AMIR B09JBHDPH6

AMIR Indoor/Outdoor Thermometer with 3 Wireless Sensors User Manual

Model: B09JBHDPH6

1. Introducció

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your AMIR Indoor/Outdoor Thermometer with 3 Wireless Sensors. This device is designed to monitor temperature and humidity in up to four different locations simultaneously, offering clear readings on a large LCD display.

2. Informació de seguretat

  • Do not disassemble the product. Unauthorized modifications may void the warranty and cause damage.
  • If the display becomes blurry, replace the batteries promptly.
  • Avoid placing the product in hot, humid, dusty, or corrosive gas environments to prevent damage to electronic components.
  • Assegureu-vos de la polaritat correcta de les piles en inserir-les.

3. Contingut del paquet

Verifiqueu que tots els elements siguin presents al paquet:

  • 1 x AMIR Indoor/Outdoor Thermometer Main Unit
  • 3 x Wireless Thermometer-Hygrometer Transmitters
  • 1 x Manual d'usuari
  • 1 x Apple Data Cable (for main unit power)

4. Configuració

4.1 Alimentació de la unitat principal

The main unit can be powered in two ways:

  • Potència de la bateria: Insert 3 AA batteries (not included) into the battery compartment on the back of the main unit.
  • Cable Power: Plug the included Apple data cable into the main unit's charging port and connect it to a USB power source.
Image showing the main unit with its battery compartment open for 3 AA batteries and a lightning cable connected for power.

Figure 1: Main unit power supply options (battery and cable).

4.2 Setting Up Wireless Sensors

The three wireless transmitters are identical. To differentiate them and ensure proper connection:

  1. On the back cover of each transmitter, locate the channel dial and set it to 1, 2, or 3 for each respective sensor.
  2. Insert 2 AAA batteries (not included) into each transmitter. The indicator light on the transmitter will flash red, signaling it is attempting to connect.
  3. The main unit will automatically connect to the transmitters. If a sensor does not connect immediately, it will attempt to reconnect in approximately 60-second cycles. To expedite the connection, remove and reinsert the batteries in the transmitter and wait for the red light to flash.
Image showing the main thermometer unit and three wireless sensors, indicating their placement in different rooms like a bedroom, living room, and greenhouse.

Figure 2: Main unit and three wireless sensors for multi-location monitoring.

Vídeo 1: Acabatview of the AMIR Indoor Outdoor Thermometer, demonstrating its features and setup process.

5. Instruccions de funcionament

5.1 Large LCD Display and Backlight

The main unit features a 4.6-inch large LCD display for clear and simple readings. To activate the backlight, press the 'LIGHT' button on the right side of the unit. The backlight has one level when battery-powered and two levels when cable-powered.

Image showing a finger pressing the 'LIGHT' button on the main unit, illuminating the large LCD screen for easy reading in the dark.

Figure 3: Activating the LCD backlight for improved visibility.

5.2 Selecció de la unitat de temperatura (°C/°F)

To switch between Celsius (°C) and Fahrenheit (°F), press the '°C/°F' button located on the right side of the main unit.

5.3 MAX/MIN Record

The thermo-hygrometer records the maximum and minimum temperature and humidity values over the past 24 hours. Press the 'MIN/MAX' button on the left side of the unit to cycle through current, maximum, and minimum readings.

5.4 Air Comfort Indicator

The display includes an air comfort indicator to quickly assess indoor conditions:

  • SEC: Humitat < 40%
  • COM (Comfort): 40% < Humitat < 70%
  • MÚLID: Humitat > 70%
Image illustrating the Air Comfort Indicator with icons for DRY (humidity less than 40%), COM (humidity between 40% and 70%), and WET (humidity greater than 70%).

Figure 4: Air Comfort Indicator for quick environmental assessment.

5.5 Low Battery Reminder

The unit will display a low battery icon when the main unit's battery voltage drops below 3.6V or the transmitters' battery voltage drops below 2.7V. Replace batteries promptly to ensure continuous operation.

Image showing the main unit and a wireless sensor with low battery icons, indicating when to replace batteries.

Figure 5: Low battery reminder on the main unit and transmitters.

6. Opcions de muntatge

Both the main unit and the wireless transmitters offer flexible mounting options:

6.1 Main Unit Mounting

  • Vertical: Use the integrated stand to place the unit on a tabletop or desk.
  • Muntatge en paret: Utilize the hanging hole on the back to mount it on a wall.
  • Esquena magnètica: The unit has a magnetic back for attachment to metallic surfaces like refrigerators.

6.2 Muntatge del transmissor

  • Vertical: Place the transmitter on a flat surface.
  • Muntatge en paret: Use the hanging hole for wall mounting.
  • Lanyard/Suction Cup: The transmitter comes with a lanyard and suction cup for versatile placement, such as hanging or attaching to glass.
Image displaying various mounting options for both the main unit (stand, wall mount, magnetic back) and the wireless sensors (stand, wall mount, lanyard with suction cup).

Figure 6: Multiple mounting options for the main unit and wireless sensors.

7. Manteniment

7.1 Substitució de la bateria

Replace batteries in the main unit (3 AA) and transmitters (2 AAA each) when the low battery indicator appears on the display. Always use new batteries and ensure correct polarity.

7.2 Neteja

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.

7.3 Consideracions ambientals

To prolong the life and accuracy of your device, avoid exposing it to:

  • Llum solar directa o fonts de calor extremes.
  • High humidity or direct water exposure.
  • Excessive dust or corrosive gases.

8. Solució De Problemes

8.1 El sensor no es connecta

  • Ensure batteries are correctly inserted and have sufficient charge in both the main unit and the sensor.
  • Verify that the sensor's channel dial is set to a unique number (1, 2, or 3).
  • Move the sensor closer to the main unit to check if it's a range issue. The maximum range is 100m/328ft in open air, but obstacles like walls can reduce this.
  • Remove and reinsert the batteries in the problematic sensor to force a reconnection attempt.

8.2 Blurring Display

A blurring display typically indicates low battery power. Replace the batteries in the main unit.

8.3 Lectures inexactes

  • Ensure sensors are not placed in direct sunlight or near heat/cold sources, which can skew readings.
  • Allow the main unit and sensors to stabilize in their respective environments for at least 30 minutes after setup for accurate readings.
  • Compare readings with another known accurate thermometer/hygrometer if possible.

9. Especificacions

CaracterísticaEspecificació
Rang de temperatura interior-20°C to 70°C (0°F to 60°C in some specifications)
Interval de temperatura exterior-50 °C a 70 °C
Gamma d’humitatdel 10% al 99%
Precisió de la temperatura±1 °C (±2 °F)
Precisió de la humitat±5%
Freqüència de transmissió sense fil433 MHz
Distància de transmissió sense filsFins a 100 m (328 peus) a l'aire lliure
Potència de la unitat principal3 x AA batteries (not included) or Apple data cable (included)
Potència del transmissor2 piles AAA (no incloses) per sensor
Dimensions de la unitat principal11.8 x 11.2 x 2.5 cm (approx. 4.65"W x 4.41"H)
Dimensions del transmissor8.3 x 5 x 2 cm

10. Garantia i Suport

AMIR products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official AMIR weblloc web. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.

Ask a question about this manual