Thank you for choosing the NEWACALOX Milligram Scale. This high-precision digital scale is designed for accurate measurements up to 100g with 0.001g sensitivity. Please read this manual thoroughly before use to ensure proper operation and to maximize the lifespan of your device.

Informació de seguretat

  • Handle the scale with care. Avoid dropping or subjecting it to strong impacts.
  • Do not overload the scale beyond its maximum capacity of 100g, as this may permanently damage the internal sensor.
  • Keep the scale in a dry and clean environment. Avoid extreme temperatures and humidity.
  • Do not use the scale near strong electromagnetic fields, which can affect accuracy.
  • Ensure the scale is placed on a stable, vibration-free surface during operation.

Contingut del paquet

El paquet inclou els articles següents:

  • NEWACALOX Milligram Scale
  • Pes de calibratge de 100 g
  • Pinces
  • Plastic Weighing Pan/Tray
  • Cable d'alimentació USB
  • 2 x piles AAA
  • Manual d'usuari (aquest document)
NEWACALOX Milligram Scale with included accessories: scale, calibration weight, tweezers, and weighing pan.

Image: NEWACALOX Milligram Scale and its accessories.

Producte acabatview

Familiarize yourself with the main components of your NEWACALOX Milligram Scale:

Diagram of NEWACALOX Milligram Scale showing labeled parts: Windscreen, Container, Round Weighing Surface, USB Port, LED Screen, On-off Key, 8 Weighing Unit Mmode Key, PCS Key, Tare Function Key, Tweezers, Calibration Weight.

Image: Labeled diagram of the NEWACALOX Milligram Scale.

  • On-off Key: Encén o apaga la bàscula.
  • M (Mode) Key: Changes weighing units (G, MG, OZ, OZT, DWT, CT, GN, TL).
  • P (PCS) Key: Activa la funció de recompte de peces.
  • T (Tare) Key: Resets the display to zero, allowing you to weigh items in a container.
  • Pantalla LED: Digital display for weight and function indicators.
  • Round Weighing Surface: Where items are placed for weighing.
  • Parabrisa: Transparent cover to protect the weighing surface from air currents, improving accuracy.
  • Port USB: For connecting to a USB power supply (not for recharging internal batteries).

Font d'alimentació

Your scale offers two convenient power options:

  • Piles AAA: Insert 2 AAA batteries into the battery compartment located on the underside of the scale.
  • Potència USB: Connect the scale to a USB power source using the provided USB cable. Note that the USB connection provides power directly and does not recharge the AAA batteries.
Image showing the two power supply modes for the scale: AAA batteries and USB port connection.

Image: Two power supply options: AAA batteries and USB.

Configuració i calibratge

Configuració inicial

  1. Place the scale on a hard, flat, and stable surface, away from vibrations or air currents.
  2. Ensure the windscreen is properly installed.
  3. Power on the scale using either AAA batteries or the USB cable.

Calibració

Calibration is essential for accurate measurements. Perform calibration regularly or if you suspect inaccuracies.

  1. Turn the scale ON. Wait for the display to show "0.000g".
  2. Press and hold the "M" (Mode) key until "CAL" appears on the display, then release.
  3. Press the "M" key again. The display will flash the required calibration weight (e.g., "100.000g").
  4. Gently place the provided 100g calibration weight onto the center of the weighing surface.
  5. Wait for the display to show "PASS" and then return to "0.000g". This indicates successful calibration.
  6. Traieu el pes de calibratge. La bàscula ja està a punt per al seu ús.
NEWACALOX Milligram Scale showing a 100g calibration weight on the weighing surface, with the display showing 100.000g.

Image: Calibration with the 100g weight.

Video: This video demonstrates the calibration process and how to adjust the auto-off time for the scale.

Instruccions de funcionament

Pesatge bàsic

  1. Place the scale on a stable surface and turn it ON.
  2. Wait for the display to show "0.000g".
  3. Carefully place the item(s) to be weighed onto the center of the weighing surface.
  4. Read the stable weight displayed on the screen.
Four images showing the milligram scale weighing different items: powder, a capsule, rice, and small jewelry pieces.

Imatge: Examples of items being weighed on the scale, including powder, capsules, rice, and jewelry.

Canvi d’unitat

To change the weighing unit, press the "M" (Mode) key repeatedly to cycle through the available units: G (grams), MG (milligrams), OZ (ounces), OZT (troy ounces), DWT (pennyweights), CT (carats), GN (grains), and TL (taels).

Close-up of the scale's display and buttons, with a finger pressing the 'M' button to change units.

Image: Changing weighing units using the 'M' button.

Funció Tara

The Tare function allows you to subtract the weight of a container, so you only measure the net weight of its contents.

  1. Place an empty container (e.g., the plastic weighing pan) on the weighing surface.
  2. Press the "T" (Tare) key. The display will reset to "0.000g".
  3. Add the items you wish to weigh into the container. The display will show only the weight of the items.
  4. Nota: Some users have reported inconsistencies with the TARE button. If you experience issues, ensure the scale displays "0.000" with nothing on it before placing your container.

Counting Function (PCS)

The PCS function allows you to count multiple small items of uniform weight.

  1. Turn on the scale and wait for "0.000g".
  2. Press and hold the "P" (PCS) button until "PCS" flashes on the display.
  3. Press the "M" (Mode) button to select a sample quantity (e.g., 25, 50, 75, or 100 pieces).
  4. Place the selected sample quantity (e.g., 25 pieces) of your item onto the weighing surface.
  5. Press the "P" button once to confirm the sample. The display will show the sampla quantitat.
  6. Elimina el sample. Now, when you place any quantity of the same item on the scale, it will display the count.
  7. Atenció: For accurate counting, the items must have a consistent weight.
Image illustrating the steps to use the counting function (PCS) on the scale, showing the display changing from weight to piece count.

Image: Instructions for using the counting function.

Auto-Off Adjustment

You can adjust the automatic shut-off time to conserve battery life or keep the scale on for longer periods.

  1. With the scale OFF, press and hold the "T" (Tare) key.
  2. While holding "T", press the "On-off" key to turn the scale ON. Continue holding "T".
  3. The display will show a number (e.g., "120"), indicating the current auto-off time in seconds.
  4. Press the "M" (Mode) key to cycle through available auto-off times (e.g., 60, 120, 180 seconds, or "00" for no automatic shut-off).
  5. Once you have selected your desired auto-off time, press the "T" key briefly to confirm. The display will show "PASS" and then return to normal weighing mode.

Video: This video demonstrates how to adjust the auto-off time for the scale, including setting it to never shut off automatically.

Manteniment

  • Neteja: Netegeu la bàscula amb un suau, damp drap. No utilitzeu productes de neteja abrasius ni submergiu la bàscula en aigua.
  • Emmagatzematge: Store the scale in a cool, dry place. If not used for extended periods, remove the batteries to prevent leakage.
  • Protecció: Always use the windscreen to protect the weighing mechanism from dust and air currents.

Resolució de problemes

ProblemaCausa possibleSolució
L'escala no s'encén.Low or dead batteries; incorrect battery installation; no USB power.Replace batteries or ensure USB cable is properly connected to a working power source. Check battery polarity.
Lectures inexactes.Not calibrated; unstable surface; air currents; overloaded scale; dirty weighing surface.Perform calibration. Place on a stable, level surface. Use the windscreen. Do not exceed 100g. Clean the weighing surface.
"EEEE" or "O_LD" displayed.Error de sobrecàrrega.Remove the item immediately. Do not exceed the maximum capacity of 100g.
Tare function not working as expected.Inconsistent tare operation.Ensure the scale displays "0.000g" before placing any container. If issues persist, try recalibrating.
Counting function (PCS) is inaccurate.Items have inconsistent weight; incorrect sample quantity selected.Ensure all items for counting have a uniform weight. Double-check the sample quantity during setup.

Especificacions

CaracterísticaDetall
ModelDH100G-2
Capacitat de pes100 g
Precisió0.001 g
Weighing Amount> 0.005gr
Interval d'errorWithin ±0.005g
Tipus de visualitzacióLED amb retroiluminació
Unitats de pesatgeG, MG, OZ, OZT, DWT, CT, GN, TL
Font d'alimentació2 x AAA Batteries (included) or USB Power Supply
Característiques especialsAuto Shut Off, Calibration, Tare Function, Counting Function (PCS), Large Display, Precision Balanced, USB Power Supply, Windscreen
MaterialPlàstic
Pes de l'article0.09 quilos

Garantia i Suport

For warranty information, technical support, or any questions regarding your NEWACALOX Milligram Scale, please refer to the contact information provided with your purchase or visit the official NEWACALOX weblloc web. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.