Elitech Tlog B100EH

Elitech Tlog B100EH Temperature and Humidity Data Logger User Manual

Model: Tlog B100EH

1. Introducció

The Elitech Tlog B100EH is a wireless temperature and humidity data logger designed for precise environmental monitoring. It features an external sensor, a large recording capacity of 32,000 points, and the ability to generate PDF reports. This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your device.

Elitech Tlog B100EH Data Logger with External Sensor

Image 1.1: Elitech Tlog B100EH Data Logger with external temperature and humidity sensor.

2. Producte acabatview

Familiarize yourself with the components of your Tlog B100EH data logger.

Labeled diagram of Elitech Tlog B100EH components

Image 2.1: Key components of the Elitech Tlog B100EH, including the external sensor, LED indicators, LCD screen, control buttons, and USB cover.

  • Sensor extern: Mesura la temperatura i la humitat.
  • LED Indicator (Mode): Indicates device status (e.g., logging, stopped).
  • LED Indicator (Alarm): Indicates if recorded data exceeds set alarm thresholds.
  • Pantalla LCD: Displays current readings, battery status, and logging status.
  • Botó INICI: Initiates data logging.
  • Botó STOP: Halts data logging.
  • Coberta USB: Protects the integrated USB connector for PC connection.

3. Configuració

3.1 Instal·lació de la bateria

The Tlog B100EH uses a replaceable lithium battery (included). Ensure the battery is correctly installed before first use.

Battery compartment of Elitech Tlog B100EH

Imatge 3.1: posterior view of the data logger showing the battery compartment. Ensure proper battery orientation.

3.2 Instal·lació de programari i aplicacions

To configure the data logger and view detailed reports, install the Elitech software on your computer or the Elitech App on your iOS/Android device.

  1. Programari de PC: Download the Elitech data management software from the official Elitech weblloc. Seguiu les instruccions que apareixen a la pantalla per a la instal·lació.
  2. Aplicació mòbil: Cerca 'Elitech' in the Apple App Store or Google Play Store and install the application.

3.3 Configuració inicial

Before starting a new logging session, connect the device to your computer via USB or pair it with the Elitech App via Bluetooth to set parameters.

Elitech Tlog B100EH connected to PC and mobile app

Image 3.2: The data logger connected to a computer via USB and displaying data on a mobile application.

Using the software/app, you can configure:

  • Interval de registre
  • Start/Stop mode
  • Alarm thresholds for temperature and humidity
  • Hora d'inici retardat
  • Unit of measurement (°C/°F)

4. Instruccions de funcionament

4.1 Starting and Stopping Logging

The Tlog B100EH features a button recess design to prevent accidental activation or deactivation during transport.

Close-up of Elitech Tlog B100EH buttons

Imatge 4.1: Primer pla view of the recessed START and STOP buttons on the data logger.

  • To Start Logging: Manteniu premut el botó COMENÇA button until the 'Mode' LED flashes green, indicating logging has begun.
  • To Stop Logging: Manteniu premut el botó STOP button until the 'Mode' LED stops flashing, indicating logging has ceased.

4.2 Monitoring Data

The LCD screen displays real-time temperature and humidity readings, battery level, and logging status. The 'Alarm' LED will illuminate if readings exceed configured thresholds.

4.3 Exportació de dades i generació d'informes

After logging is complete, connect the data logger to a computer via USB or use the Elitech App to download the recorded data.

Elitech Tlog B100EH data export via software

Image 4.2: Data export interface showing the data logger connected to a computer and a mobile device, illustrating multi-format data export options.

PDF, Excel, and TXT report icons

Image 4.3: Icons representing the available data report formats: PDF, Excel, and TXT.

The software/app allows you to generate reports in various formats, including PDF, Excel, and TXT, for analysis and record-keeping.

5. Manteniment

5.1 Substitució de la bateria

When the battery indicator on the LCD shows low power, replace the lithium battery to ensure continuous operation. Refer to Section 3.1 for battery access.

5.2 Neteja

Netegeu el dispositiu amb un drap suau i sec. No utilitzeu productes de neteja abrasius ni submergiu el dispositiu en aigua.

5.3 Emmagatzematge

Store the data logger in a cool, dry place away from direct sunlight and extreme temperatures when not in use.

6. Solució De Problemes

  • El dispositiu no s'encén: Check battery installation and charge level. Replace battery if necessary.
  • No es pot connectar mitjançant Bluetooth: Ensure Bluetooth is enabled on your mobile device and the data logger is within range. Restart both devices and try pairing again.
  • Data not logging: Verify that logging was initiated correctly by checking the 'Mode' LED. Ensure sufficient memory is available.
  • Lectures inexactes: Ensure the external sensor is clean and unobstructed. Avoid placing the sensor in direct sunlight or near heat sources.
  • Software/App issues: Ensure you have the latest version of the software/app. Refer to the Elitech support website for common software issues.

For further assistance, contact Elitech customer support.

7. Especificacions

Elitech Tlog B100EH dimensions and measurement range

Image 7.1: Physical dimensions and operational temperature/humidity ranges of the data logger.

Elitech Tlog B100EH sensor accuracy and data points

Image 7.2: Details on sensor accuracy, resolution, and total data logging capacity.

Temperature and humidity sensor accuracy

Image 7.3: Visual representation of the temperature and humidity sensor accuracy.

CaracterísticaDetall
Número de modelTlog B100EH
Interval de temperatura-40 °F a 185 °F (-40 °C a 85 °C)
Gamma d’humitat10% a 90% HR
Precisió de la temperatura±0.6℉ (±0.3°C)
Precisió de la humitat±3% HR
Capacitat d’enregistrament32,000 punts
Tipus de bateria1 bateria de metall de liti (inclosa)
Dimensions del producte6.12 x 1.85 x 0.64 polzades
Pes de l'article4.97 unces (0.14 quilograms)
Tipus de muntatgeTaula

7.1 Quality Certifications

Elitech Quality Certifications

Imatge 7.4: acabatview of Elitech's quality certifications, including WHO PQS, FDA, and NIST compliance.

The Elitech Tlog B100EH complies with various quality standards, including:

  • World Health Organization PQS Approved
  • FDA21 CFR Part 11 Compliance
  • ISO 9001:2015
Exampd'un certificat de calibratge

Imatge 7.5: Ex.ample of a calibration certificate, showing calibration and expiration dates.

Calibration certificates are available upon request. Please contact Elitech customer support for details.

8. Garantia

Elitech provides a standard manufacturer's warranty for this product. Please refer to the warranty card included with your purchase or visit the official Elitech weblloc web per obtenir informació detallada sobre els termes i condicions de la garantia.

9. Suport

For technical assistance, troubleshooting, or any inquiries regarding your Elitech Tlog B100EH data logger, please contact Elitech customer support. 24/7 US Technician Support is available via email and phone.

  • Correu electrònic: Refer to your product packaging or the Elitech weblloc per obtenir informació de contacte.
  • Telèfon: Refer to your product packaging or the Elitech weblloc per obtenir informació de contacte.
  • Recursos en línia: Visit the official Elitech weblloc web per a preguntes freqüents, descàrregues de programari i materials de suport addicionals.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.