Introducció
This manual provides essential information for the proper operation and maintenance of your U.S. Solid Digital Analytical Balance. Please read this manual thoroughly before using the scale to ensure accurate measurements and prolong the life of the instrument. This precision scale is designed for laboratory and industrial applications requiring high accuracy measurements up to 100 grams with 0.001g readability.
Informació de seguretat
- Always operate the scale on a stable, level, and vibration-free surface.
- Avoid placing the scale near strong electromagnetic fields, heat sources, or direct sunlight.
- No sobrecarregueu la bàscula més enllà de la seva capacitat màxima de 100 g.
- Keep the scale clean and free from dust, liquids, and corrosive substances.
- Handle the draft shield and weighing pan with care to prevent damage.
- Ensure the power adapter is correctly connected and use only the provided adapter.
Contingut del paquet
Verifiqueu que tots els articles siguin presents i en bon estat en desempaquetar-los.
- U.S. Solid Digital Analytical Balance
- Plat de pesatge d'acer inoxidable
- Draft Shield (Windshield)
- Adaptador d'alimentació AC/DC
- Calibration Weight (typically 100g)
- Manual d'usuari (aquest document)
Producte acabatview
Familiarize yourself with the main components and controls of the analytical balance.


Components clau:
- Plat de pesatge: Plataforma d'acer inoxidable per col·locar els elements a pesar.
- Draft Shield: Transparent enclosure to protect the weighing pan from air currents, ensuring stable and accurate readings.
- Pantalla LCD: Backlit screen showing weight readings, units, and other operational information.
- Botons de control:
- ON/OFF: Encén o apaga la bàscula.
- UNITAT: Cycles through available weighing units (g, ct, oz, lb, etc.).
- PCS (Counting Mode): Activa la funció de recompte de peces.
- CAL (Calibrate): Inicia el procés de calibratge.
- TARA/ZERO: Resets the display to zero, or tares the weight of a container.
- Bombolla d'anivellament: Indicates if the scale is perfectly level.
- Peus ajustables: Used to level the scale.
Configuració
1. Col·locació i anivellament
For optimal accuracy, place the analytical balance on a firm, stable, and level surface, free from vibrations, drafts, and direct heat.


- Place the scale on a sturdy workbench or table.
- Adjust the four adjustable feet located at the bottom of the scale until the bubble in the leveling indicator is perfectly centered. This ensures the weighing mechanism is horizontal.
2. Connexió d'alimentació
Connect the provided AC/DC power adapter to the power input port on the scale and then plug it into a suitable electrical outlet.
3. Warm-up Time
After connecting power, allow the balance to warm up for at least 30 minutes before use. This stabilizes the internal components and ensures accurate measurements. For best results, keep the scale powered on during periods of frequent use.
Instruccions de funcionament
1. Encendre/apagar
- Premeu el botó ON/OFF button to turn the scale on. The display will show a self-test sequence and then settle at 0.000g.
- Manteniu premut el botó ON/OFF botó per apagar la bàscula.
2. Calibració
Calibration is crucial for maintaining accuracy. It is recommended to calibrate the scale before first use, after moving it, or if you suspect inaccurate readings.

- Ensure the weighing pan is empty and the draft shield is closed.
- Premeu el botó CAL button. The display will show "CAL" followed by the required calibration weight (e.g., "100.000g").
- Carefully place the specified calibration weight (e.g., 100g) onto the center of the weighing pan.
- Wait for the display to stabilize and show "PASS" or return to 0.000g, indicating successful calibration.
- Traieu el pes de calibratge. La bàscula ja està a punt per al seu ús.
3. Pesatge
- Ensure the scale is powered on and displays 0.000g. If not, press TARA / ZERO.
- Carefully place the item to be weighed onto the center of the weighing pan.
- Close the draft shield to prevent air currents from affecting the reading.
- Read the stable weight displayed on the LCD.
- Remove the item from the pan.
4. Funció de tara
La funció de tara permet restar el pes d'un recipient, de manera que només es mesura el pes net del contingut.
- Place an empty container on the weighing pan. The display will show its weight.
- Premeu el botó TARA / ZERO button. The display will reset to 0.000g.
- Add the substance to be weighed into the container. The display will now show only the weight of the substance.
- To clear the tare, remove the container from the pan and press TARA / ZERO de nou.
5. Conversió d'unitats
The scale supports multiple weighing units.

- Premeu el botó UNITAT button to cycle through the available weighing units (e.g., grams (g), carats (ct), ounces (oz), pounds (lb)).
- The currently selected unit will be displayed on the LCD.
6. Piece Counting (PCS)
This function allows you to count a large number of identical items by weighing a sample.

- Place a known quantity of items (e.g., 10, 20, 50, 100 pieces) on the weighing pan.
- Premeu el botó PCS button. The display will show "PCS" and a number (e.g., "PCS 10").
- Premeu el botó UNITAT botó per seleccionar la sample size that matches the number of items you placed on the pan.
- Premeu PCS again to confirm the sample size. The display will now show the total count of items.
- You can now add more items, and the scale will display the total count.
- To exit counting mode, press the PCS botó de nou.
Manteniment
1. Neteja
- Desconnecteu sempre l'adaptador d'alimentació abans de netejar-lo.
- Netegeu l'exterior de la bàscula amb un drap suau iamp cloth. Do not use abrasive cleaners, solvents, or immerse the scale in water.
- The stainless steel weighing pan can be removed and cleaned separately with mild soap and water. Ensure it is completely dry before placing it back on the scale.
- Clean the draft shield with a soft cloth to maintain visibility.
2. Emmagatzematge
- When not in use for extended periods, store the scale in a dry, dust-free environment at room temperature.
- Keep the draft shield in place to protect the weighing mechanism.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| Display shows "Err" or unstable readings. | Overload, unstable surface, strong air currents, electromagnetic interference, or internal error. |
|
| Lectures inexactes. | Not calibrated, unstable environment, insufficient warm-up time, or dirty pan. |
|
| L'escala no s'encén. | No power, faulty adapter, or internal issue. |
|
| Tare function not working. | Funcionament incorrecte. |
|
Especificacions
| Característica | Detall |
|---|---|
| Marca | Sòlid dels EUA |
| Número de model | USS-DBS3-1 |
| Capacitat | 100 g |
| Readability / Accuracy | 0.001g / 1 mg |
| Tipus de visualització | LCD amb llum de fons |
| Unitats de pesatge | g, ct, oz, lb, N, T, GN, dr, tlT, T/A/R |
| Font d'alimentació | AC/DC Adapter (100-240V) |
| Material del plat de pesatge | Acer inoxidable |
| Dimensions del producte | 13.78 x 9.45 x 4.92 polzades |
| Pes de l'article | 4.39 lliures |
Garantia i Suport
U.S. Solid products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official U.S. Solid weblloc web o contacteu directament amb el servei d'atenció al client. Conserveu el rebut de compra per a reclamacions de garantia.
U.S. Solid Customer Service: Si us plau, visiteu www.ussolid.com per obtenir dades de contacte i recursos de suport.