RENOGY RNG-DCC1212-60-JP

Renogy DC-DC 12V 60A Battery Charger Instruction Manual

Model: RNG-DCC1212-60-JP

1. Informació de seguretat

Please read all instructions and warnings in this manual carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.

  • Always wear appropriate personal protective equipment, including eye protection, when working with batteries and electrical systems.
  • Ensure all connections are tight and secure to prevent loose connections that can cause excessive heat and damage.
  • Do not operate the charger in wet or damp condicions.
  • Assegureu-vos que hi hagi una ventilació adequada al voltant del carregador per evitar el sobreescalfament.
  • Disconnect all power sources before performing any maintenance or troubleshooting.
  • Do not attempt to disassemble or repair the charger yourself. Contact qualified service personnel.

2. Producte acabatview

2.1 Característiques clau

  • Compatibilitat versàtil de bateries: The Renogy DC-DC charger is compatible with multiple alternator types and sub-battery types, including AGM, flooded, gel, and lithium-ion batteries.
  • Smart 3-Stage Càrrega: This battery charger charges the sub-battery from the starter battery using a 3-stage charging process (bulk, boost, float), ensuring optimal and automatic 100% charge.
  • Main Battery Over-Discharge Protection: The DC-DC battery charger identifies whether the generator is running, preventing over-discharge of the starter battery and protecting the main battery.
  • Seguretat millorada: Provides over-voltage protection, over-temperature protection, and reverse polarity protection, ensuring safe operation. It also isolates input and output to prevent voltage transmission errors and protect the house battery from overcharging.
  • Disseny durador: Features a compact and robust construction for reliable performance.

2.2 Dimensions del producte

Renogy DC-DC Charger with dimensions: 31.1 cm length, 17.5 cm width, 6.8 cm height

The image above shows the Renogy DC-DC Charger with its dimensions: 31.1 cm length, 17.5 cm width, and 6.8 cm height.

2.3 Descripció de les peces

Diagram of Renogy DC-DC Charger ports and indicators

This diagram illustrates the various ports and indicators on the Renogy DC-DC Charger.

#MarcDescripció
1Entrada (+)Main Battery Positive
2Entrada (-)Main Battery Negative
3Indicador d'alimentacióLED indicador d'alimentació
4Indicador d'errorError Indicator LED
5S1 S2 S3 S4 S5Battery Type Setting Switch (DIP Switches)
6RJ11Temperature Sensor Connection Port
7D+Signal Line Connection Port
8LCCurrent Limit Port
9Sortida (+)Sub-battery Positive
10Sortida (-)Sub-battery Negative

3. Configuració i instal·lació

3.1 Diagrama de connexió

Wiring diagram for Renogy DC-DC Charger connecting to main and sub-batteries in an RV

This diagram illustrates the wiring connections for the DC-DC Charger in a typical RV setup, connecting to both the main (starter) battery and the sub-battery (house battery).

  • DC-DC Charger ↔ Main Battery Wiring
  • DC-DC Charger ↔ Sub-battery Wiring
  • DC-DC Charger D+ Port ↔ Alternator D+ Terminal Wiring

Nota: All wiring requires separate purchase. Cables are not included with this product; please prepare them separately if needed.

3.2 Configuració del commutador DIP

DIP switch settings for Renogy DC-DC Charger to adjust battery type and charging voltage

The image shows the DIP switches used to configure the charger. By operating the 5 switches (S1-S5), you can adjust the battery type and charging voltage.

  • S1 and S2: Set Absorption Voltage
  • S3 and S4: Estableix el volum de càrrega flotanttage
  • S5: Set Charging Mode

3.3 Selecció de la mida del cable

Table showing recommended cable sizes and fuse ratings for different DC-DC charger models

Refer to this table for recommended cable sizes and fuse ratings based on your specific DC-DC charger model and cable length.

ModelCableMida mínima del cableFusible
DCC-1212-20Bateria principal0.61m 5.5sq2.44m 5.5sq4.88m 8.0sq9.75m 22sq30A
Subbateria0.61m 3.5sq2.44m 3.5sq4.88m 5.5sq9.75m 14sq25A
DCC-1212-40Bateria principal0.61m 14sq2.44m 14sq4.88m 22sq9.75m 38sq60A
Subbateria0.61m 8.0sq2.44m 8.0sq4.88m 14sq9.75m 22sq50A
DCC-1212-60Bateria principal0.61m 22sq2.44m 22sq90A
Subbateria0.61m 14sq2.44m 14sq4.8m 22sq75A
D+/LC0.75~1.2SQ

3.4 D+ and LC Ports

Close-up of D+ and LC ports on Renogy DC-DC Charger

The image highlights the D+ and LC ports on the charger.

  • D+ Port: Connects to the alternator's D+ terminal for smart alternator detection.
  • LC Port: By connecting to the LC port, the charging current can be limited by half. (Recommended cable size: 0.75~1.2SQ)

4. Funcionament

4.1 3-Stage Procés de càrrega

Gràfic que il·lustra les 3-stage charging process: Bulk, Absorption, and Float

The graph above illustrates the 3-stage charging process (Bulk, Absorption, Float) that fully charges the battery.

  • A granel: Charges the battery at the maximum current until it reaches a set voltage.
  • Absorció: Charges at a constant voltage, reducing current as the battery approaches full charge.
  • Flotador: Maintains the battery at a constant, lower voltage to prevent self-discharge.

4.2 Indicadors LED

The charger features LED indicators to communicate the charging status and battery type. Refer to the tables below for detailed explanations.

Indicador de tipus de bateria
ColorEstatDescripció
VerdONSLA (per defecte)
grocONGEL
VermellONFLD (Flooded)
BlauONLI (Lithium)
BlancONUser (Requires BT-2 Module and Renogy DC Home App)
Indicador de bateria de servei
ColorEstatDescripció
VerdONBateria plena
grocONBateria voltagi normal
VermellONBateria subvoltage
VermellParpelleig lentBateria excessivament descarregada
VermellIntermitent ràpidBateria sobre voltage/sobretemperatura

Nota: L'indicador de càrrega pot canviar en les condicions següents:

  1. De vermell a groc: quan el voltage arriba a 12.2V sota voltage recuperació.
  2. De groc a vermell: quan el voltagcau a 12.0V sota voltage advertència.
  3. De groc a verd: A. Quan arriba al vol constanttagEn estat de càrrega, el corrent de càrrega és inferior a 3A i dura 30 segons; B. Quan el corrent de càrrega és superior a 3A, es continua carregant fins que arriba al vol constanttagL'estat i el corrent cauen per sota de 3A, dura 30 segons.
Alternador / Indicador de càrrega
ColorEstatDescripció
VerdONL'alternador està carregant la bateria de servei
VermellParpelleig lentPV està carregant la bateria d'arrencada
OFFNo carregant

4.3 Alternator Type and Starting Battery Voltage

Tipus d'alternadorStarting Battery Voltage
TallatTall
Alternador tradicional>13.2V, for 15 seconds<12.7V
Alternador intel·ligent>12.0V, for 15 seconds<11.5V

4.4 Charging Current Distribution (Solar + Alternator)

ModelRBC30DISRBC50DIS
Només solar30A50A
Only Alt30A50A
Solar + ALT15A + 15A25A + 25A

When using both solar and alternator inputs, the current is split. For example, the RBC30DIS model will provide 15A from solar and 15A from the alternator, totaling 30A.

5. Manteniment

Regular maintenance ensures optimal performance and longevity of your Renogy DC-DC Charger.

  • Periodically check all wiring connections for tightness and corrosion. Clean any corroded terminals.
  • Inspect the charger for any physical damage or signs of overheating.
  • Ensure the area around the charger is free from dust and debris to maintain proper ventilation.
  • Verify that the battery type settings are correct for your installed batteries.

6. Solució De Problemes

If you encounter issues with your DC-DC Charger, refer to the following basic troubleshooting steps:

  • Sense alimentació/LED apagats: Check all battery connections and fuses. Ensure the starter battery voltage is above the cut-in threshold.
  • Error Indicator On: Refer to the LED Indicators section (4.2) for the specific error type (over-voltage, over-temperature, reverse polarity, etc.) and take corrective action.
  • La bateria no es carrega: Verify that the correct battery type is selected using the DIP switches. Check solar panel connections and output, and ensure the alternator is functioning correctly.
  • Reduced Charging Current: Ensure the LC port is not connected if full current is desired. Check cable sizes against recommendations in section 3.3.

For persistent issues, please contact Renogy customer support.

7. Especificacions

EspecificacióValor
MarcaRENOGIA
ColorNegre
Dimensions del producte (P x A x A)17.5 x 31.1 x 6.8 cm
Vol. De sortidatage12 Volts
Normes de complimentCE, RoHS
Corrent nominal60 Amps
Número de model del fabricantRNG-DCC1212-60-JP
GTIN (Número d'Identificació Comercial Global)00810009715924
UPC810009715924
Tipus de producteCarregador DC-DC
Components inclososJapanese Instruction Manual, DC-DC Charger Unit

8. Vídeo oficial del producte

This video provides a visual guide on how to install and connect the Renogy DC-DC MPPT Charger, demonstrating connections to a starter battery, a lithium house battery, and a solar panel. It also covers setting battery types and understanding LED indicators for charging status.

9. Garantia i Suport

Aquest producte ve amb un Garantia del fabricant de 1 anys.

For any questions or support regarding your Renogy DC-DC Charger, please contact our customer service team:

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.