Thank you for choosing the Orbit 58085N Hose Y with Shut-Off. This device allows you to split a single outdoor faucet into two independent water sources, each with its own shut-off valve. This manual provides essential information for the proper installation, operation, and maintenance of your new hose Y to ensure long-lasting and efficient performance.

Informació de seguretat

  • Always ensure all connections are tight to prevent leaks and water waste.
  • Do not overtighten connections, as this can damage threads on the hose Y or your faucet.
  • Turn off the main water supply to the faucet before installing or removing the hose Y.
  • In freezing conditions, disconnect the hose Y and store it indoors to prevent damage from ice expansion.
  • This product is designed for outdoor use with water only. Do not use with other liquids or for purposes other than its intended use.

Contingut del paquet

Your Orbit 58085N package should contain the following:

  • Orbit 58085N Hose Y with Shut-Off (Quantity as purchased, e.g., 5 units for a 5-pack)

Instruccions de configuració

  1. Prepareu l'aixeta: Ensure your outdoor faucet (spigot) is clean and free of debris. Turn off the water supply to the faucet.
  2. Attach the Hose Y: Screw the female connector of the Orbit 58085N Hose Y onto your outdoor faucet. Hand-tighten until snug. If a leak occurs, unscrew, apply PTFE (Teflon) tape to the faucet threads, and re-tighten. Do not use tools to overtighten, as this can strip threads or crack the plastic.
  3. Connecteu les mànegues: Attach your garden hoses to the two male outlets of the hose Y. Hand-tighten each hose connection. Ensure a rubber washer is present in each hose coupling for a watertight seal.
  4. Prova de connexions: Slowly turn on the water supply to your faucet. Check all connections for leaks. If leaks occur, tighten the connection slightly or re-apply PTFE tape if necessary.
Orbit 58085N Hose Y attached to an outdoor faucet with two hoses connected.
Figure 1: The Orbit 58085N Hose Y connected to a faucet, ready for hose attachment. This image illustrates the primary connection point to your water source.

Instruccions de funcionament

The Orbit 58085N Hose Y features two independent shut-off valves, allowing you to control water flow to each connected hose separately.

  • Obrir l'aigua: To open a valve, rotate the lever handle 90 degrees so it is aligned with the hose outlet.
  • Tancar l'aigua: To close a valve, rotate the lever handle 90 degrees so it is perpendicular to the hose outlet.
  • You can operate one valve independently while the other remains open or closed, providing flexible water management.
Close-up of the Orbit 58085N Hose Y shut-off valves in open and closed positions.
Figure 2: Detail of the individual shut-off valves. The green levers control water flow to each outlet.

Manteniment

  • Neteja: Periodically inspect the hose Y for dirt or mineral buildup, especially around the threads and inside the outlets. Clean with a soft brush and water if necessary.
  • Prevenció de fuites: If leaks occur, check the rubber washers in your hoses and the connection to the faucet. Replace worn washers as needed. Applying PTFE (Teflon) tape to metal threads can also help create a better seal.
  • Hivernització: Before the first freeze, disconnect the Orbit 58085N Hose Y from the faucet and drain any remaining water. Store it indoors in a dry, protected area to prevent freezing and potential damage to the plastic components.

Resolució de problemes

ProblemaCausa possibleSolució
Fuita aigua per la connexió de l'aixeta.Loose connection, damaged faucet threads, no PTFE tape.Tighten connection. Apply PTFE tape to faucet threads. Inspect faucet threads for damage.
Fuita d'aigua per la connexió de la mànega.Loose connection, missing or worn rubber washer in hose.Tighten hose connection. Ensure a rubber washer is present and in good condition; replace if necessary.
Low water flow from an outlet.Valve not fully open, debris in the hose Y or hose.Ensure the valve lever is fully aligned with the hose outlet. Disconnect hoses and check for obstructions in the hose Y and hoses.
Valve lever is stiff or stuck.Mineral buildup, internal component issue.Try gently wiggling the lever. If persistent, disconnect and flush with water. If still stuck, replacement may be necessary.

Especificacions

  • Número de model: 58085 N
  • Material: Plàstic durador
  • Color: Verd
  • Tipus de connector: Hose Y
  • Tipus de fil: NPT (National Pipe Taper)
  • Dimensions de l'article (L x A x A): 1.75 x 4 x 5.63 polzades (aproximadament)
  • Nombre de punts de venda: 2 (with independent shut-off valves)

Informació de la garantia

Orbit products are manufactured to high-quality standards. For specific warranty details, please refer to the packaging of your product or visit the official Orbit weblloc web. Conserveu el rebut de compra com a comprovant de compra per a qualsevol reclamació de garantia.

Suport

Per a més ajuda, informació sobre el producte o per a view other Orbit products, please visit the official Orbit weblloc:

www.orbitanline.com

You may also contact Orbit customer service through the contact information provided on their weblloc.

© 2023 Orbit. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.