeable (3.6V 1000mAh)
Emergency Illumination DurationMés de 90 minuts
Flux lluminós220 lúmens
Temperatura de color6000 Kelvin (Pure White)
MaterialAcrilonitril butadiè estirè (ABS)
Temperatura de funcionament32°F - 104°F (-4°F - 104°F mentioned in image)
Tipus d'instal·lacióSurface Mount (Hardwired)
CertificacionsLlistat UL
Dimensions del producte11.87 cm de llargada x 5.16 cm d'amplada x 2.31 cm d'alçada
Pes de l'article1.6 lliures
Diagram showing the dimensions of the emergency light fixture

Image 7.1: Product dimensions (11.87in L x 5.16in W x 2.31in H).

8. Garantia i Suport

This TORCHSTAR LED Emergency Lighting fixture comes with a 2 any de garantia, assegurant qualitat i fiabilitat.

For technical support, warranty claims, or any questions regarding your product, please refer to the contact information provided on the product packaging or the official TORCHSTAR weblloc.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.