1. Introducció

This user manual provides comprehensive instructions for the operation, maintenance, and troubleshooting of the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope. This advanced instrument is designed for precise signal analysis, offering high resolution and versatile measurement capabilities for various applications, including embedded systems, power electronics, and automotive electronics.

Oscil·loscopi de senyal mixt Tektronix MSO44 4-BW-200

Figura 1: Frontal view of the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope, showcasing its large touchscreen display, multiple input channels, and control knobs. The device features a blue handle for portability.

2. Configuració i configuració inicial

2.1 Desembalatge i inspecció

Carefully remove the oscilloscope from its packaging. Inspect the unit for any signs of physical damage that may have occurred during transit. Retain the original packaging for future transportation or storage.

2.2 Connexió d'alimentació

  1. Ensure the oscilloscope's power switch is in the OFF position.
  2. Connecteu el cable d'alimentació proporcionat a l'entrada de CA del panell posterior de l'oscil·loscopi.
  3. Connecteu l'altre extrem del cable d'alimentació a una presa de corrent de CA amb connexió a terra.

2.3 Encès inicial

Press the power button located on the front panel. The oscilloscope will perform a self-test and boot up. The display will show the Tektronix logo followed by the main measurement interface.

2.4 Connecting Probes and Inputs

The MSO44 features FlexChannels, which can be configured as analog or digital inputs.

  • For analog signals, connect BNC probes to the input connectors on the front panel.
  • For digital signals, use the appropriate digital probe accessories (sold separately) and connect them to the dedicated digital input ports.
  • Ensure all connections are secure to prevent signal degradation.

3. Instruccions de funcionament

3.1 S'ha acabat la interfície d'usuariview

The oscilloscope features a 13.3-inch HD capacitive touchscreen display for intuitive operation. Key controls are also available via physical knobs and buttons on the right side of the display.

3.2 Mesures bàsiques

  1. Configuració del canal: Press the channel button corresponding to the input you wish to configure. Use the touchscreen or vertical scale knob to adjust vertical sensitivity (Volts/Div).
  2. Base de temps: Use the horizontal scale knob to adjust the time base (Seconds/Div) to view el nombre de cicles desitjat.
  3. Activació: The trigger system stabilizes repetitive waveforms. Use the trigger level knob to set the trigger threshold. Select trigger type (Edge, Pulse, Runt, etc.) from the trigger menu on the screen.
  4. Mides: Access the 'Measure' menu to add automatic measurements such as frequency, peak-to-peak voltage, RMS, etc.

3.3 Funcions avançades

  • FlexChannel Technology: Each FlexChannel input can be configured as one analog channel or eight digital logic channels. This is configured through the channel setup menu.
  • High Resolution Mode: The oscilloscope offers 12-bit ADC resolution, which can be enhanced to 16 bits in High Resolution Mode for more precise measurements. Enable this mode via the display settings.
  • Durada del registre: The MSO44 features a 31.25 M record length, allowing for capture of long signal durations at high sample rates. Adjust record length settings in the acquisition menu.
  • Analysis Tools: Utilize built-in analysis tools such as FFT (Fast Fourier Transform) for frequency domain analysis, cursors for precise point measurements, and waveform math functions.

4. Manteniment

4.1 Neteja de l'instrument

To maintain the performance and appearance of your oscilloscope:

  • Exterior: Utilitzeu un suau, damp cloth with a mild detergent to clean the exterior surfaces. Avoid abrasive cleaners or solvents.
  • Visualització: Use a soft, lint-free cloth specifically designed for cleaning electronic displays. Do not spray cleaning solutions directly onto the screen.
  • Connectors: Keep input connectors clean and free of dust. Use compressed air if necessary, but avoid inserting objects into the connectors.

4.2 Calibració

The MSO44 is factory calibrated. For optimal performance, periodic calibration by a qualified service center is recommended. Refer to the Tektronix website or contact support for calibration services.

4.3 Emmagatzematge

When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the original packaging or a suitable protective case.

5. Solució De Problemes

ProblemaCausa possibleSolució
Sense pantalla després de l’encesaPower cord not connected; Power outlet issue; Internal faultCheck power cord connection; Verify power outlet functionality; Contact Tektronix support
No es mostra cap forma d'onaProbe not connected; Incorrect channel settings; Trigger not set correctly; Signal too small or largeEnsure probe is connected and functional; Check channel voltage/division settings; Adjust trigger level and type; Adjust vertical scale or input signal
Unstable waveformImproper trigger settings; Noise in signal; Grounding issueAdjust trigger source, level, and slope; Use averaging or bandwidth limit; Ensure proper grounding of the oscilloscope and circuit
La pantalla tàctil no responTemporary software glitch; Screen calibration neededRestart the oscilloscope; Refer to the full manual for touchscreen calibration procedures

6. Especificacions

The following table outlines the key technical specifications for the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope.

CaracterísticaEspecificació
Number of FlexChannels4
Bandwidth (all analog channels)200 MHz
Sample Rate (all analog/digital channels)6.25 GS/s (real-time)
Resolució vertical12 bits ADC (16 bits in High Resolution Mode)
Mostra13.3 in. color HD (1920 x 1080) capacitive touchscreen
Durada del registre31.25 M points
Dimensions del producte2.76 x 0.79 x 10.24 polzades
Pes de l'article48.75 lliures

7. Garantia i Suport

7.1 Informació de la garantia

Tektronix products are backed by a standard warranty. For detailed information regarding the warranty period and terms for your MSO44 4-BW-200 oscilloscope, please refer to the warranty card included with your product or visit the official Tektronix weblloc.

7.2 Suport tècnic

Should you encounter any issues or require technical assistance, please contact Tektronix customer support.

  • Recursos en línia: Visit the official Tektronix support website for FAQs, drivers, software updates, and additional documentation.
  • Informació de contacte: Refer to the Tektronix weblloc web per a números de contacte regionals i assistència per correu electrònic.
  • When contacting support, please have your product model number (MSO44 4-BW-200) and serial number ready.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.