The Pedrollo 2CPm2516C water pump is a horizontal centrifugal pump with two impellers, specifically designed for industrial water distribution and various agricultural applications. This pump is suitable for handling clean liquids without abrasive particles and non-aggressive to the pump components.

It is engineered for reliable performance within a liquid temperature range of -10 °C to +90 °C. The ambient temperature for the pump's storage and operation should not exceed 40 °C.

The pump body is constructed from robust cast iron with threaded ports, designed to withstand a maximum working pressure of 10 bar. It features durable brass impellers and a cast iron motor lantern. The electric motor operates at 2900 rpm, offering IPX4 protection, Class F insulation, and S1 continuous service. The IE3 class electric motor ensures high efficiency and low power consumption. For the single-phase 220V model, thermal protection is integrated to prevent overheating.

The coupling shaft between the impeller and electric motor is made of stainless steel EN 10088-3 - 1.4104, ensuring corrosion resistance and longevity. The standard mechanical seal, composed of carbon, ceramic, and nitrile, provides effective sealing between the pump body and electric motor. This seal set is replaceable, contributing to the extended lifespan of the water pump.

2. Informació de seguretat

  • Always disconnect the pump from the power supply before any installation, maintenance, or repair work.
  • Ensure the electrical installation complies with local regulations and standards.
  • The pump must be properly grounded to prevent electrical shock.
  • Do not operate the pump dry; ensure it is always primed with liquid before starting.
  • Protect the pump from frost and extreme weather conditions.
  • Mantingueu els nens i el personal no autoritzat allunyats de la bomba durant el funcionament.
  • Utilitzeu l'equip de protecció individual (EPI) adequat quan manipuleu la bomba.

3. Configuració i instal·lació

3.1 Desembalatge i inspecció

Carefully remove the pump from its packaging. Inspect for any signs of damage during transit. Report any damage to the supplier immediately.

3.2 Col·locació

  • Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and frost.
  • Ensure the ambient temperature does not exceed 40 °C.
  • Munteu la bomba sobre una superfície estable i plana per minimitzar les vibracions.
  • Allow sufficient space around the pump for ventilation and maintenance access.

3.3 Piping Connections

  • Use pipes of adequate diameter to minimize pressure loss.
  • Install a foot valve with a strainer at the end of the suction pipe to prevent debris from entering the pump and to maintain prime.
  • Ensure all connections are airtight to prevent air leaks, which can affect pump performance.
  • Support the piping independently to avoid placing stress on the pump's connections.
  • Install a gate valve on both the suction and discharge sides for isolation during maintenance.

3.4 Connexió elèctrica

  • Connect the pump to a 220V single-phase power supply.
  • Ensure the power supply matches the pump's specifications.
  • The pump must be connected to a circuit protected by a residual current device (RCD) and an appropriately rated circuit breaker.
  • Tot el treball elèctric ha de ser realitzat per un electricista qualificat.

4. Instruccions de funcionament

4.1 Cebament de la bomba

Before the first start-up, or if the pump has run dry, it must be primed:

  1. Ensure the discharge valve is closed.
  2. Open the priming plug (if available) or the highest point of the pump casing.
  3. Ompliu la bomba casing and the suction line completely with clean water until no more air bubbles emerge.
  4. Close the priming plug securely.

4.2 Engegada de la bomba

  1. Ensure the pump is properly primed.
  2. Open the discharge valve slowly.
  3. Connecteu l'alimentació a la bomba.
  4. Monitor the pump for unusual noises or vibrations. If any occur, switch off immediately and investigate.

4.3 Parada de la bomba

  1. Close the discharge valve slowly.
  2. Switch off the power supply to the pump.

5. Manteniment

5.1 Comprovacions periòdiques

  • Periodically check for leaks around seals and connections.
  • Inspect the power cable for damage.
  • Listen for unusual noises or vibrations during operation.
  • Ensure the motor's ventilation openings are clear of obstructions.

5.2 Neteja

Clean the exterior of the pump regularly to prevent dust and dirt buildup, which can affect cooling.

5.3 Winterization (for non-permanent installations)

If the pump is not used during freezing temperatures:

  1. Desconnecteu la font d'alimentació.
  2. Drain all water from the pump and piping to prevent frost damage.
  3. Guardeu la bomba en un lloc sec i sense gelades.

6. Solució De Problemes

ProblemaCausa possibleSolució
La bomba no arrencaSense font d'alimentació
S'ha disparat la sobrecàrrega tèrmica
Falla del motor
Comproveu la connexió d'alimentació i l'interruptor automàtic
Allow motor to cool, check for cause of overload
Contacta amb un tècnic qualificat
Pump runs but no water flowBomba no imprimada
Fuga d'aire a la línia d'aspiració
Vàlvula de peu obstruïda
Impulsor bloquejat
Torneu a cebar la bomba
Check all suction connections for leaks
Clean foot valve and strainer
Inspect and clear impeller (disconnect power first)
Flux o pressió reduïtsBloqueig parcial
Aire al sistema
Worn impeller/seals
Check for blockages in pipes or strainer
Check for air leaks, re-prime
Contact qualified technician for inspection
Excés de soroll o vibracióCavitation (air in pump)
Muntatge solt
Bearing wear
Foreign object in pump
Check priming, suction conditions
Premeu els cargols de muntatge
Contacta amb un tècnic qualificat
Inspect and remove object (disconnect power first)

7. Especificacions

CaracterísticaEspecificació
MarcaPedrollo
Model2CPm2516C
Poder1.10 kW (1.5 CV)
Voltage220 V, Single-phase
Freqüència50 Hz
Caudal màxim7.2 m³/h
Max Head (HMT)47 metres
Rang de temperatura del líquid-10 °C a +90 °C
Interval de temperatura ambientMàxim 40 °C
Material del cos de la bombaFerro colat
Material del rodetLlautó
Protecció del motorIPX4
Classe d'aïllamentF
Velocitat del motor2900 rpm
Material de l'eixStainless Steel EN 10088-3 - 1.4104
Segell mecànicCarbon-Ceramic-Nitrile
Pressió màxima de treball10 bar
Ús específicIndustrial water distribution and agricultural applications
País d'origenItàlia

8. Corbes de rendiment

Performance curve for Pedrollo 2CP series pumps, showing flow rate (Q) versus total head (HMT) at 50 Hz and 2900 rpm.
Performance curve for Pedrollo 2CP series pumps, showing flow rate (Q) versus total head (HMT) at 50 Hz and 2900 rpm. This graph helps determine the pump's capabilities under various operating conditions.

9. Explotat View Diagrama

Diagram illustrating the internal components of the Pedrollo 2CPm2516C water pump, including impellers, motor, and seals.
Diagram illustrating the internal components of the Pedrollo 2CPm2516C water pump. Key components are numbered for reference: 1. Suction port, 2. Discharge port, 3. Impellers, 4. Mechanical seal, 5. Shaft, 6. Bearings, 7. Motor windings, 8. Rotor.

10. Garantia i Suport

For warranty information, technical support, or spare parts, please contact your authorized Pedrollo dealer or the manufacturer directly. Keep your purchase receipt and product model number (2CPm2516C) handy for any inquiries.

© 2023 Pedrollo. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.