1. Producte acabatview
The EPEVER TRIRON 2210N is a modular-designed Maximum Power Point Tracking (MPPT) solar charge controller. It is engineered to efficiently manage power from solar panels to charge batteries, ensuring optimal energy harvesting and battery longevity. This controller features an advanced MPPT control algorithm, minimizing power loss and quickly tracking the maximum power point of the photovoltaic (PV) array under various conditions.
Les característiques clau inclouen:
- Advanced MPPT technology with an efficiency of no less than 99.5%.
- Modular design for flexible integration with different display and interface modules.
- Negative ground design, suitable for various applications such as communication base stations, household systems, street lighting, field monitoring, and RV solar systems.
- Support for 7 battery types: Sealed (AGM), Gel, Flooded, Lead-acid User, LiFePO4 Lithium, Li(NiCoMn)O2 Lithium, and Lithium User (9-34V).
- Dual 5V DC USB output interface for charging electronic devices.
- Master and slave RS485 communication modules for data reading and inverter control.
- Intuitive display with three indicators for PV, Battery, and Load status, and five buttons for parameter adjustment and browsing.

Figura 1: Frontal view of the EPEVER TRIRON 2210N MPPT Solar Charge Controller.

Figure 2: EPEVER TRIRON 2210N highlighting key specifications such as 20A current, 12/24VDC auto, Max. PV open circuit voltage, and Max. PV input power.
2. Configuració i instal·lació
Proper installation is crucial for the safe and efficient operation of your solar charge controller. Please follow these guidelines carefully.
2.1 Precaucions de seguretat
- Before wiring, ensure that the circuit breaker or fuse is open (disconnected).
- Verify that the positive ("+") and negative ("-") leads are connected correctly to prevent damage.
- Install a fuse on the battery side. The fuse current should be 1.25 to 2 times the rated current of the controller. The fuse should be located no more than 150 mm from the battery.
- If an inverter is part of the system, connect it directly to the battery, not to the load side of the controller.
2.2 Wiring Sequence
Connect the system components in the following order:
- Bateria: Connecteu la bateria al controlador.
- Càrrega: Connect the DC load to the controller.
- PV Array: Connect the solar panels (PV array) to the controller.
To disconnect the system, reverse this order: first disconnect the PV array, then the load, and finally the battery.

Figure 3: Wiring diagram illustrating the connection order for battery, load, and solar panels.

Figure 4: Product function diagram detailing connections for solar panels, battery, power inverter, and optional accessories like USB and RS485 communication modules.
2.3 Selecció del tipus de bateria
The controller supports various battery types. Ensure you select the correct battery type in the controller settings for optimal charging and discharge management. Supported types include:
- Sealed (AGM)
- Gel
- Inundat
- Lead-acid User-defined
- LiFePO4 Liti
- Li(NiCoMn)O2 Lithium
- Lithium User-defined (9-34V)
3. Funcionament
The TRIRON 2210N controller features an LCD display and buttons for monitoring and configuration.
3.1 Pantalla LCD i indicadors
The LCD provides real-time information about the system's status, including PV voltage/current, battery voltage/current/state of charge, and load status. Three color-coded indicators show the working status of the PV array, battery, and load.

Figura 5: Examples of information displayed on the LCD screen, such as voltage, current, power, and battery state of charge.
3.2 Botons
Five buttons allow users to navigate through menus, adjust parameters, and view system data. Refer to the on-screen prompts for specific button functions during operation.
3.3 Sortida USB
The dual 5V DC USB output interfaces can be used to charge compatible electronic devices directly from the controller.
3.4 Mòduls de comunicació
The controller supports master and slave RS485 communication modules. These modules enable reading of load or inverter operating data and can control inverter switches via a relay interface. This functionality allows for remote monitoring and control, often through a mobile application or PC software.

Figure 6: Optional replaceable accessories, such as display modules (DB1, DS1), relay modules (RCM, RCS), and USB communication modules (USB1).

Figure 7: Illustration of the modular design, allowing for easy replacement or addition of components like the display and communication interfaces.
4. Manteniment
To ensure the longevity and optimal performance of your EPEVER TRIRON 2210N solar charge controller, regular maintenance is recommended.
- Inspecció visual: Periodically check for any loose connections, damaged wiring, or signs of corrosion.
- Neteja: Keep the controller free from dust and debris to ensure proper heat dissipation.
- Actualitzacions de firmware: Comproveu el del fabricant weblloc web per a qualsevol actualització de firmware disponible que pugui millorar el rendiment o afegir funcions.
- Verificació de paràmetres: Occasionally verify that the battery type and other configured parameters match your system requirements.
Always disconnect power from the solar panels and battery before performing any maintenance or cleaning.
5. Solució De Problemes
Aquesta secció proporciona orientació general per a problemes comuns. Per a problemes complexos, contacteu amb l'assistència tècnica.
- Sense pantalla/alimentació:
- Comproveu les connexions de la bateria i assegureu-vos que estiguin ben fixades i polaritzades.
- Verify that the battery fuse is intact and properly rated.
- Assegureu-vos que la bateria voltage està dins del rang de funcionament del controlador.
- No Charging from PV:
- Check PV array connections for proper polarity and secure contact.
- Ensure solar panels are receiving adequate sunlight and are not shaded.
- Verify that the PV open circuit voltage is within the controller's specifications.
- Incorrect Battery Charging:
- Confirm that the correct battery type is selected in the controller settings.
- Check battery health and capacity.
- Problemes de comunicació:
- Ensure RS485 cables are correctly connected and not damaged.
- Verify that any connected communication modules (e.g., Bluetooth, WiFi) are properly installed and configured.
The controller is designed with comprehensive electronic protection functions to minimize damage from incorrect installation or system failure. If issues persist, consult the detailed troubleshooting guide in the full product manual or contact EPEVER support.
6. Especificacions
The following table outlines the key electrical and physical specifications for the EPEVER TRIRON 2210N MPPT Solar Charge Controller.

Figure 8: Detailed electrical parameters for various TRIRON N series models, including the TRIRON 2210N.
| Paràmetre | Valor |
|---|---|
| Sistema nominal Voltage | 12V/24VDC Auto Work |
| Corrent de càrrega nominal | 20A |
| Corrent nominal de descàrrega | 20A |
| Volum d'entrada de bateriatage Rang | 8~32V |
| Màx. Circuit obert PV Voltage | 100V (Min. operating environment temp), 92V (25°C environment temp) |
| MPP Voltage Rang | (Vbat+2V)~72V |
| Màx. Potència d'entrada fotovoltaica | 260W/12V, 520W/24V |
| Tipus de bateria compatibles | Sealed, Gel, Flooded, Lead-acid User, LiFePO4, Li(NiCoMn)O2, Lithium User |
| Equalize Charge Voltage (Lead-acid) | Sealed: 14.6V, Flooded: 14.8V, User-defined: 9~17V |
| Volum de càrrega d’augmenttage (Lead-acid) | Gel: 14.2V, Sealed: 14.4V, Flooded: 14.6V, User-defined: 9~17V |
| Vol. De càrrega flotanttage (Lead-acid) | Gel/Sealed/Flooded: 13.8V, User-defined: 9~17V |
| Volum baixtage Reconnect Voltage (Lead-acid) | Gel/Sealed/Flooded: 12.6V, User-defined: 9~17V |
| Volum baixtage Desconnectar Voltage (Lead-acid) | Gel/Sealed/Flooded: 11.1V, User-defined: 9~17V |
| Temperatura de funcionament | -20 °C a +50 °C |
| Dimensions (L x A x A) | 216 mm x 150 mm x 57 mm |
| Pes de l'article | 1.21 kg (2.66 lliures) |
| Tipus de visualització | LCD |
| UPC | 732376583305 |

Figure 9: Physical dimensions of the TRIRON 2210N controller.
7. Garantia i Suport
For warranty information, please refer to the documentation included with your product or contact EPEVER directly. For technical support, troubleshooting assistance, or inquiries regarding product selection and compatibility, you may contact the manufacturer or authorized distributors.
Fabricant: EPEVER