1. Introducció
The AMIR Wireless Refrigerator Thermometer is designed to help you monitor temperatures in your refrigerator, freezer, or even outdoors with ease. It features two wireless sensors and a main display unit, providing real-time temperature readings and an audible alarm for temperature fluctuations, ensuring optimal food storage conditions.

Figure 1: Main display unit and two wireless remote sensors.
2. Contingut del paquet
Si us plau, comproveu el paquet per veure si hi ha els elements següents:
- 1 unitat de visualització principal
- 2 sensors remots sense fil
- 1 x Cable d'alimentació USB (per a la unitat principal)
- 1 x Manual d'usuari (aquest document)
Note: 3 x AAA batteries for the main unit and 2 x AA batteries for each remote sensor (total 4 x AA batteries) are NOT included and must be purchased separately.

Figure 2: Components of the thermometer system, highlighting battery requirements.
3. Característiques del producte
- Dual Wireless Sensors: Monitor indoor temperature and two separate outdoor/appliance temperatures simultaneously.
- Alarma sonora: Set customizable maximum and minimum temperature thresholds. The main unit will sound an alarm if temperatures exceed or fall below these set points.

Figure 3: Visual representation of the upper/lower limit alarm feature.
- Pantalla LCD fàcil de llegir: Features a large digit display for clear visibility. Records and displays Min/Max historical temperature readings, allowing you to track temperature changes.

Figura 4: Detallada view of the large LCD screen and its various indicators.
- Ampli rang de temperatures:
- Indoor: -10℃ to 60℃ (14℉ to 140℉)
- Outdoor/Sensor: -40℃ to 60℃ (-40℉ to 140℉)
- Llarg rang de transmissió: Wireless transmission range of up to 100 meters (328 feet) in open areas.
- Múltiples opcions d'instal·lació: The main display unit can be placed on a table using its built-in stand, mounted on a wall using the hang hole, or attached to a metal surface with its integrated magnet. Remote sensors can be clipped or hung.

Figure 5: Various mounting options for the main display unit.
4. Guia de configuració
4.1. Instal·lació de la bateria
- Unitat de visualització principal: Open the battery compartment on the back. Insert 3 x AAA batteries, ensuring correct polarity (+/-). Alternatively, connect the provided USB cable for continuous power.

Figure 6: Power supply options for the main unit (USB or AAA batteries).
- Sensors remots sense fil: Open the battery compartment on each sensor. Insert 2 x AA batteries into each sensor, observing correct polarity.
4.2. Emparellament de sensors
The sensors should automatically pair with the main unit once batteries are installed. If pairing does not occur, ensure both the main unit and sensors have fresh batteries and are within range. You may need to press a reset button on the sensor or main unit (refer to specific button functions in Section 5.1) to initiate pairing.
4.3. Col·locació
- Unitat de visualització principal: Place it in a convenient location where you can easily read the display. Use the fold-out stand for tabletop placement, the magnet for refrigerator doors, or the hang hole for wall mounting.
- Sensors remots sense fil: Place one sensor inside your refrigerator and the other inside your freezer. They can be clipped to a shelf or hung. For outdoor use, ensure the sensor is protected from direct weather exposure.

Figura 7: Examples of sensor and main unit placement.
5. Instruccions de funcionament
5.1. Funcions del botó
The main unit has several buttons for operation:
- ALARMA: Activates/deactivates the audible alarm.
- INDOOR/SENSOR1/SENSOR2: Cycles through alarm settings for indoor, sensor 1, and sensor 2 temperatures.
- °C/°F: Alterna entre les unitats de temperatura Celsius i Fahrenheit.
- AMUNT AVALL: Adjusts alarm temperature settings.
- ESBORAR: Clears recorded Min/Max temperatures.
5.2. Lectura de temperatures
The LCD display shows three temperature readings:
- INTERIOR: Temperature at the main display unit's location.
- SENSOR 1: Temperature from the first wireless remote sensor.
- SENSOR 2: Temperature from the second wireless remote sensor.
Each reading also shows the recorded MAX (highest) and MIN (lowest) temperatures since the last reset.
5.3. Setting Temperature Alarms
To set high and low temperature alarms for each channel:
- Premeu el botó ALARMA button to select the channel (INDOOR, SENSOR 1, or SENSOR 2) you wish to set an alarm for.
- Premeu el botó UP or ABAIX buttons to adjust the desired maximum (MAX) temperature.
- Premeu el botó ALARMA button again to move to the minimum (MIN) temperature setting for the selected channel.
- Premeu el botó UP or ABAIX buttons to adjust the desired minimum (MIN) temperature.
- Repetiu per a altres canals segons sigui necessari.
- Ensure the alarm function is activated (an alarm icon should be visible on the display for the respective channel).
6. Especificacions
| Característica | Detall |
|---|---|
| Número de model | JGUS-WA43 |
| Rang de temperatura interior | -10℃ ~ 60℃ (14℉ ~ 140℉) |
| Outdoor/Sensor Temperature Range | -40 ℃ ~ 60 ℃ (-40 ℉ ~ 140 ℉) |
| Rang de transmissió | 100M / 328ft (open area) |
| Potència de la unitat principal | 3 x AAA batteries (not included) or USB cable (included) |
| Potència del sensor | 2 x AA batteries per sensor (not included) |
| Tipus de visualització | LCD digital |
| Material exterior | Plàstic |
| Color | Negre |
| Tecnologia de connectivitat | Bluetooth |
| Dimensions del paquet | 6.22 x 3.9 x 2.72 polzades |
| Pes de l'article | 9.91 unces |

Figure 8: Product dimensions for the main unit and remote sensor.
7. Manteniment
- Neteja: Wipe the unit and sensors clean with a soft, damp tela. No submergir en aigua.
- Substitució de la bateria: Replace batteries in both the main unit and sensors when the low battery indicator appears on the display to ensure continuous and accurate readings.
- Emmagatzematge: If storing the thermometer for an extended period, remove all batteries to prevent leakage.
- Segur per al congelador: The remote sensors are designed to operate safely within freezer temperatures.
8. Solució De Problemes
- No Temperature Reading / Sensor Offline:
- Check if batteries are correctly installed and have sufficient power in both the main unit and the remote sensor. Replace if necessary.
- Ensure the remote sensor is within the 100M (328ft) transmission range of the main unit, especially in open areas. Walls and obstacles can reduce range.
- Try re-pairing the sensor by removing and reinserting its batteries, then ensuring the main unit is powered on.
- Lectures inexactes:
- Ensure sensors are not placed directly next to cooling vents or heating elements, which can cause localized temperature anomalies.
- Allow sufficient time (e.g., 30 minutes) for the sensors to stabilize after placement.
- L'alarma no sona:
- Verify that the alarm function is activated for the specific channel (check for the alarm icon on the display).
- Confirm that the set MAX/MIN alarm temperatures are appropriate for your desired range.
- Min/Max Readings Resetting Unexpectedly:
- The device may have an automatic reset interval for Min/Max readings. Consult the quick start guide or product support for specific details on this feature.
- Ensure stable power supply to the main unit. Power interruptions can sometimes reset readings.
9. Garantia i Suport
AMIR is committed to providing high-quality products and excellent customer service.
- Garantia de qualitat: This product comes with a 12-month quality guarantee from the date of purchase.
- Atenció al client: Enjoy 24/7 support and lifetime customer service. For any inquiries or assistance, please refer to the contact information provided with your product packaging or visit the official AMIR weblloc.