Thank you for choosing the ApooDr 12000 BTU Mini Split Air Conditioner Ductless Inverter System. This unit provides efficient cooling and heating for spaces up to 550 sq ft, featuring advanced inverter technology for energy savings and quiet operation. This manual provides essential information for the safe and effective installation, operation, and maintenance of your new air conditioning system.

Image 1: ApooDr 12000 BTU Mini Split Air Conditioner system components.
2. Informació de seguretat
Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or death.
- Instal·lació professional necessària: This unit requires professional installation by a qualified HVAC technician to ensure proper function and safety. Improper installation can lead to refrigerant leaks, electrical shock, or fire.
- Seguretat elèctrica: Ensure the power supply matches the unit's requirements (110V/60Hz). Do not operate the unit with damaged power cords or plugs. Always disconnect power before performing any maintenance or repairs.
- Manipulació de refrigerants: This unit contains R-410A refrigerant. Only qualified personnel should handle refrigerant. Do not vent refrigerant into the atmosphere.
- Liquidacions: Mantingueu una distància adequada al voltant de les unitats interiors i exteriors per a un flux d'aire i un manteniment adequats.
- Nens i animals de companyia: Mantingueu els nens i les mascotes allunyats de la unitat, especialment durant el funcionament i el manteniment.
3. Contingut del paquet
Verify that all components are present and undamaged upon unpacking. If any items are missing or damaged, contact your retailer or ApooDr customer support immediately.
- Unitat interior
- Unitat exterior (condensador)
- Backlit LCD Remote Control
- Fils de comunicació
- Pre-flared, Insulated Copper Line Set (approximately 16 feet)
- Installation Kit (includes various accessories for mounting and connection)

Image 2: All components included in the ApooDr Mini Split system package.
4. Configuració i instal·lació
Important: Installation of this mini split system requires specialized tools and knowledge. It is strongly recommended that installation be performed by a certified HVAC professional to ensure compliance with local codes, proper operation, and to maintain warranty validity.
4.1 Consideracions clau per a la instal·lació
- Ubicació: Select appropriate locations for both the indoor and outdoor units, ensuring adequate space for airflow, drainage, and maintenance.
- Connexió elèctrica: The unit operates on 110V/60Hz. Ensure a dedicated circuit with appropriate ampera disponible.
- Línies de refrigeració: The system comes pre-charged with R-410A refrigerant. The included pre-flared line set simplifies connection, but proper vacuuming and leak testing are crucial.
- Drenatge: Ensure proper condensate drainage for the indoor unit to prevent water damage.

Image 3: ApooDr Mini Split outdoor unit.
5. Instruccions de funcionament
Your ApooDr Mini Split system offers multiple operating modes and features for optimal comfort, controlled via the included backlit LCD remote.
5.1 Modes de funcionament
Premeu el botó MODE button on the remote to cycle through the following options:
- Mode automàtic: The unit automatically selects cooling or heating based on the set temperature and ambient room temperature.
- Mode fresc: Provides cooling operation. Adjustable temperature range: 62°F to 90°F (17°C to 32°C).
- Mode de calor: Provides heating operation. Adjustable temperature range: 32°F to 86°F (0°C to 30°C).
- Mode sec (deshumidificació): Redueix la humitat a l'habitació sense canvis significatius de temperatura.
- Mode de ventilador: Fa circular l'aire sense refredar ni escalfar. La velocitat del ventilador és ajustable.

Image 4: ApooDr Mini Split indoor unit displaying operating modes.
5.2 Funcions de control remot
The backlit LCD remote allows full control over your system. Refer to the remote control diagram for button layout.
- ON/OFF: Encén o apaga la unitat.
- TEMP ▲/▼: Adjusts the set temperature.
- VENTILADOR: Canvia la velocitat del ventilador (Automàtic, Baixa, Mitjana, Alta).
- SWING: Controls the louver's vertical swing.
- DORMIR: Activates sleep mode for reduced noise and energy consumption during sleep.
- TEMPORIZADOR ON/OFF: Sets a timer for the unit to turn on or off automatically.
- LED: Turns the indoor unit's display LED on or off.
- NETEJA: Initiates a self-cleaning function for the indoor coil.
- TURBO: Activates maximum cooling or heating for rapid temperature change.

Image 5: ApooDr Mini Split backlit LCD remote control.
5.3 Característiques especials
- Intelligent Defrost: Automatically defrosts the outdoor unit's coil in heating mode when ice buildup is detected, ensuring efficient operation.
- Preescalfament: In heating mode, the indoor fan will not start until the indoor coil has warmed up, preventing cold drafts.
- Autodiagnòstic: The system can detect and display certain operational errors via error codes on the indoor unit's LED display.
6. Manteniment
Regular maintenance ensures optimal performance and longevity of your ApooDr Mini Split system.
6.1 Neteja del filtre d'aire
The indoor unit is equipped with a permanently washable and easy-to-clean air filter. Clean the filter regularly (every 2-4 weeks, depending on usage) to maintain air quality and system efficiency.
- Apagueu la unitat i desconnecteu l'alimentació.
- Obriu el panell frontal de la unitat interior.
- Traieu els filtres d'aire.
- Renteu els filtres amb aigua tèbia i un detergent suau. Esbandiu-los bé.
- Allow the filters to air dry completely before reinstalling. Do not expose to direct sunlight or heat.
- Torneu a instal·lar els filtres secs i tanqueu el panell frontal.
6.2 Manteniment de la unitat exterior
Periodically inspect the outdoor unit for debris (leaves, dirt) that may obstruct airflow. Gently clean the coils with a soft brush or vacuum. Ensure the area around the outdoor unit remains clear.
6.3 Servei professional
It is recommended to have a qualified HVAC technician perform an annual inspection and service of your system, including checking refrigerant levels, electrical connections, and drainage.
7. Solució De Problemes
This section addresses common issues you might encounter. For complex problems or error codes not listed, please contact professional service.
| Problema | Causa possible | Solució |
|---|---|---|
| La unitat no s'encén | No power; Remote control batteries low; Circuit breaker tripped. | Check power supply; Replace remote batteries; Reset circuit breaker. |
| Refrigeració/calefacció insuficient | Dirty air filter; Doors/windows open; Temperature setting incorrect; Outdoor unit obstructed; Low refrigerant. | Clean air filter; Close doors/windows; Adjust temperature; Clear obstructions; Contact service for refrigerant check. |
| Soroll inusual | Loose parts; Fan obstruction; Normal operating sounds (e.g., refrigerant flow). | Inspect for loose parts; Remove obstructions; If noise is excessive or unusual, contact service. |
| Error Code PC 04 | Communication error between indoor and outdoor units. | This indicates a serious communication issue. Immediately contact a qualified HVAC technician for diagnosis and repair. Do not attempt to fix this yourself. |
8. Especificacions
Key technical specifications for the ApooDr 12000 BTU Mini Split Air Conditioner.
| Característica | Especificació |
|---|---|
| Marca | ApooDr |
| Número de model | ASF16-12H1B |
| Capacitat | 12000 BTU (1 tones) |
| Classificació SEER2 | 17.4 |
| Classificació HSPF2 | 8.7 |
| Voltage | 110V/115V, 60Hz |
| Nivell de soroll (interior) | 27.5 dB |
| Àrea de cobertura | Fins a 550 peus quadrats |
| Refrigerant | R-410A (Pre-charged) |
| Dimensions de la unitat interior (P x A x A) | 7.64" x 31.69" x 11.22" |
| Pes de l'article | 89 lliures (sistema total) |
| Certificacions | AHRI Certified, UL Certified |

Image 6: EnergyGuide label for ApooDr ASF16-12H1B.
9. Garantia i Suport
ApooDr stands behind the quality of its products. Your Mini Split Air Conditioner comes with the following warranty:
- Compressor: 5 any de garantia
- Parts: 2 any de garantia
Please retain your proof of purchase for warranty claims. Professional installation is required to validate the warranty.
Atenció al client