Tektronix TBS2074B

Manual d'usuari de l'oscil·loscopi digital Tektronix TBS2074B

Model: TBS2074B | Brand: Tektronix

1. Introducció

The Tektronix TBS2000B series digital oscilloscopes are designed to provide high-level signal display and measurement, which are critical functions for any oscilloscope. The TBS2074B model, with its 70MHz bandwidth and 4 channels, offers an intuitive user experience and powerful analysis capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your TBS2074B oscilloscope.

Tektronix TBS2074B Digital Oscilloscope front view

Figura 1.1: Frontal view of the Tektronix TBS2074B Digital Oscilloscope.

2. Característiques clau

The TBS2074B oscilloscope is equipped with features designed to enhance usability and measurement accuracy:

  • Bandwidth and Sampli Rate: 70MHz bandwidth with a maximum sample rate of 2GS/s (half channel) or 1GS/s (all channels).
  • Pantalla gran: Features a 9-inch WVGA color display with 15 horizontal divisions, allowing for 50% more signal visibility on a single screen.
  • Durada del registre: A 5M-point record length enables the capture of long-duration data.
  • TekVPI Probe Interface: Supports active, differential, and current probes with automatic scaling and unit settings.
  • Mesures automàtiques: Includes 32 powerful automatic measurement functions for comprehensive waveform analysis.
  • Funció FFT: Provides fast waveform analysis capabilities.
  • Search/Mark Function: Easily identify events within captured waveforms.
  • HelpEverywhere: Context-sensitive help is available directly on the device.
  • Built-in Handbook: An online handbook explains oscilloscope basics and operation procedures.
  • Suport multi-idioma: User interface and front panel overlays support 10 languages.
  • Connectivitat: Supports Wi-Fi and 10/100BASE-T Ethernet for easy data sharing and remote control.

3. Configuració

3.1 Desembalatge

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Retain the original packaging for future transport or storage.

3.2 Connexió de potència

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the power source meets the voltage and frequency requirements specified on the device label.

posterior view of Tektronix TBS2074B showing power input and connectivity ports

Figure 3.1: Rear panel of the oscilloscope with power input and connectivity ports.

3.3 Encès inicial

Press the power button located on the front panel. The oscilloscope will perform a self-test and then display the main waveform screen. Allow a few moments for the system to fully initialize.

4. Funcionament

4.1 S'ha acabat la interfície d'usuariview

The TBS2074B features a large 9-inch display and an intuitive front panel with dedicated controls for vertical, horizontal, and trigger settings. Navigation buttons and a rotary knob allow for easy menu access and parameter adjustment.

Tektronix TBS2074B display showing 15 horizontal divisions

Figure 4.1: The oscilloscope display highlighting the 15 horizontal divisions for extended signal view.

4.2 Mesures bàsiques

To perform a basic measurement:

  1. Connect the appropriate probe to one of the input channels (CH1-CH4) on the front panel.
  2. Connect the probe tip to the circuit point you wish to measure.
  3. Adjust the vertical scale (Volts/Div) and horizontal scale (Sec/Div) knobs to display the waveform clearly.
  4. Use the Trigger controls to stabilize the waveform on the screen.
  5. Press the 'Measure' button to access automatic measurement options.
Tektronix TBS2074B with probes connected to input channels

Figure 4.2: Connecting probes to the oscilloscope input channels.

4.3 Funcions avançades

The TBS2074B offers advanced analysis tools:

  • Mesures automàtiques: Select from 32 different automatic measurements (e.g., Peak-to-Peak, Frequency, Rise Time) to quickly quantify waveform characteristics.
  • FFT Analysis: Use the Fast Fourier Transform (FFT) function to analyze the frequency components of your signal.
  • Search/Mark: Utilize the search and mark feature to automatically identify and navigate to specific events or anomalies within a long waveform record.
Tektronix TBS2074B display showing automatic measurement menu

Figure 4.3: The automatic measurement selection menu on the oscilloscope display.

Tektronix TBS2074B display showing waveform with search and mark function in use

Figure 4.4: Waveform display demonstrating the search and mark function.

5. Connectivitat

The TBS2074B offers various connectivity options for data transfer and remote control:

  • Front Panel USB 2.0 Host Port: Easily save waveform data, screenshots, or instrument settings to a USB flash drive.
  • Rear Panel USB 2.0 Device Port: Connect the oscilloscope to a PC for remote control and data transfer using compatible software.
  • 10/100BASE-T Ethernet Port: Enables remote control and data sharing over a local area network (LAN).
  • Interfície Wi-Fi: Supports wireless communication for convenient data access and sharing.
Close-up of the rear panel of Tektronix TBS2074B showing USB and Ethernet ports

Figura 5.1: Primer pla view of the rear panel connectivity ports.

Tektronix TBS2074B connected to a laptop via USB cable

Figure 5.2: The oscilloscope connected to a laptop for data transfer or remote control.

6. Manteniment

6.1 Neteja

To maintain the performance and appearance of your oscilloscope, regularly clean the exterior surfaces. Use a soft, damp cloth with a mild detergent. Avoid abrasive cleaners or solvents that could damage the plastic components or display.

6.2 Emmagatzematge

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to use the original packaging or a protective case.

7. Solució De Problemes

This section provides solutions to common issues you might encounter with your TBS2074B oscilloscope.

ProblemaCausa possibleSolució
Sense poderCable d'alimentació no connectat; Avaria de la presa de corrent; Fusible intern funditComproveu la connexió del cable d'alimentació; proveu la presa de corrent; contacteu amb el servei tècnic per substituir el fusible
No es mostra cap forma d'onaProbe not connected; Incorrect vertical/horizontal settings; Trigger not set correctlyEnsure probe is connected; Adjust Volts/Div and Sec/Div; Adjust trigger level or mode
Unstable waveformIncorrect trigger source or level; Signal noiseVerify trigger source and adjust trigger level; Use averaging or bandwidth limit to reduce noise

If you encounter issues not covered here, or if the suggested solutions do not resolve the problem, please contact Tektronix customer support.

8. Especificacions

Detailed technical specifications for the Tektronix TBS2074B Digital Oscilloscope:

EspecificacióValor
FabricantTektronix
Número de modelTBS2074B
Ample de banda70 MHz (Upgradeable to 200 MHz with option)
Canals analògics4
Max Sampli Rate2 GS/s (half channel), 1 GS/s (all channels)
Durada del registre5 M points
Mostra9-inch WVGA Color Display
Mesures automàtiques32 tipus
Interfície de sondaTekVPI
ConnectivitatUSB 2.0 Host (front), USB 2.0 Device (rear), 10/100BASE-T Ethernet, Wi-Fi
Pes de l'article3 quilos
Dimensions del paquet50 x 40 x 26 cm
Components inclososStandard Accessory KIT
Batteries UsedNo
Primera data disponible (Amazon.co.jp)2020/5/11

9. Garantia i Suport

Tektronix products are designed for reliability and performance. For information regarding warranty coverage, technical support, and service, please refer to the official Tektronix website or contact your local Tektronix representative. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, visit the official Tektronix support page: www.tek.com/support

© 2024 Tektronix. All rights reserved. Information in this document is subject to change without notice.

Documents relacionats - TBS2074B

Preview Tektronix 2246 Portable Oscilloscope Operators Manual
Comprehensive operators manual for the Tektronix 2246 portable oscilloscope. Includes safety summaries, technical specifications, performance conditions, and operating instructions for this 100 MHz four-channel instrument.
Preview Especificacions i verificació del rendiment de l'oscil·loscopi MSO Tektronix sèrie 4
Especificacions tècniques completes i procediments de verificació del rendiment per als oscil·loscopis de senyal mixt (MSO) de la sèrie 4 de Tektronix, inclosos els models MSO44, MSO46, MSO44B i MSO46B. Aquest document detalla les capacitats de l'instrument i els mètodes de prova.
Preview Ajuda per a l'oscil·loscopi de domini mixt Tektronix sèrie 3 (MD032, MD034)
Guia d'usuari per a l'oscil·loscopi de domini mixt Tektronix sèrie 3 (MD032, MD034), que detalla les característiques, el funcionament, la configuració i la resolució de problemes d'aquest instrument avançat de prova i mesura.
Preview Tektronix 5/6 Series MSO: Printable Help Guide
Comprehensive printable help guide for Tektronix 5/6 Series Mixed Signal Oscilloscopes (MSO54, MSO56, MSO58, MSO58LP, MSO64), covering features, installation, operation, and configuration.
Preview Guia d'ajuda de l'oscil·loscopi de rendiment DPO Tektronix sèrie 7 DPO714AX
Guia d'ajuda completa per a l'oscil·loscopi de rendiment DPO Tektronix sèrie 7, model DPO714AX. Apreneu sobre les característiques, el funcionament, la configuració i la resolució de problemes d'aquest instrument de prova i mesura avançat.
Preview Manual de servei de l'oscil·loscopi Tektronix 335
Service and maintenance manual for the Tektronix 335 portable oscilloscope, including specifications, circuit descriptions, troubleshooting, and adjustment procedures.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.