Gre SCGPHP60

Gre SCGPHP60 Salt Electrolysis Chlorinator with pH Controller and Dosing Pump User Manual

1. Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Gre SCGPHP60 Salt Electrolysis Chlorinator with pH Controller and Dosing Pump. This integrated system is designed to simplify pool water treatment by generating natural chlorine from salt and automatically regulating pH levels, suitable for pools up to 60 m³.

2. Informació de seguretat

Please read all safety warnings and instructions carefully before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

  • Desconnecteu sempre l'alimentació abans de realitzar qualsevol manteniment o servei.
  • Assegureu-vos d'una connexió elèctrica a terra adequada.
  • Keep chemicals out of reach of children and pets.
  • Utilitzeu l'equip de protecció individual (EPI) adequat quan manipuleu productes químics per a la piscina.
  • Ensure adequate ventilation in the equipment area.
  • Do not operate the system if any part is damaged.

3. Producte acabatview

The Gre SCGPHP60 system integrates three key functions for optimal pool water quality:

  • Salt Electrolysis: Produces natural chlorine from salt, eliminating the need for chemical chlorine and preventing odors or eye irritation.
  • pH Controller: Monitors and adjusts the pool's pH level automatically.
  • Bomba dosificadora: Delivers pH correction solution as needed to maintain desired levels.

This system is recommended for both above-ground and in-ground pools up to 60 m³.

Components:

  • Control Unit with integrated pH controller and dosing pump.
  • Electrolysis Cell (transparent housing with electrodes).
  • pH Probe.
  • Flow Sensor.
  • Piping and connection accessories.

4. Instruccions de configuració

Careful installation is crucial for the proper functioning of your Gre SCGPHP60 system. Follow these steps for a successful setup:

4.1. System Assembly and Plumbing

  1. Preparació de les canonades: Cut and glue the PVC pipes and fittings to create the bypass system as shown in the diagram. Ensure all connections are secure and watertight.
  2. Install Saddle Clamps: Drill holes in the main pipe for the pH probe and flow sensor. Attach the saddle clamps, ensuring the rubber gaskets are correctly seated to prevent leaks. Secure them with bolts and nuts.
  3. Install pH Probe and Flow Sensor: Carefully insert the pH probe and flow sensor into their respective saddle clamps. Tighten the connections to ensure they are firmly in place.
  4. Connect Dosing Pump Tubes: Attach the clear dosing tubes to the pH dosing pump on the control unit and to the injection point on the plumbing. Ensure the tubes are cut to the appropriate length and secured with the provided fittings.
  5. Connect Electrolysis Cell: Integrate the electrolysis cell into the bypass plumbing. Ensure the flow direction matches the arrows on the cell.
Gre SCGPHP60 control unit and chlorinator cell components

Figure 1: Gre SCGPHP60 control unit and chlorinator cell components laid out for assembly.

pH probe with cable and blue protective cap

Figure 2: pH probe with its cable and blue protective cap, ready for installation.

4.2. Connexions elèctriques

  1. Unitat de control de muntatge: Securely mount the blue control unit in a dry, protected area, preferably within a pool equipment shed.
  2. Connectar l'alimentació: Connect the main power cable to a suitable electrical outlet.
  3. Connect Cell Cables: Attach the cables from the electrolysis cell to the designated terminals on the control unit. Ensure correct polarity (red to red, yellow to yellow, etc.) and tighten the nuts securely.
  4. Connect pH Probe and Flow Sensor Cables: Plug the cables from the pH probe and flow sensor into their respective ports on the control unit.
  5. Connect Dosing Pump Power: Ensure the dosing pump is correctly connected to the control unit.
Close-up of the Gre SCGPHP60 control panel with pH display and control buttons

Figure 3: Close-up of the Gre SCGPHP60 control panel showing the pH display, power selector, salt indicator, and calibration/setting buttons.

4.3. Initial Pool Preparation

  1. Add Salt: Ensure the pool water has a salt concentration of 4 g/l (grams per liter). This is crucial for the electrolysis process. Maintain a range of 3.2 g/l to 4 g/l for optimal performance.
  2. Assegurar el flux d'aigua: The system requires a minimum water flow rate of 3 m³/h to operate correctly. Ensure your pool pump is capable of providing this flow.

4.4. Guia de vídeo d'instal·lació

Video 1: This video demonstrates the complete installation process for the Gre SCGPHP60 system, including plumbing, sensor installation, and electrical connections. It provides a visual guide to supplement the written instructions.

5. Instruccions de funcionament

Once installed, the Gre SCGPHP60 system is designed for automated operation. Here are the key aspects of its functionality:

5.1. Engegada i configuració inicial

  1. Encès: Turn on the main power to the system. The control unit will initiate a self-check.
  2. Producció de clor: The system will begin producing chlorine via salt electrolysis. The production rate can typically be adjusted via the control panel to suit your pool's needs.
  3. pH Monitoring: The pH controller will continuously monitor the pool's pH level. The current pH value will be displayed on the control unit.
  4. pH Dosing: If the pH deviates from the set point, the dosing pump will automatically inject pH correction solution (acid or base, depending on your setup and pool needs) to restore balance.

5.2. Funcions del tauler de control

  • Power Selector (ON/OFF): Activates or deactivates the system.
  • SALT Indicator: Illuminates to indicate the salt level in the pool. Refer to the specific salt level requirements in the setup section.
  • pH Display: Shows the current pH value of the pool water.
  • Botó SET: Used to enter the settings menu for adjusting parameters like desired pH level or chlorine production intensity.
  • Botó CAL: Initiates the calibration process for the pH probe.

Refer to the detailed instructions in the full product manual for specific parameter adjustments and calibration procedures.

6. Manteniment

Regular maintenance ensures the longevity and efficiency of your Gre SCGPHP60 system.

6.1. Electrolysis Cell Cleaning

The electrolysis cell may accumulate scale over time, especially in hard water areas. Regular inspection and cleaning are necessary.

  • Freqüència: Inspect the cell monthly or as recommended by the system's indicators.
  • Procediment: Disconnect power. Remove the cell from the plumbing. Clean the electrodes using a diluted acid solution (e.g., muriatic acid) or a specialized cell cleaning product, following the manufacturer's instructions. Rinse thoroughly with clean water before reinstallation.
Transparent electrolysis cell with internal electrodes

Figure 4: The transparent electrolysis cell, showing the internal electrodes that require periodic cleaning.

6.2. pH Probe Calibration

The pH probe requires periodic calibration to ensure accurate readings.

  • Freqüència: Calibrate the pH probe at the beginning of each swimming season and periodically throughout, or if readings appear inaccurate.
  • Procediment: Use certified pH calibration solutions (e.g., pH 7.0 and pH 4.0 or 10.0). Follow the calibration steps outlined in the control unit's menu using the CAL button.
Bottles of pH 7.0 and pH 4.0 calibration solutions

Figure 5: Bottles containing pH 7.0 and pH 4.0 calibration solutions, essential for accurate pH probe calibration.

6.3. Dosing Pump Tube Inspection

Regularly check the dosing pump tubes for blockages, kinks, or wear.

  • Freqüència: Inspect monthly.
  • Procediment: Ensure the tubes are clear and free of debris. Replace any worn or damaged tubes.

7. Solució De Problemes

This section addresses common issues you might encounter with your Gre SCGPHP60 system.

ProblemaCausa possibleSolució
Low or no chlorine production
  • Baix nivell de sal
  • Dirty electrolysis cell
  • Flux d'aigua insuficient
  • Configuració incorrecta
  • Check and adjust salt concentration to 4 g/l.
  • Clean the electrolysis cell as per maintenance instructions.
  • Ensure pool pump is running and providing at least 3 m³/h flow.
  • Verify chlorine production settings on the control unit.
pH level consistently high/low
  • pH probe out of calibration
  • Empty pH correction solution container
  • Dosing pump malfunction or clogged tubes
  • Incorrect pH set point
  • Calibrate the pH probe using fresh calibration solutions.
  • Refill the pH correction solution container.
  • Check dosing pump tubes for blockages and ensure the pump is operating.
  • Adjust the desired pH set point on the control unit.
El sistema no s'encén
  • Sense font d'alimentació
  • Fusible bufat / trencador trencat
  • Connexions elèctriques soltes
  • Check power outlet and cable connections.
  • Inspect fuses or circuit breakers.
  • Assegureu-vos que totes les connexions elèctriques siguin segures.

Si el problema persisteix després d'intentar aquestes solucions, poseu-vos en contacte amb l'atenció al client.

8. Especificacions

  • Número de model: SCGPHP60
  • Marca: Gre
  • Dimensions del producte (L x A x A): 19.5 x 13 x 26 cm
  • Pes de l'article: 4.06 quilos
  • Chlorine Production Capacity: 12 g/h
  • Volum de piscina recomanat: Fins a 60 m³
  • Required Salt Concentration: 3.2 - 4 g/l
  • Minimum Flow Rate: 3 m³/h
  • Energy Type: AC/DC
  • Beneficis del producte: Chlorine-free pool maintenance, pH control, reduced chemical usage.

9. Informació de la garantia

Aquest producte està cobert per una garantia del fabricant contra defectes de materials i fabricació. Els termes específics i la durada de la garantia poden variar segons la regió i el distribuïdor. Si us plau, conserveu el comprovant de compra per a reclamacions de garantia.

For detailed warranty information, refer to the documentation included with your product or contact Gre customer service.

10. Suport

If you require assistance with installation, operation, maintenance, or troubleshooting, please consult the following resources:

  • Gre Official Weblloc: Visit the official Gre website for additional resources, FAQs, and updated product information.
  • Atenció al client: Contact Gre customer support directly for personalized assistance. Contact details can typically be found on the product packaging or the official weblloc.
  • Suport al detall: Your product retailer may also offer support services.

© 2026 Gre. All rights reserved. This manual is for informational purposes only. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.